Download ExBin-FR… Frost protection thermostat .PDF
550792 Downloads
4.20 MB .pdf
06_en 16-Jul-2015 Schischek GmbH Germany, Mühlsteig 45, Gewerbegebiet Süd 5, 90579 Langenzenn, Tel. For electrical connection use the internal approved Ex-e junction box. Highest protection class (ATEX) and IP66 protection, small dimension, universal functions and technical data guarantee safe operation even under difficult environmental conditions. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected] www. 06_en 16-Jul-2015 Schischek GmbH Germany, Mühlsteig 45, Gewerbegebiet Süd 5, 90579 Langenzenn, Tel. Long cabeling For using long signal wires, shilded cables are recommended. -CT = version in Amercoat, marine painting, seawater-resistant) L × W × H = 180 × 107 × 66 mm / ~ 950 g Maintenance free, nevertheless maintenance must be complied with regional standards, rules and regulations Storage temperature −20…+50 °C, capillary’s max. The electrical wiring must be realized via integrated Ex-e junction box in acc. If supply voltage 24 VAC/DC different from the relay voltage must be used different or double isolated cables. temperature +80 °C, operation temperature: [switching point]. Nevertheless maintenace must comply with regional standards, rules and regulations. Separate ground wires Use for supply and signal wires a separate ground. com 1/3 ExBin-FR… E X P L O S I O N P R O O F Technical data Power supply Current, power consumption Galvanic isolation Electrical connection Cable entry Protection class Display Housing protection Housing material Dimension / weight Maintenance Temperature range 24 VAC/DC ± 20 % (19,2…28,8 VAC/DC) 50…60 Hz 150 mA, ~ 4 W, internal fuse 500 mAT, without bracket, not removable Supply – output 1,5 kV Terminals 0,14…2,5 mm² at integrated Ex-e junction box 2 × M16 × 1,5 mm Ex-e approved, cable diameter ~ Ø 5…10 mm (. All others use separate or double isolated cables. IP66 - For outdoor installation a protective housing against rain, snow and sun should be applied - Do not crack the capillary (notice minimum capillary bending radius) - For electrical connection use the integrated junction box Ex-e Important information for installation and operation Installation, Commissioning, Maintenance The cable has to be drawn through the cable gland. 06_en 16-Jul-2015 Schischek GmbH Germany, Mühlsteig 45, Gewerbegebiet Süd 5, 90579 Langenzenn, Tel. The supply has to be connected at terminal 1 (−/~) and 2 (+/~). Output switch Potential free switching contact Ratings load max. 10 mW / 0,1 V / 1 mA Mechanical life 10 × 106 Electrical life (rated load) Wiring diagram (SB) Installation sensor / tubing 100 × 103 SB 1. with operation ExBin switches are maintenance free