System Family: Railing
Type: F.Railing.Egress Path
'Rail Structure (Non-Continuous)' - F.Profile.Egress Path
Utilizes a 'Height' of 1/32" within 'Edit Rails' to align seamlessly with the circle and arrow balusters. This adjustment is necessitated by the construction of the profile family being below the horizontal reference plane
Baluster Start Post - F.Baluster.Post.Egress Start Circle - Top - Rail 1
Baluster Corner Post - None - Top - Rail 1
Baluster End Post - F.Baluster.Post.Egress End Arrow - Top - Rail 1
Note: Instead of using a 'Top Rail', 'Rail Structure (Non-Continuous)' is used for consistency with F.Railing.Accessible Route
Keynote: Built-in parameter - The below Keynotes correspond to the types.
xxxx.xx (waiting on Jeff)
Forum uses 'Railings 'because of their built in 'Length' parameter that is the total distance. This method avoids adding up multiple line segments, increasing efficiency
Future test case: Use 'Pipe' instead of 'Railing'
Future test case: Use 'Path of Travel' instead of 'Railing'
Family Name: F.Profile.Egress Path
Category: Profiles
1/32" x 1/32" square profile
Drawn at small scale to appear as a simple line in plan view
Positioned under the horizontal reference plane to align with circle and end arrow (utilizes a 'Height' of 1/32" within 'Edit Rails' to avoid 'Top reference is below Bottom reference' error)
F.Default
F.URL = Type,URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Family Name: F.Baluster.Post.Egress Start Circle
Category: Baluster-Post
Extruded to 1/32" to align with F.Profile.Egress Path
F.Default
Post = System Parameter - Type,Yes/No - Checked on
F.URL = Type,URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Family Name: F.Baluster.Post.Egress End Arrow
Category: Baluster-Post
Extruded to 1/32" to align with F.Profile.Egress Path
F.Default
Post = System Parameter - Type,Yes/No - Checked on
F.URL = Type,URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Family Name: System Family: Railing
Type: F.Railing.Accessible Route
A5.61 - Unit Plans & Interior Elevations on the Accessible Route Plan
Enlarged Floor Plans of Residental and or Clubhouses, based on accessible code requirements
FBC 402 Accessible Routes
'Rail Structure (Non-Continuous)' - F.Profile.Accessible Route
Baluster Start Post - None - Top - Rail 1
Baluster Corner Post - None - Top - Rail 1
Baluster End Post - None - Top - Rail 1
Keynote: Built-in parameter - The below Keynotes correspond to the types.
xxxx.xx (waiting on Jeff)
This is used as an alternative to a filled region. You position the centerline and adjust it into the desired location.
Family Name: F.Profile.Accessible Route
Category: Profiles
Uses F.Clearance Zone 'Material'
F.Default
F.Height = Type,Length,Dimensions - Set to 6' 8" per FBC 402 Accessible Routes
F.Width = Type,Length,Dimensions - Set to 3' 0" per FBC 402 Accessible Routes
F.URL = Type,URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Family Name: F.GMOD.Clear Floor Space.Rectangle
Category: Generic Models
A5.61 - Unit Plans & Interior Elevations on the Accessible Route Plan
Enlarged Floor Plans of Residential and or Clubhouses, based on accessible code requirements
F.2' 6".4' 0".Default.Appliances.PlumbingFixtures (30"x48")
FBC 305.3 Size Min. size. Often used with Appliances and Plumbing fixtures.
F.2' 6".5' 0".AlcoveObstructed3Sides (30"x60")
FBC 305.7 Maneuvering Clearance
Clear floor spaces are typically 30″ x 48″ minimum unless blocked on all or part of three sides for more than half the distance. If blocked by objects or within an alcove, then the clear floor space increases from 30″ x 48″ to either 36″ x 48″ or 60″ x 30″.
F.4' 0".4' 8".FHA.Toilet (48"x56")
Part Two: Chapter 7,Fair Housing Act Design Manual, Part B: Usable Bathrooms, Clear Floor Space at Toilets, 7.43
F.4' 0".5' 0".ParallelApproachHalfBlocked (48"x60")
FBC 305.7 Maneuvering Clearance
For parallel approach, if it is the 30″ side which is blocked for more than half, then the length increases from 48″ to 60″. If the clear floor space is even partially blocked on a side, one full edge of the clear floor space is required to adjoin an accessible route or another clear floor space.
F.4' 0".5' 6".FHA.Toilet.WallMounted (48"x66")
Visual Guide to the Accessibility Checklists Part I: Uniform Federal Accessibility Standard (UFAS), 4.16.2 CLEAR FLOOR SPACE. , Figure 28 Clear Floor Space at Water Closets
Part Two: Chapter 2, Fair Housing Act Design Manual, Page 7.43
Part Two: Chapter 7, Fair Housing Act Design Manual, Part B: Usable Bathrooms, Clear Floor Space at Toilets, Page 7.43
F.4' 8".5' 0".ADA.Toilet.WallMounted (56"x60")
FBC 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment
F.4' 11".5' 0".ADA.Toilet.FloorMounted (59"x60")
FBC 604.8.1.1 Size of Wheelchair Accessible Toilet Compartment
F.5' 0".5' 6"ADA.UFAS.Toilet.WallMounted (60"x66")
FBC 604.3.2 (Exception) Overlap of Water Closet Clearance in Residential Dwelling with Lavatory
Only found on 1/4" = 1'-0" sheet scales. Any other sheet scale may cause text scale issues
F.Clearance Zone 'Material' is used for 3D Extrusion
'Object Style'- 'Subcategory' -F.Accessibility.Rectangle.Clearance Zone
Instead of having the dashed linework separate from the 3D extrusion, the 3D extrusion takes on the dashed linework 'Object Style' ('Subcategory' - F.Accessibility.Rectangle.Clearance Zone)
Regular text in the family is not visible in the project, so we use a separate family named F.Text.Clearance Zone which is embedded into this family
F.2' 6".4' 0".Default.Appliances.PlumbingFixtures (30"x48")
F.2' 6".5' 0".AlcoveObstructed3Sides (30"x60")
F.4' 0".4' 8".FHA.Toilet (48"x56")
F.4' 0".5' 0".ParallelApproachHalfBlocked (48"x60")
F.4' 0".5' 6".FHA.UFAS.Toilet.WallMounted (48"x66")
F.4' 8".5' 0".ADA.Toilet.WallMounted (56"x60")
F.4' 11".5' 0".ADA.Toilet.FloorMounted (59"x60")
F.5' 0".5' 6"ADA.UFAS.Toilet.WallMounted (60"x66")
Default Elevation = Built-in parameter - Should be set to the level of the finished floor
F.Length = Type, Length
F.Length.Inches = Type, Number - This Parameter is built to convert F.Length from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Length / 1') * 12)
F.Width = Type, Length
F.Width.Inches = Type, Number - This Parameter is built to convert F.Width from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Width / 1') * 12)
F.Visibility = Instance,Yes/No,Visibility - Controls visibility of the 3D extrusion for cases where the user wants to turn off visibility of the family individually (one by one). If using 'Visibility Graphics' to tun off family in the view, you must also uncheck F.Number.Visibility for the numbers to go away. The family is outlined with invisible lines that highlight blue when hovered over. This is to help the user find the family if F.Visibility is unchecked.
F.Number.Visibility = Instance, Yes/No, Visibility - Controls visibility of the numbers only due to a change requested by Forum to show the clear floor space without the numbers. We have provided this parameter incase the decision changes.
URL = Type, URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Keynote: Built-in parameter - The below Keynotes correspond to the types.
0100.01 Type: F.2' 6".4' 0".Default.Appliances.PlumbingFixtures
0100.02 Type: F.2' 10".4' 0", removed for unknown use
0100.03 Type: F.2' 6".5' 0".AlcoveObstructed3Sides
0100.04 Type: F.4' 0".4' 8".FHA.Toilet
0100.05 Type: F.4' 0".5' 0".ParallelApproachHalfBlocked
0100.06 Type: F.4' 0".5' 6".FHA.UFAS.Toilet.WallMounted
0100.07 Type: F.4' 8".5' 0".ADA.Toilet.WallMounted
0100.08 Type: F.4' 6".5' 0", removed for unknown use
0100.09 Type: F.4' 11".5' 0".ADA.Toilet.FloorMounted
0100.10 Type: F.5' 0".5' 6"ADA.UFAS.Toilet.WallMounted
Used for side approach and front approach where no roll under clearance is required.
Need to revisit to solve for a solution to 'Text Label' F.Text.Clearance Zone not being able to link to 'Subcategory'
Clearance Materials - Click for more information
Family Name: F.GMOD.ClearFloorSpace.Rectangle.FrontApproach.KneeToeClearance
Category: Generic Models
The Rectangle Clear Floor Space With Knee/Toe Clearance has the same parameters and keynotes as F.GMOD.Clear Floor Space.Rectangle.
For clearance zones with knee/toe profiles, the geometry is split into two separate extrusions to achieve proper graphic display. This is done so the clear floor space can appear cleanly in plan without being obscured by the knee/toe clearance solid. The bottom extrusion represents the clear floor space and is extruded up to 9", which marks the beginning of the knee/toe profile. This portion is visible in plan using 'Visibility/Graphics Overrides' in the family. The top extrusion represents the knee/toe profile and includes the required 80" vertical clearance. This portion is turned off in plan using 'Visibility/Graphics Overrides' in the family. This method ensures the clear floor space displays cleanly in plan views, while the full clearance zone with the knee/toe profile appears correctly in elevations, sections, and 3D views.
Family Name: F.GMOD.ClearFloorSpace.Circle
Category: Generic Models
A5.61 - Unit Plans & Interior Elevations on the Accessible Route Plan
Enlarged Floor Plans of Residental and or Clubhouses, based on accessible code requirements
Anecdotally, the circular turn is preferred over the more restrictive T-Turn where possible.
Clearance Circle is only found on 1/4" = 1'-0" sheet scales. Any other sheet scale may cause text scale issues
F.Clearance Zone 'Material' is used for 3D Extrusion
'Object Style'- 'Subcategory' -F.Accessibility.Circle.Clearance Zone
Instead of having the dashed linework separate from the 3D extrusion, the 3D extrusion takes on the dashed linework 'Object Style' ('Subcategory' - F.Accessibility.T-Turn.Clearance Zone)
Regular text in the family is not visible in the project, so we use a separate family named F.Text.Clearance Zone which is embedded into the F.Generic Models.Clear Floor Space.T-Turn.Non Parametric family
Default Elevation = Built-in parameter - Should be set to the level of the finished floor
F.Diameter.Length= Type, Length - Dimension
F.Diameter.Number = Type, Number - This Parameter is built to convert F.Diameter.Length from (Length Unit format) to (Number Unit format) format to work with the associated embedded family F.GANN.Number.Clear Floor Space. There is no math being done but an equation is required to change the format units.
Formula: round((F.Diameter.Length / 12") * 12)
F.Visibility = Instance,Yes/No,Visibility - Controls visibility of the 3D extrusion for cases where the user wants to turn off visibility of the family individually (one by one). If using 'Visibility Graphics' to tun off family in the view, you must also uncheck F.Number.Visibility for the numbers to go away. The family is outlined with invisible lines that highlight blue when hovered over. This is to help the user find the family if F.Visibility is unchecked.
F.Number.Visibility = Instance, Yes/No, Visibility - Controls visibility of the numbers only due to a change requested by Forum to show the clear floor space without the numbers. We have provided this parameter incase the decision changes.
URL = Type, URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Keynote: Built-in parameter - The below Keynotes correspond to the types.
0100.11
Knee/Toe Clearance built in to revolve profile.
For clearance zones with knee/toe profiles, the geometry is split into two separate extrusions to achieve proper graphic display. This is done so the clear floor space can appear cleanly in plan without being obscured by the knee/toe clearance solid. The bottom extrusion represents the clear floor space and is extruded up to 9", which marks the beginning of the knee/toe profile. This portion is visible in plan using 'Visibility/Graphics Overrides' in the family. The top extrusion represents the knee/toe profile and includes the required 80" vertical clearance. This portion is turned off in plan using 'Visibility/Graphics Overrides' in the family. This method ensures the clear floor space displays cleanly in plan views, while the full clearance zone with the knee/toe profile appears correctly in elevations, sections, and 3D views.
Need to revisit to solve for a solution to 'Text Label' F.Text.Clearance Zone not being able to link to 'Subcategory'
Clearance Materials - Click for more information
Family Name: F.GMOD.ClearFloorSpace.T.Turn
Category: Generic Models
A5.61 - Unit Plans & Interior Elevations on the Accessible Route Plan
Enlarged Floor Plans of Residental and or Clubhouses, based on accessible code requirements
Anecdotally, an accessible T-Turn is often used instead of a circular turn in space-constrained environments like small bathrooms/stalls or closets, where a full circular turning radius is not feasible and often the last choice when ensuring the minimum code requirements are met.
T-Turn is only found on 1/4" = 1'-0" sheet scales. Any other sheet scale may cause text scale issues
F.Clearance Zone 'Material' is used for 3D Extrusion
'Object Style'- 'Subcategory' -F.Accessibility.T-Turn.Clearance Zone
Instead of having the dashed linework separate from the 3D extrusion, the 3D extrusion takes on the dashed linework (Dash 1/8") 'Object Style' ('Subcategory' - F.Accessibility.T-Turn.Clearance Zone)
Regular text in the family is not visible in the project, so we use a separate family named F.Text.Clearance Zone which is embedded into the F.Generic Models.Clear Floor Space.T-Turn.Non Parametric family
Default Elevation = Built-in parameter - Should be set to the level of the finished floor
F.Length.1.Length= Type, Length - Dimension
F.Length.1.Number = Type, Number - This Parameter is built to convert F.Length.1.Length from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Length.1.Length / 12") * 12)
F.Length.2.Length= Type, Length - Dimension
F.Length.2.Number = Type, Number - This Parameter is built to convert F.Length.2.Length from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Length.2.Length / 12") * 12)
F.Width.1.Length= Type, Length - Dimension
F.Width.1.Number = Type, Number - This Parameter is built to convert F.Width.1.Length from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Width.1.Length / 12") * 12)
F.Width.2.Length= Type, Length - Dimension
F.Width.2.Number = Type, Number - This Parameter is built to convert F.Width.2.Length from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Width.2.Length / 12") * 12)
F.Width.3.Length= Type, Length - Dimension
F.Width.3.Number = Type, Number - This Parameter is built to convert F.Width.3.Length from feet and fractional inches to inches for display in the associated embedded family F.GANN.Number.Clear Floor Space
Formula: round((F.Width.3.Length / 12") * 12)
F.Visibility = Instance,Yes/No,Visibility - Controls visibility of the 3D extrusion for cases where the user wants to turn off visibility of the family individually (one by one). If using 'Visibility Graphics' to tun off family in the view, you must also uncheck F.Number.Visibility for the numbers to go away. The family is outlined with invisible lines that highlight blue when hovered over. This is to help the user find the family if F.Visibility is unchecked.
F.Number.Visibility = Instance, Yes/No, Visibility - Controls visibility of the numbers only due to a change requested by Forum to show the clear floor space without the numbers. We have provided this parameter incase the decision changes.
F.Side1 = Instance, Yes/No, Visibility - Controls the visibility of the Side 1 profile.
F.Side2 = Instance, Yes/No, Visibility - Controls the visibility of the Side 2 profile.
F.Side1.Visibility = Instance, Yes/No, Visibility - Controls the visibility of the Side 1 profile and is linked to the Side1 geometry. Its pupose is to have F.Visibility be able to turn off everything at once while maintaining control over Side 1 and 2 when F.Visibility is on.
Formula: and(F.Visibility, F.Side1)
F.Side2.Visibility = Instance, Yes/No, Visibility - Controls the visibility of the Side 2 profile and is linked to the Side2 geometry. Its pupose is to have F.Visibility be able to turn off everything at once while maintaining control over Side 1 and 2 when F.Visibility is on.
Formula: and(F.Visibility, F.Side2)
F.URL = Type,URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
Keynote: Built-in parameter - The below Keynotes correspond to the types.
0100.12
Knee/Toe Clearance built in to extrusion profile.
For clearance zones with knee/toe profiles, the geometry is split into two separate extrusions to achieve proper graphic display. This is done so the clear floor space can appear cleanly in plan without being obscured by the knee/toe clearance solid. The bottom extrusion represents the clear floor space and is extruded up to 9", which marks the beginning of the knee/toe profile. This portion is visible in plan using 'Visibility/Graphics Overrides' in the family. The top extrusion represents the knee/toe profile and includes the required 80" vertical clearance. This portion is turned off in plan using 'Visibility/Graphics Overrides' in the family. This method ensures the clear floor space displays cleanly in plan views, while the full clearance zone with the knee/toe profile appears correctly in elevations, sections, and 3D views.
Need to revisit to solve for a solution to 'Text Label' F.Text.Clearance Zone not being able to link to 'Subcategory'
Dimensions were removed from one side to be consistent with the other symbology
Clearance Materials - Click for more information
Family Name: F.GANN.Number.Clear Floor Space
Category: Generic Annotations
F.Default
This family is embedded into
F.Generic Models.Clear Floor Space.Circle
F.Generic Models.Clear Floor Space.T-Turn
F.Generic Models.Clear Floor Space.Rectangle
F.Number = Instance,Number - Linked to 'Tag Label'
F.URL = Type,URL - Default preset and is used in combination with the Lookup tool on the Forum Ribbon to link to this page and section
May be deleted once 'Text Label' F.Text.Clearance Zone not being able to link to 'Subcategory' issue is solved