Backend Integration Guide
Schneider Electric Stations can be integrated into the eCarUp billing system in just a few steps. Once installed in your account, you can easily define the conditions of use for your stations yourself (prices, users, available times, etc.). You decide who can charge, when and at what price.
- Prerequisite for integration via OCPP
- Configuration in the web portal for station operators
- Learn more about our premium functions here
Preparatory steps for the integration of OCPP stations into the eCarUp Cloud
Your charging station is installed and your computer is in the same network as the charging station
You have created an account in the eCarUp app
Log into the eCarUp web portal with your account data and click on the "OCPP" tab in the menu on the left under Stations
Copy the URL to the clipboard and store it at the desired station in the web interface.
EVlink Pro AC
Integration of the EVlink AC Pro
To access the station via smartphone, the following steps are necessary:
Install the "eSetup" app from Schneider Electric on your cell phone;
Open a user account there.
Step 1
Select EVlink Pro AC
Step 2
Search run is started
Step 3
Select charging station
Step 4
Enter PIN code (this was assigned during registration)
Step 5
Select configuration
Step 6
Select supervision for OCPP setting
Step 7
Supervision ON
Insert OCPP URL normally from your account
Example: ws://www.ecarup.com/api/Ocpp16/xxxxxxxxxxxxxx
Select Authentication Required (Public)
Step 8
Make network settings
Step 9 (optional)
Define offline mode
Step 10
Save settings and restart the station.
EVlink Pro DC
Would you like to integrate the DC charging station from Schneider with eCarUp ?
Send your OCPP URL to the following e-mail from Schneider: services@ch.schneider-electric.com
Schneider Electric will get back to you as soon as possible.
EVlink Smart Wallbox
Integration of the EVlink Smart Wallbox
Connect to the station with Ethernet
The following IP address is statically assigned on your PC: 192.168.0.x (x is an integer between 241 and 249)
Subnet mask: 255.255.255.0 + no standard gateway, no DNS and no proxy
Open your web browser and enter http://192.168.0.102 in the URL address bar.
Username (admin), password (ADMIN)
Web Interface
General Settings
Removed all spaces from the charging station name
Set station type on Supervised
Chose under "Authentication done by": Supervision
Supervision
Set OCPP version to 1.6
Complete the supervision URL. You get the URL from your eCarUp account (preparatory steps)
Rename the charging station ID without spaces
Restart the station
EVlink load management system
Connect to the LMS with Ethernet ETH1
The following IP address is statically assigned on your PC: 192.168.0.x (x is an integer between 241 and 249)
Subnet mask: 255.255.255.0 + no standard gateway, no DNS and no proxy
Open your web browser and enter http://192.168.0.128 in the URL address bar.
Username (admin), password (ADMIN)
Remote supervision
Enable to "ON"
Remote supervision URL address: completely insert the eCarUp URL from the account.
Advanced Configuration
Admin --> Advanced --> Advanced configuration --> Enable plug numbering --> ON
Charging Stations
A zone must be created in which the station can be added.
It is essential to give the Identity box a new name.
Final Inspection
The station should now receive the monitoring URL from the LMS
The ID of the charging station should be identical
Advanced setting via maintenance tool (eCarUp Premium)
The upload interval of the Meter Values may vary from station to station.
We recommend an interval between 30-60s. This is the only way we can better calculate and display the current charging power on the app.
You can change this as follows:
Get Configuration (to read out what is programmed).
Change Configuration (to overwrite the value)