Installation in a rising pipe is recommended (in which the direction of flow is upward) ·· Note the inlet and outlet dimensions (see drawing DN = pipe cross section) , 2x 3. 20 s ·· Then the flow rate is displayed as a % of the measuring range ·· The switch output is adjusted according to the set value Electrical connection FKS-141 2. 32 V DC 2: Not assigned 3: 0 V supply voltage (GND) 4: Switch output active 2x , 2x press within 10 s ·· Main menu level “SP” (switch point setting) appears on the indicator ·· Navigation in the menu field: ·· to the right, ·· upward, changing the values ·· to the left, accepting the new parameter settings, leaving the operating mode Mechanical connection/Installation ·· Attention: The M12 plug must face in the direction of the pipe against the direction of flow. ·· You have to guarantee the compliance of all guidelines applicable for the entire equipement. Intended use Standards and guidelines ·· Not suitable for applications in potentially explosive areas. 0 / 2015-02-16 / MU / EU NEGELE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33 . When the medium is stationary, a constant temperature difference ∆T arises between the heated and unheated state. The response time is also significantly influenced by the heat conductivity of the medium. In general, the lower the heat conductivity of the medium, the higher the medium flow rate must be for measurement to be possible. ·· Compliance with the applicable regulations and directives is mandatory. Temperature Heating current Specification FOOD Specification Process connection thread tightening torque G1/2" on sensor, combined with Negele weld-in sleeves max. Setting the switch output ·· Default setting: normally open contact ·· If the normally closed function is to be set, proceed as follows: Direction of flow ·· In the main menu level, select “O-C” with ·· Open the editing mode with , ; the indicator shows “n. 100 % 10 % Indicator 7 segment red LED in % of measuring range output switching state Electrical connection cable connector supply voltage current consumption M12 connector 1. Gases, oils and media containing oil cannot be measured with the FKS. 200 mA *) Reference conditions in case of laminar flow profiles: calibration medium is water at ambient temperature. short circuit proof and protected against reverse polarity, max. Notice Flow monitor FKS-141 has an integrated self-protection mechanism that prevents damage: At medium temperatures over 100 °C, the sensor is automatically switched off with a hysteresis of 10 K. 80 °C to 100 °C to 130 °C (no function) Operating pressure max. 10 bar Protection class IP 69 K Measuring range 15. , as dry-run protection or for monitoring filters, agitators or cooling loops · Also suitable for highly pure, aqueous media without particles or solids (e