The Box Proxy for the integration of older Green Motions stations is now available. This means that the charging stations can already be connected to the eCarUp platform and tested using the instructions below. However, enhancements and/or improvements may still be made.
The following charging station models are currently supported by the Box Proxy:
Eaton Stations can be integrated into the eCarUp billing system in just a few steps. Once installed in your account, you can easily define the conditions of use for your stations yourself (prices, users, available times, etc.). You decide who can charge, when and at what price.
Prerequisite for integration via OCPP
Configuration in the web portal for station operators
Learn more about our premium functions here
Make sure that your charging stations are installed and that your computer or cell phone is connected to the same network as the charging station.
Open the eCarUp web portal and log in with your account details.
Click on the "Stations" tab in the menu on the left-hand side.
Select the "OCPP" tab.
Copy the URL to the clipboard.
Go to the web interface of the desired station and paste the copied URL accordingly.
Tested firmware version: 2003
Info: The configuration page is active for 30 minutes, after which the station must be restarted.
Switch on the station using the circuit breaker
Connect to the PC via Ethernet to one of the three LAN ports on the Teltronika router in the station
Go to the following IP in the browser: 192.168.52.11
Click on Open page and enter the login data supplied in the browser. Default is admin / admin.
Check software status, Bienne 2003 is the tested firmware.
Select OCPP Server
Set Backend to Custom
Add eCarUp URL from your account
Example:
wss://www.ecarup.com/api/Ocpp16/D037091EE3xxxxxx/
Set Security Profile to None
Save
Restart station
tested Firmware v.1807
Info: The configuration page is active for 30 minutes, after which the station must be restarted.
Switch on the station
Activate the WLAN on your PC or cell phone
The station makes a hotspot with the last 4 digits of the serial number. E.g. GM_Mxxxxx
Password is supplied (GreenMotion!1052)
Connect your PC or cell phone to the hotspot and go to the following IP in the browser: 192.168.53.1
Configure the network and continue with the steps below.
You may receive a warning message before accessing the configuration page. Click on continue.
Select OCPP Server
Set Backend to Custom
Add eCarUp URL from your account
Example:
wss://www.ecarup.com/api/Ocpp16/D037091EE3026BE0/
Set Security Profile to None
Save
Restart station
The upload interval of the Meter Values may vary from station to station.
We recommend an interval between 30-60s. This is the only way we can better calculate and display the current charging power on the app.
You can change this as follows:
Get Configuration (to read out what is programmed).
Change Configuration (to overwrite the value)
If the station does not appear on our system and Eaton Support cannot find a solution to the problem, please provide us with the log files for review.
Maintenance --> System Log --> Get the Logs from the last 2 Hours.