duty 13 15 2,3 + 0,5 0,103 Besides positioning applications, tractive electromagnets may also be used in the following: Ticket stamping/punching machines, guiding, locking, triggering, metering, ventilating, pushing, clamping, riveting, blocking, etc. Dimensional drawing 43 M8 25 56 40 50,6 M4 56 6 5,3 25,5 105 Figure Connection and circuit diagram # ! Bosch Automotive Aftermarket ! ! 2007 | 2008 Relays | 79 Relays Power relays Series 009 Normally open relay 24 V 0 333 009 002 Technical data Nominal excitation current Nominal load current Nominal load current Service life of contact Service life of contact Interrupting current with inductive load Dimensions Weight A A A Thousand Thousand A mm kg Contin. Pull-in winding/hold-in winding 3) At nominal voltage and winding temperature 23 +5 °C. In the event of any modifications, please state the known product here. 5,01) V < 50 mV < 80 mV < 175 mV < 250 mV < 50 mV3) < 80 mV4) 24 V 16. 4) 14,5 2) Ag 1A 240 A / 70 A 70 A / 50 A 10 mV 4K > 1 x M cycles > 2 x N cycles I (u = 13,5 V) i on3) / off o at 23 °C / 85 °C 10 A contact current 10 A contact current 6,3 1) 9,5 At 23 °C coil temperature. 4,0 < 10 /< 15 single fixed 46 + 5 A Dimensional drawing 62 44 31,5 21 75 max. 4) at +20 °C 1) Dimensional drawing 12 1,7 4 Ø 5,4 10 6 22 28,5 86 11,5 26 28,5 87 87a 30 85 Blade terminal size: 6. of operations 3) When a socket housing is used and when installed with blade terminals pointing downwards. © 2006 Robert Bosch GmbH Automotive Aftermarket Postfach 41 09 60 76225 Karlsruhe Token fee: € 3. of operations 3) When a socket housing is used and when installed with blade terminals pointing downwards. Figure Connection diagram &$ &% &# ! ! &# 2007 | 2008 &% &$ Bosch Automotive Aftermarket 98 | Relay supplementary program Relays Mini relays F4 NO relays 0 986 332 071 BOSCH Part number Tyco Rover-Part number V23134-B0052-X127 YWB 10012 Technical data for contact side Contact material Minimum recommended current Max. duty < 55 < 350 5+1 1,18 Besides positioning applications, tractive electromagnets may also be used in the following: Ticket stamping/punching machines, guiding, locking, triggering, metering, ventilating, pushing, clamping, riveting, blocking, etc. Dimensional drawing M 110 8 58 66 30 2 17 40 8, 5 A Ø 30 55 50 56 31 Ø 48 V M4 5,3 SW 13 25 max. Duty Load current 1 s Mechanical Electrical LxWxH 24 1,3 230 1500 1250 100 375 135 x 70 x 128 1,3 Excitation and switching voltage. Dimensional drawing M4 H 28,5 Ø 28 Ø3 Ø 8,6 38 48 5,3 H 3 15,2 48,5 Lift Figure 2007 | 2008 Connection and circuit diagram Bosch Automotive Aftermarket 140 | Tractive electromagnets Tractive electromagnets Tractive electromagnets Pushing electromagnets 12 V 0 330 106 006 Technical data Nominal voltage Working stroke Nominal wattage1) Operating mode2) Forces Working stroke3) Forces With armature pulled in3) Weight V mm W N N kg 12 2,6 42,5 Short-time duty < 20 < 30 0,19 Besides positioning applications, tractive electromagnets may also be used in the following: Ticket stamping/punching machines, guiding, locking, triggering, metering, ventilating, pushing, clamping, riveting, blocking, etc. 48 38 48 2 Ø 28 Ø 10 Ø 16 2 H 5,3 28 H4 Lift Figure 2007 | 2008 Connection and circuit diagram Bosch Automotive Aftermarket 130 | Tractive electromagnets Tractive electromagnets Tractive electromagnets Pulling electromagnets 24 V 0 330 001 021 Technical data Nominal voltage Working stroke Nominal wattage1) Operating mode2) Forces Working stroke3) Forces With armature pulled in3) Forces Return spring Weight V mm W N N N kg 24 1,3 14 Contin. 8 mm to DIN 46 244 (similar to ISO 8092) Figure Connection and circuit diagram &$ &%= &% &# ! &% &$ &%= &# ! Recommended polarity Bosch Automotive Aftermarket Terminal 86 + Terminal 30 + 2007 | 2008 Relays | 29 Relays Mini relays Changeover relay 12 V 0 332 209 138 Technical data Resistive load1) - NO contact Resistive load1) - NC contact Motor load2) - NO contact Motor load2) - NC contact Lamp load1) - NO contact Lamp load1) - NC contact Contact material Overall resistance of excitation circuit4) Response time Release time Degree of protection Terminals3) Degree of protection Housing Illustration / Dimension drawing A/Thousand A/Thousand A/A/Thousand A/A/Thousand A/Thousand A/Thousand 50/>75 20/>100 90/40/>75 35/15/>50 30/>75 5/>300 40/>150 15/>150 75/30/>150 25/10/>150 20/>150 30/>300 10/>300 50/20/>300 15/5/>300 10/>300 silver tin oxide 75+5 < 10 < 10 IP 20 IP 5K4 2 A ms ms 1) Switching current/no. 8 mm to DIN 46 244 (similar to ISO 8092) Figure Connection and circuit diagram &$ &%= &% &# ! &% &$ &%= &# ! Recommended polarity Bosch Automotive Aftermarket Terminal 86 + Terminal 30 + 2007 | 2008 Relays | 35 Relays Mini relays Changeover relay 24 V 0 332 209 203 Technical data Resistive load1) - NO contact Resistive load1) - NC contact Motor load2) - NO contact Lamp load1) - NO contact Lamp load1) - NC contact Contact material Overall resistance of excitation circuit4) Response time Release time Degree of protection Terminals3) Degree of protection Housing Illustration / Dimension drawing A/Thousand A/Thousand A/A/Thousand A/Thousand A/Thousand 8/>50 A ms ms 20/>250 10/>250 40/16/>250 16/>250 5/>150 silver tin oxide 255+15 < 15 < 15 IP 20 IP 5K4 2 1) Switching current/no. Dimensional drawing 43 25 M8 88 40 60 50,6 15,7 11 30 56,2 Figure 3 5,3 9 30 114 Connection and circuit diagram # ! 2007 | 2008 ! ! Bosch Automotive Aftermarket 84 | Relay supplementary program Relays Micro relays A Characteristic quantities Rated voltage Test voltage Upper limit temperature Thermal resistance Ambient temperature Max