Download | Size: 6 MB 19th Jul 2013 DLE2515 LG Electric Dryer Repair Service Manual .PDF
717808 Downloads
7.95 MB .pdf
25 • Door switch Check (Refer to Component testing. Control Panel & Plate Assembly A210 A120 A130 A110 37 12-2. • Drum Belt cuts off • Drum Belt takes off from • Motor Pulley. Disconnect the Air duct from the Tub Drum [Front]. 613mm, for Propane Gas) Replace Label Instruction Sheet Orifice 28 GAS VALVE FLOW START KEY PUSH VALVE 1 ON IGNITER ON IGNITER TEMPERATURE ABOUT 370°F NO YES FLAME DETECT OPEN IGNITER OFF VALVE 2 ON GAS IGNITION NO FLAME DETECT CLOSE YES DRYING VALVE 2 OFF GAS IGNITION GAS VALVE STRUCTURE Adjustment Screw START VALVE 1 ON IGNITER ON OFF FLAME DETECT CLOSE OPEN OFF ON VALVE 2 GAS IGNITION 29 11 DISASSEMBLY INSTRUCTIONS Disassemble and repair the unit only after pulling out power plug from the outlet. Igniter Measure resistance of terminal to terminal 12. Drum & Motor Assembly: Electric Type F200 K400 K120 K140 K100 K130 K250 K251 K310 K330 K320 K340 K221 K620 K230 K210 K250 K360 K350 K610 K550 K560 K251 K240 K530 F140 K651 K510 K540 K520 K640 F130 K650 F110 K600 F120 39 12-3-2. Heater Test Procedure Measure resistance of the following terminal Terminal: 1 (COM) - 2 Terminal: 1 (COM) - 3 Terminal: 2 - 3 8. Use the instructions under option 1 if your home homehas a 4-wire receptacle (NEMA type 14-30R). Gas Connection 12 4 DRYER CYCLE PROCESS Default Cycle Sensor Dry * Manual Dry ** Conditions of operation and termination Drying Cooling Temp- Dry Display erature Level time Electro- Temp- Default Tempsensor Control time Control** COTTON/ TOWELS MID (Normal) 55min Saturation 66±4°C (5min) 47±5°C HIGH NORMAL MEDIUM (Normal) 41min Saturation 60±4°C (5min) 47±5°C DELICATES LOW SPEED DRY (HIGH) Wrinkle care Time 3Hr (Normal) 32min Saturation 52±3°C (5min) 38±5°C - 25min Saturation (70±5°C) (5min) (47±5°C) 3Hr AIR DRY - - 30min Saturation No heater N/A N/A Off Time: 6min Motor Load Temperature Control for each cycle Heater * Sensor dry: “Dry Level” is set by users. The display number is below 180, in normal condition. 5kΩ? YES (Measure after Off ) • Change Valve NO If “Valve 1 “ and “Valve 2” are under DC 10V, Valves NO are Off? YES • Harness check • Controller change 27 • Change Valve 10 ! CHANGE GAS SETTING (NATURAL GAS, PROPANE GAS) Warning Changing orifices and gas valve adjustments improperly can result in an explosion and/or fire. (Refer to ‘Motor Diagram & Check’) • Check if Control Connector is contacted. NOTE: That the Pedestal hardware packet may include 2 sets of side brackets. Connect the other two power cord wires (red and black) to the left and right terminal block screws and tighten securely. 2 22 Test 3 Motor test Caution Before measuring resistance, be sure to turn Power off, and do voltage discharge. 5A) AC 240V (ELECTRIC MODEL) LAMP 15 W (125mA) AC 120V 13 W (110mA) x 2 AC 120V (GAS MODEL) GAS VALVE CONTROL TYPE Electronic DRUM CAPACITY 7. Outlet Thermostat ( Auto reset) • Check Top Marking: N85 Test Procedure Remark Measure resistance of terminal If thermal fuse is open must • Heater caseto terminal be replaced Safety ± • Electric type Open at 266 12°F Resistance value ≒ ∞ ± (130 7°C) Auto reset 31°F (35°C) Continuity (250°F ) < 1Ω Same shape as Outlet Thermostat. ) See test 3 70 ~ 239 20 Lamp • Press Start button 1 time and then open the door. ESD may damage or weaken the electronic control assembly