Atari file - ALLTRONIC snc
Download Atari file - ALLTRONIC snc .PDF
3182886 Downloads
7.80 MB .pdf
- By request it is possible to deliver the "Accordion-type gate" version (D4): an opening block of the motor when something is crossing the range of action of the photocell, and continuation of the movement with photocell free. This control will be protected in all its parts by the law. It is advisable to overhaul the relay contacts every 4 years, but always according to the following conditions : - Single-phase controls type CN90P1 - CN91 - CN93 - CN94 - CN96 - CN80 Max. - By selecting on special Dip-switches, you could obtain the following kinds of working: Dp 1 : ON = with obstructed photocell the gate does not open Dp 2 : ON OFF = step-by-step (semiautomatic) system = automatic system Dp 3 : ON = gate block by giving an impulse when opening (open, block, close, open etc. Remember that all installations have to be carried out according to law requirements and the rules of good installation. INSTALLATION ADVICES : 1) The control should be installed as near the gate as possible. - The control gives opening movement, but the motor closes. "Logica" card adjustments P1 = P2 = L1 = L2 = L3 = L4 = Sw1= D15= "Working time" trimmer (from 6 to 75 sec. - For best connections, align the photocells, than make the other connections. - Remember that if some tension is taken off from the control, the first movement after reset will be an opening. D4 = By connecting the 1N4148 diode you can have the "Accordion-type gate" working (with obstructed photocell the gate stops when opening, while reverses when closing). button input to OPEN - CLOSE 9 -10 = Output at 24V dc. ) Led signalling pressed opening button (red) Led signalling supplied unit (green) Led signalling open block (yellow) Led signalling obstructed photocell (yellow) Dip-switch to preselect fonctions (see directions on the previous page) By taking off this diode, you could have the "Condominiale" working (the button is only to open; the closing is automatic). - When using the control with "Condominiale" working (by cutting off the D15 diode), remember to put the Dip-switch on AUTOMATIC, otherwise the control doesn’t close! NOTE: Before opening the control for maintenance service, you should connect an omnipower switch, with a minimum contact opening distance of 3 mm, on the control to switch it off (CEI 64-8). - Input of open/close in short-circuit (lit L1 red led). Alltronic snc states that the model CN91 has been registered. will not be responsible for wrong connections and/or mishandlings of the controls which will not be considered under guarantee. 000 - Three-phase controls type CN95 - CN98 - CN99 Max. With the gate open, the pause timer (which can also be bypassed by pressing the open/close button once again) will reclose as determined by the special trimmer. ) "Pause time" trimmer (from 3 to 75 sec