Information related to electronic device fabrication is summerized here
Laser: SuperK COMPACT (see below for reservation calendar since the laser is shared with other optical setups)
Monochromator: SP-2155 (Teledyne Princeton Instruments), Grating (1: mirror, 2: 150g/mm, 800nm blaze)
Probe station: Riko Boeki vacuum prober
Galvano mirrors:
Objective:
Laser: SuperK COMPACT (see below for reservation calendar since the laser is shared with other optical setups)
Diode laser: CPS532 (Thorlabs)
Longpass filters: FELH1300,1400,1500 (Thorlabs)
Variable longpass filter: FELHV2 (Thorlabs)
Polarizing beam splitter: CCM10 PBS254/M (Thorlabs) mounted on KM100B/M
ND filter: NDL-25C-2 (Thorlabs)
Linear stage1: OSMS20-35(X)-M6 (Optosigma)
Linear stage2: Home-made (LS1002-220-T42-MP2, Misumi; Arduino R4 Minima; Stepper motor (no brand); A4988 driver)
Objective lens: M-PLAN NIR B 50X (Mitsutoyo)
Shutter: C-mount Electrical Shutter, #87-208 (Edmund Optics), controlled by NI DAQ USB-6001 and SSR (G3RZ-201SLN DC5) (Omron)
Translation stage: Zaber (T-NA08A25) * 3 mounted on Newport XYZ stage (M-460A-XYZ)
LED: SZX2-ILLC16-LED-SET (Evident)
Camera: EOS Kiss xx? (Canon)
LabVIEW (NI)
Laser: SuperK COMPACT (see below for reservation calendar since the laser is shared with other optical setups)
Diode laser: CPS532 (Thorlabs)
Shortpass filters: FESH1000??? (Thorlabs)
Monocrometor: SP-2155-GM (Teledyne Princeton Instruments), Grating: 150 G/mm balzed at 800 nm
Optical fiber & Collimator:
Galvano mirrors: GVSK2-JP (Thorlabs), controlled through NI DAQ USB6001
Power meter: S120C (Thorlabs), PM100USB? (Thorlabs)
ND filter: NDL-25C-4 (Thorlabs)
Linear stage: Home-made (LS1002-100-T42-MP2, Misumi; Arduino R4 Minima; Stepper motor (no brand); A4988 driver) to control ND filter
Objective lens: M-PLAN APO 20X (Mitsutoyo)
Shutter: SH1/M(Thorlabs), controller: SC10 (Thorlabs)
Translation stage Z: (Optosigma)
Photodetector: (Thorlabs), signal read from home-made voltage reader
Semiconductor parameter analyzer: S4156C (Agilent or Keysight)
Vacuum prober:
Lock-in amplifier:
Oscilloscope:
Transimpedance amplifier: AMP145 (Thorlabs)
LED: LA-HDF108AA (HAYASHI-REPIC) *for imaging by the camera
Camera: (Omron)
LabVIEW (NI)
F5112 Reservation System: https://www.if.t.u-tokyo.ac.jp/F5112_rsv/
Environmental Science Center: https://www.esc.u-tokyo.ac.jp/
武田先端知ビル: https://nanotechnet.t.u-tokyo.ac.jp/
CR wiki: https://nanotechnet2.t.u-tokyo.ac.jp/wiki/Main_Page
東京大学マテリアルリサーチインフラ・データハブ拠点: https://arim.t.u-tokyo.ac.jp/