The menu to adjust the self-priming/suction settings is blocked. Is there a password for this?
No. This part of the menu is only available with the KIWA / DIN versions of the Easybox.
In that case there is no password needed.
Can I connect the Easybox to my main water lines in The Netherlands?
Yes, but you will need the KIWA version for this to comply with all laws and regulations.
What is the minimum length of a drip hose in combination with an Easybox?
Tests have been done with an easybox mini 3 and a drip hose to see what the minimum length should be to achieve 2 L/m in order to keep an E.sybox (mini) running.
The result is that the length of the drip hose should be at least 35 meters.
Below the detailed data:
Length of hose. Pressure (SP of the pump). Number of liters per minute.
100M 1 bar 8.1
2 bar 11.5
3 bar 13.2
4 bar 13.2
80M 1 bar 7.7
2 bar 10
3 bar 10
4 bar 10
60M 1 bar 6.6
2 bar 7
3 bar 7
4 bar 7
40M 1 bar 4.5
2 bar 4.5
3 bar 4.5
4 bar 4.5
35 M all pressure 3.0
30 M all pressure lower then 2
Can I connect the Easybox to my main water lines in France?
Yes, there are no laws and regulations for this in France.
Can I connect the Easybox to my main water lines in Germany?
Yes, but you will need the DIN1988-500 version for this to comply with all laws and regulations.
Can I disconnect the power supply whenever I do not need the Easybox?
Even though this is possible, we would strongly recommend not to. It's best to always leave the Easybox connected. The PCB (printed circuit board) could be damaged when the pump is activated and deactivated regularly like this.