Long side of building will be numbered
Short side of building will be lettered
The bottom left most portion of the structure is the origin for all designations. Bottom to top, left to right.
Intermediate grids (X.#) are reserved for secondary structural elements. The (#) intermediate numeric is based upon relative location to nearest integer (or letter).
All Letters are to be upper case
Letters not to be used are
The letter “O”
The letter “I”
A Coordination view for Grid lines is required. Only Grid lines & the elements they define are to be visible in this view + Dimensions.
Confirm grid line Dimension by setting Project Units -> Length -> Format -> Units to Decimal inches with Rounding set to Custom and Rounding increment 0.000000000001. This will show any small errors.
Adjust all grid line dimensions from origin in both X & Y directions, pushing tolerance errors away from origin.
Dimensions should target to be design to the nearest inch without adjusting design intent.
Pin all Grid Lines upon confirming all dimensions
Create a Design Option > Option Set. Rename the Option Set to “Grid Line Lock”. Add all grid lines to this option after confirmation of dimensions with high precision.