This popup allows the user to copy assignments between peak lists, which can be useful when analysing the differences between to spectra under slightly different conditions, and between molecular chains, which can be useful when duplicating a molecular chain in a homo dimer.
The {Between Peak Lists} tab provides the user interface for copying assignments between peak lists. Before copying assignments the user needs to specify the source and target peak lists, and various other options. Good matches between peaks in the source and target peak lists are shown in Source Peaks table. Selecting the matches allows the user to choose to which target peak the assignment is copied in the Target Peaks table using [Assign Selected Target]. Optionally, peaks can be inspected in the spectrum window that is used for following the copying of assignment, in which the peaks are marked.
Global copying of assignments can be done using the [Assign Singly Matched] and [Assign All to Closest] buttons.
The Assignment: Copy Assignments popup (Between Peak Lists).
Specifies the source peak list from which peak assignments are copied to the target peak list.
Specifies the target peak list to which peak assignments from the source peak list are copied.
If selected, this option causes peaks that were already copied to the target list to be shown in the Source Peaks table.
If selected, this option causes assignments in the target peak list to be overwritten by the assignment in the source peak list.
If selected, selected peak matches are marked and displayed in the spectrum window specified under [Follow window].
If selected, only good matches are displayed in the Source Peaks table. Peaks that have no matches with the specified tolerances are excluded from the displayed list.
If selected, also aliased peaks are considered as good matches.
Specifies the spectrum window in which peaks are marked and centered on selection of a match in the Source Peaks or Target Peaks tables.
Specifies the threshold or maximum of the distance that peaks are allowed to have in order to be considered a match. The distance is calculated using the scale factor for each dimension/nucleus:
Â
distance = sqrt(((x1-x2)/scale factor in x)^2 + ((y1-y2)/scale factor in y)^2)
Scale factor for calculating distances in the 1H dimension.
Scale factor for calculating distances in the 15N dimension.
Scale factor for calculating distances in the 13C dimension.
This table lists all the source peaks and information on potential matches of the target peaks to the source peaks.
The serial number of the source peak.
The assignment of the source peak.
The number of peak matches for the source peak found in the target peak list.
The closest distance in the matching peaks found in the target peak list.
The best match, i.e. the match with the closest distance to the source peak, found in the target peak list.
This table lists all the matching target peaks for a source peak selected in the Source Peaks table.
The target peak serial number.
The current assignment of the target peak.
The distance of the target peak to the source peak.
Copies the assignment from the source peak to the selected target peak.
Copies the assignments of all the source peaks that have only a single matching target peak (i.e. Num. Matches=1) to the matching target peak.
Copies the assignments of all the source peaks to the closest matching target peak.
The {Between Molecule Chains} tab provides the user interface for copying assignments between molecule chains. The user needs to specify the source and target molecular chains, and the experiments for which assignments are copied. Depending on the chosen options, assignments can be duplicated or moved.
The Assignment: Copy Assignments popup (Between Molecule Chains).
Specifies the source molecular chain from which assignments are copied to the target molecular chain.
Specifies the target molecular chain to which assignments are copied from the source molecular chain.
This table lists the experiments for which peak assignments are copied from the source to the target molecular chain.
The experiment serial number.
The experiment name.
The molecular chain from which assignments are copied.
The molecular chain to which assignments are transferred for the given experiment. There are 3 options:
If |Final Chain| equals |Current Chain| no action is taken.
If |Final Chain| is different from |Current Chain| the assignments are transferred, i.e. moved, from |Current Chain| to |Final Chain|.
If |Final Chain| is set to 'Both', the assignments are copied.
Sets the |Final Chain| of the selected experiment to the Source Chain.
Sets the |Final Chain| of the selected experiment to the Target Chain.
Sets the |Final Chain| of the selected experiment to 'Both'.
This table lists the residues in the source and target (destination) molecular chains. Residues can be selected and enabled or disabled for transfer of assignments.
The residue in the source molecular chain.
The number of resonances in the spin system of the source residue.
The residue in the destination molecular chain.
The number of resonances in the spin system of the destination residue.
Start copying the assignments between the molecular chains according to the specified options.
Enables the transfer of assignments for the selected residues.
Disables the transfer of assignments for the selected residues.