Desired Outcome:
Safe, reliable, and efficient operation of the appliance maintained
SWS Detail: 7.0302.2 Fuel-Fired Storage Tank Water Heater
Author: Dalton
Before
After
Steps
- Qualified professional
Work shall be completed by a licenced and RMGA certified HVAC professional where required
2. Visual inspection
Inspect the water heater for the following: Water or fuel leaks, P&T valve ( piped within 6" of the floor), gas shutoff (should be able to turn by hand), venting issues, damaged wiring, corrosion, flame rollout, general condition of components.
3. Verify & adjust gas pressure
Verify the inlet and outlet gas pressure(s) are within manufacture specs.
4. Clean the burner
Make sure all soot and other obstructions are removed from the burner plate
5. Clean the burner chamber
Vacuum out the burner chamber removing any particles
6. Post - Draft & combustion testing
Conduct a Worst Case draft test to verify Category I, II, and III appliances are venting safely before leaving home for the day.
Testing shall be recorded using the Utah WAP Worst Case Draft Test form.
7. Fill out checklist
Fill out the Water heater safety checklist and place a copy on the client file.
8. Green Sticker the appliance
Fill out and post a Green Sticker per the Good Practices guide