Visit Official SkillCertPro Website :-
For a full set of 300+ questions. Go to
https://skillcertpro.com/product/certified-labview-associate-developer-clad/
SkillCertPro offers detailed explanations to each question which helps to understand the concepts better.
It is recommended to score above 85% in SkillCertPro exams before attempting a real exam.
SkillCertPro updates exam questions every 2 weeks.
You will get life time access and life time free updates
SkillCertPro assures 100% pass guarantee in first attempt.
Question 1:
A button is pressed once and immediately turns on the light of a dark room. The light stays on after the button is released. What is the mechanical action of the button?
A. Switch when released
B. Switched until released
C. Switch when pressed
D. Latch until released
E. Latch when released
F. Latch when pressed
Answer: C
Explanation:
The light stays on after the button is released, so this is not a latching action or switched until released, which would only turn the light on while the button is being pressed. Since the keyword given in the question was “immediately“ so the correct option should be “switch when pressed“.
Question 2:
You have a front panel control on a top-level VI that you must manipulate from within a SubVI.
Which of the following could you pass to the SubVI to accomplish this?
A. The control‘s methods
B. The control‘s reference
C. The control‘s data type
D. The control‘s properties
Answer: B
Explanation:
The only answer option that can be passed from calling VI to subVI is the control reference. The reference can then be used with Property Nodes and Invoke Nodes to call properties and methods, respectively. The data type is a property of the control.
Question 3:
Which combination of words correctly completes the following statement? Unlike _____ Property Nodes, _____ Property Nodes require _____ as inputs in order to function correctly.
A. Implicit; Explicit; Control References
B. Explicit; Implicit; Data Value References
C. Explicit; Implicit; Control References
D. Implicit; Explicit; Data Value References
Answer: A
Explanation:
Implicit Property Nodes are explicitly linked to their owning control or indicator. No reference wires are needed. Explicit Property Nodes require a reference wire to determine which control the Property Node is manipulating. Data Value References have nothing to do with Property Nodes.
Question 4:
Which chart update mode should be used to compare old and new data separated by a vertical line? This chart will display similar to an electro-cardiogram (EKG).
A. Sweep Chart
B. Step Chart
C. Strip Chart
D. Scope Chart
Answer: A
Explanation:
Strip charts start plotting from left to right and continue to scroll while plotting. Scope charts start plotting from left to right and continue until the chart is full. Then the chart is cleared, and plotting resumes at the left. Sweep charts behave similarly to scope charts, except that once the chart is full, sweep charts start plotting at the left and progressively overwrite previously plotted data. There is no such thing as a Step chart in LabVIEW.
For a full set of 300+ questions. Go to
https://skillcertpro.com/product/certified-labview-associate-developer-clad/
SkillCertPro offers detailed explanations to each question which helps to understand the concepts better.
It is recommended to score above 85% in SkillCertPro exams before attempting a real exam.
SkillCertPro updates exam questions every 2 weeks.
You will get life time access and life time free updates
SkillCertPro assures 100% pass guarantee in first attempt.
Question 5:
You have a front panel control on a top-level VI that you must manipulate from within a SubVI.
Which of the following could you pass to the SubVI to accomplish this?
A. The control‘s methods
B. The control‘s reference
C. The control‘s data type
D. The control‘s properties
Answer: B
Explanation:
https://docs.microsoft.com/en-us/MicrosoftTeams/quality-of-experience-review-guide
Question 6:
Which of the following methods will create an XY Graph with two plots?
A. Bundle the X and Y array pairs together into two clusters and then create an array of these two clusters.
B. Create a single cluster from two arrays of X values and two arrays of Y values in an X,Y, X,Y pattern.
C. Create a single array of each of the X arrays and Y arrays in an X,Y,X,Y pattern.
D. Bundle the X and Y array pairs together into two clusters and create a cluster of these two clusters.
Answer: A
Explanation:
XY graphs accept a cluster of two arrays, an X array and a Y array to generate a single plot. To generate multiple plots, XY graphs accept an array of these clusters.
Question 7:
In what instance would you use the Probe tool rather than Highlight Execution?
A. To look into a SubVI, as the process is running
B. To see the value of a wire in real-time
C. To see the flow of data
D. To slowdown the VI and show data values in wires
Answer: B
Explanation:
The Probe tool allows the developer to see data in a wire during execution, but it does not slow down execution at all. Highlight Execution slows down execution and displays the flow of data, and the Single Stepping tools allow the developer to look into subVIs.
For a full set of 300+ questions. Go to
https://skillcertpro.com/product/certified-labview-associate-developer-clad/
SkillCertPro offers detailed explanations to each question which helps to understand the concepts better.
It is recommended to score above 85% in SkillCertPro exams before attempting a real exam.
SkillCertPro updates exam questions every 2 weeks.
You will get life time access and life time free updates
SkillCertPro assures 100% pass guarantee in first attempt.