Unit Plan Examples
Sheet Layout Guidance
Note Plan
Accessibility Plan
Reflected Ceiling Plan
Dimension Plan
Exterior wall to be Plan North/ Top
With 2 Exterior Walls present, The exterior wall with a balcony to be Plan North/ Top
Walls shorter than 6 feet are not cut, even if they intersect the cut plane.
The 6 feet are measured from the top of the bounding box to the bottom of the primary view range. When the top of the wall is less than 6 feet, the entire wall shows as projection (no layers/ cut pattern) even where it intersects the cut plane. This behavior always occurs when the Top Constraint property for the wall is specified as "Unconnected".
The way that this can be worked around is to set the Top Constraint of the wall to be the same as the Base Constraint, but then provide a value in the Top Offset parameter. This will trick Revit into displaying the wall as cut (showing layers/ cut pattern).
UFAS
On required units the Fire Extinguisher may be provided under the sink with the Sysbol displayed atop the center of the sink.
Island coutertop overhang to be 2"
Closet to have a width dimension 5' min
Fold up grab bars behind the toilet in the bathroom in units, in the accessibility plan?
ID Type A and Type B Bathroom in the accessibility plan. If Type B, remove clear floor spaces on plans.
Only show outlets in special cases.
Range not to be flush with the counter.
Electrical outlets, where can accessible outlets be installed on the kitchen countertop? PL to comment on this 2.15.23
6' cut plane
Dimension all light locations except centered elements
...
The F.SPEQ.Portable FE Symbol.Non Parametric family will be used on the Unit Plans (A5.61). In scenarios where a fire extinguisher is provided under the sink, the Portable Fire Extinguisher SPEQ Symbol will be displayed atop the center of the sink. In scenarios where a fire extinguisher is provided on a wall with a bracket (in ADA roll under sink scenarios), the Portable Fire Extinguisher SPEQ Symbol will be placed along the wall.
The actual 3D fire extinguisher geometry is included in this family but is turned off in plan views, ensuring that only the symbolic representation is visible on drawings. The Amerex Purple K 796 extinguisher is used in this family, consistent with the F.SPEQ.Fire Extinguisher.Cabinet.Wall family, to account for the largest possible clearance requirements, ensuring code compliance even in worst-case scenarios.
F.SPEQ.Portable FE Symbol.Non Parametric
F.Tag.Door.Unit
Unit Door Tag - Click for more information
F.Tag.Room
Room Tags - Click for more information
F.Tag.Room.Non Parametric
Room Tags - Click for more information
F.Tag.Model Group.Type Name
Model Group Tag - Click for more information
F.Tag.RVTLink.Type Mark
RVT Link Tag - Click for more information
F.Tag.Specialty Equipment
Specialty Equipment Tag - Click for more information
F.Detail Items.Approach Arrow
Approach Arrow - Click for more information
F.GANN.Centerline.Non Parametric
Centerline - Click for more information
F.Tag.Elevation Marks.Interior
Interior Elevation Mark - Click for more information
F.Tag.Window
Window Tag - Click for more information
F.Tag.Column
Column Tag - Click for more information
F.GMOD.Clear Floor Space.Rectangle