- Condensation collection bowl not in contact with compressor. 15 English 27 EN FAULT F1 CAUSE Compressor relay sticking CORRECTIVE ACTIONS - Check for water leaks that may affect connector J1 causing the relative contacts to short; - Check motor terminal board (possible problems due to incorrect connection which may cause short-circuits); - Renew motor; - Renew PCB. Appliance Powered led which lights up automatically when the appliance is connected to the power supply. 3 SUPER FREEZE BUTTON: The Super Freeze button is used for activating/ deactivating the Super Freeze function for 24 / 48 hours for static appliances and for 24 hours for No Frost appliances. For the defrosting characteristics/procedure, consult the Indesit New Cold Platform manual. 2 SWITCHING THE FRIDGE COMPARTMENT ON/ OFF: The fridge compartment switches on automatically when the appliance is switched on (see previous paragraph). switches off and the relative drawer can be used as an additional standard freezer drawer. AUTOTEST in appliances with TOUCH interface: To activate the AUTOTEST procedure, turn the appliance off (On/Off button) and press the following buttons at the same time for six seconds: Super Cool + Super Freeze + Ice Party. In the event of a power failure, when power is restored the appliance will continue in DEMO mode. 5 PRODUCT CHARACTERISTICS: SURROUND: OPERATING LOGIC The innovative SURROUND refrigeration system featured on all Ariston Full No Frost refrigerators guarantees a uniform temperature throughout the refrigeration compartment thanks to numerous ventilation cells. Super Fridge (Ever Fresh) led which lights up when the user activates the Super Fridge function or, on some models (where featured), lights up when the user activates the Ever Fresh function. 15 English 9 EN To activate the Super Fridge function, press the relative button, the corresponding Led will light up to signal activation. F22 - Check efficiency of contacts on connector J11 on the PCB; - Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of FRIDGE Air NTC probe open / wiring connector J11 is compatible with the values in the temperature-impedance correlation table (also heat the probe by holding it with your hand where short circuit possible and checking the change in the impedance value); - Renew main PCB. Service Manual Edition Language NEW ARISTON 60 cm PLATFORM 2006. - Check that the compressor is not stopped due to overtemperature conditions (thermal cutout open) - Renew motor; - Renew PCB. 6 APPLIANCE SPECIAL FUNCTIONS HOLIDAY Function: For details of this function, see the Indesit New Electronic Cold Platform manual. The function terminates automatically after 255 seconds. FREEZER DOOR-ARISTON STAINLESS STEEL 592X803X71 DOOR SEAL POLAR WHITE (552X713) PLUG AL/SILVER X BUSHING H. F24 FREEZER Air NTC probe open / - Check NTC probe, ensuring that the impedance value read on pins 5 and 6 of wiring connector J11 is compatible with the values in the temperature-impedshort-circuit ance correlation table (also heat the probe by holding it with your hand where - Check efficiency of contacts on connector J11 on the PCB; possible and checking the change in the impedance value); - Renew main PCB. com) to access data and updates of electrical diagrams, technical bulletins and spare parts