Download Reliable Power Meters Power Recorder .PDF
6372893 Downloads
4.26 MB .pdf
4MB cache A -D impulse logic >4 kHz Hard disk Optional transient capture system uses a 10-bit 2 MS/s A-to-D converter to capture transients up to 6400V and as fast as 500ns Power Recorder Architecture RMS and transient data are synchronized in cache memory and stored in database on hard drive Full Disclosure technology lets you plot events on any power tolerance curve. 7 kS/s depending upon line frequency Voltage and current rms measurements: Processed for every full cycle Power Measurements: W, VA, VAR, PF, dPF processed for very full cycle Impulse measurements (Standard-speed unit with option 1651) Function Range Resolution Sampling rate 6. (6 Kg) Operating temperature: 0 ° - 50 °C (32 ° - 122 °F), 90% RH non-condensing Standards UL3111 IEC 868 Configuration Installable Options Me as ur em en Ha ts rm on ics Po we rC on su Im mp pu tio lse n W av efo Mu rm lti -S es sio TC n So P/ ftw IP St ar ac e k Safety: 600 V CAT III Operating voltages: 85-264 VAC, 47 - 440 Hz; 10 - 15 V DC with 4250 or 4255 optional cable Power consumption: 40 watts Batteries: NiCd battery recharges automatically while line power is applied. • The sampling system processes every cycle on all channels, recording min/max/avg values and looking for sags, swells, or transients. Polling and Alarms software allows you to configure and monitor multiple instruments, retrieve data periodically, and set up alarms to notify operators of events. Both packages handle seamless communication with the Power Recorder, graphical display of power system parameters, and data management tools. Specifications Number of channels: 9 (4 voltage, 5 current) Accuracy ±(% of reading + floor) Function Range Resolution Voltage (phases) 100 mV - 600 Vrms 1000 V peak impulse 14 bits, 90 millivolts ± (1. com 4 Reliable Power Meters Power Recorder ©2005 Reliable Power Meters. Reliable Power Meters Power Recorder Full Disclosure™ monitoring for the most comprehensive power quality studies Technical Data Every measurement, every event, on every cycle, all the time – without thresholds Full Disclosure Technology is part of all Fluke and RPM three-phase power quality tools. With 1653 option, you can display harmonics up to the 63rd as a spectrum or table. 1 Hz Voltage and current sampling: 128 samples per cycle on 50/60 Hz Voltage and current sampling rate: 6. Power Recorders are configurable, so you can expand their capabilities to meet your growing needs. With 1652 option, real-time meter and vector diagram displays Watts, VA, VAR , PF and dPF. The Power Quality Index allows you to trend system performance over time and determine whether a system is improving or degrading. Measurement Features All Power Recorders 1652 Power Consumption Option 1653 Harmonics Option 1651 Power Quality Option 1658 High Speed Power Quality Option 1662 Multi-Session Option 1663 TCP/IP Option • Logging RMS voltage and RMS current on all channels • Phasor diagrams • Frequency trends • Real-time oscilloscope display of voltage and current on all channels • Watts and demand trends • KWH, individual phases and total • VA and VAR trends • Power Factor trends, true and displacement • Oscilloscope display of power meters for each phase • Voltage and current THD trends • Voltage and current imbalance • Harmonic spectrum, phase, magnitude to 63rd harmonic • Tracking of individual harmonics • Voltage waveshape faults as short as 130 µs duration, 1000 V peak • Voltage sags/swells • Simulations current corresponding to correlated with voltage events • Power tolerance curves • Voltage and current waveshape faults • Voltage and current sags/swells • Power tolerance curves • Transients as short as 500 ns duration, 6400 V peak; with peak detect or detailed waveform graphs • Allows a recorder to store up to 16 measurement sessions • Each session can consist of up to 6000 events, increasing the event storage to 96,000 • Enables Ethernet-equipped instruments to communicate via Internet Software completes the system There are two software packages available for the Power Recorder. • Because there are no thresholds to set, Full Disclosure technology system records any changes in measurements, even the ones that are almost out of tolerance 14 bit, 7. You can see everything from subcycle events to long-term outages with clear detail. The Power Analyzer System software package • Offers optional Report Writer Software • Offers Alarming and Polling Option Scenario Software • Allows plotting multiple measurement sessions on one timescale • Includes facilities for comparing trends from multiple databases • Calculates a Power Quality Index - a single figure of merit that characterizes the overall performance of a power system. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www. Model Number Enclosure Computer Interface Sampling System 1650-56 Standard Ethernet High-speed included 1650-50 Standard Ethernet Standard 1650-15 Hostile Ethernet High-speed 1650-51 Hostile Ethernet Standard PQ Electrical 1651 1652 1653 1658 1662 1663 • • • • • • • • • • • • • • • • • • • • • Accessories 4001 Carry Bag, W/Rpm Logo 4003 Shipping Caddy With Wheels 4005 Shipping Container, Reusable 4006 6 Ft Steel Lockable Security Cable 4008 Monitor Brackets for Wall-Mounting 4250 DC Power Cable, Hostile Environment Enclosure 4255 DC Power Cable, Standard Enclosure Included accessories 3014R 40 Amp Clamp All units include user manual, line cord, 5 voltage leads and 5 alligator clips