In the event you discover a small fire (waste-basket size), notify people in the area and send someone to notify the Operations Manager. If comfortable, use a fire extinguisher to extinguish the fire. Fire extinguishers are located at red support beams throughout the building as listed on the Facility map.
The Operations Manager will obtain the following information about the fire:
Location
Size
Are there any injuries?
If larger than a waste basket, the Operations Manager/Front Office Reception will call “911” to notify the Fire Department.
In the event of a fire the Operations Manager will contact everyone to evacuate the building.
Use the closest, but safest exits to evacuate the building. Facility maps are posted throughout the building. Note: Employees should know the two closest exit routes from their work station.
Employees need to assist in ensuring everyone in their area is notified to evacuate, including contractors and visitors. EVERY EMPLOYEE, CONTRACTOR AND VISITOR MUST LEAVE THE BUILDING IMMEDIATELY UPON NOTICE TO EVACUATE.
The Operations Manager on site will attempt to inspect all areas of the building to ensure everyone has evacuated but will in no way endanger themselves.
Employees must report to the assigned safety zone located across West Corporate Dr in the parking lot of 1185 West Corporate Dr directly across the street from the SkyVine ITAD facility. In the event that the assigned safety zone becomes unsafe, the Operations Manager will direct employees to an alternate area.
After personnel are accounted for, an announcement will be made whether to allow reentry into the building or instruct personnel to go home and wait to be notified when the building will be reopened.
In the event you discover a spill, notify the people in the area and send someone to notify the Operations Manager or employee trained in spill response procedures.
Remember the 3 C's of handling any accidental spills. Control Contain and Clean up.
The Operations Manager or trained employee determine the specific substance of the spill by following the procedures listed below:
If the spill came from a SkyVine ITAD in-house material, go to the Safety Data Sheets for the proper clean up method.
If the spill came from a customer’s material, call the customer and ask what the material is and get the proper clean up method.
If the material is flammable (e.g. gasoline, or a solvent), make sure you extinguish all ignition sources immediately.
If the spill involves broken CRT glass, follow the Broken CRT Cleanup Procedure listed below.
If the spill involves broken fluorescent tubes, follow the Broken Fluorescent Tube Cleanup Procedure listed below.
If the spill involves oil, follow the Used Oil Cleanup Procedure listed below.
Based on the type of spill, clean up appropriately with the items provided in the spill kit bucket located in the Reusable Tech Room.
Wear the following personal protective equipment, provided in the spill kit:
Eye protection
gloves
If splash potential exists, supplement with protective apron & full-face shield
All spill and spill cleanup supplies are disposed of properly based on the type of spill.
After cleanup of the spill has been completed, notify the Operations Manager who will complete a spill incident report.
The Operations Manager will ensure the spill kit has been restocked after use.