Dual PRI (2P) Gateway Setup
Dual PRI (2P) Gateway best practice setup with a single hardware device with two PRI ports: In which P1 (PRI port 1) will be connected to the Telco device and P2 (PRI port 2) will be connected to the Legacy PBX.
- Log into Comma GUI. (How to log into the Comma GUI of your Wanderbox or Com.X )
- Select Start
- Select Configuration
- Select Hardware
- The Comma ITA 2P device (int1) will be listed under devices.
- Right Click on the Comma ITA
- Select Edit
- Set the Timing Mode as PRI Priority 1
- Select Accept
- Under Ports on the left hand side, Right click on P1
- Select Edit
- Set the Signalling Role to Terminal. (This port P1 will be connected to the telco device)
- Select Accept
- Under Ports on the left hand side, Right click on P2
- Select Edit
- Set the Signalling Role to Network. (This port P2 will be connected to the Legacy PBX)
- Enable transmit clocking. (Com.X will then transmit the clocking to Legacy PBX, it receives from the telco device)
- Select Accept
- Select Review Apply