Calculate heteronuclear NOE values from peak intensities

It is possible in Analysis to calculate heteronuclear NOE values for amide resonances based upon a comparison of the peak intensities in spectra that derive from an NOE saturated experiment and an unsaturated (reference) experiment. This is done in the Data Analysis: Heteronuclear NOE popup, which is accessible from M: Data Analysis: Heteronuclear NOE:

The idea of this functionality is that three peak lists are chosen, two of which are for heteronuclear NOE experiments (H,N axes); unsaturated reference and saturated, and one which is the source of assignments and peak locations. This last “Assignment” peak list may be the same as one of the NOE peak lists, but may also be entirely separate. To calculate the heteronuclear values, do as follows:

If pairs of NOE saturated and reference peaks are found then the actual heteronuclear NOE value is displayed as the |Intensity Ratio| in the last, rightmost, column of the table:

To store these values as a NOE measurement list so that the data can be saved in the CCPN project without need for recalculation, the [Create Hetero NOE List] function can be used. The results are then available to view at any time in the Measurement Lists table (M: Data Analyses: Measurement Lists).

For more information about the Data Analysis: Heteronuclear NOE popup see the in-program documentation.