Pre-procedure Preparation:
Tray must be opened and set up in OR, not in VIR
Standard tray (including contrast & saline syringes)
VIR blue towels and 4 x 4 gauze sets must be removed and replaced with OR towels (1 pack of 4) and raytecs (1 pack of 10)
One bowl with saline
NO LIDOCAINE
Since the tray is opened in the OR, there is no need to place a sterile cover after the initial set-up – leave it on the table for later.
Remove large drapes, half sheets, chuk, sterile II covers, etc.
Keep 3 - 4 pairs of 6.5 green gloves in the cart.
Access:
Ultrasound w/ linear probe + probe cover
5-F micropuncture set x 2
035-inch Bentson guide wire
6-F, 10-cm sheath x 2
Pressurized flush bag set-up x 2
2-0 Ethilon suture x 2
Procedure:
5-F Cobra-2 catheter
150-cm Glidewire + torque
5.5-Fr Fogarty balloon catheter x 2
1-way stopcock x 2
100 mL contrast medium
Tegaderm x 6 (poptart size)
Closure:
6-F Mynx x 2
Backup Supplies:
Prepare the below items but please do not open.
5-F, pigtail-tip OmniFlush catheter
Gelfoam
3-way stopcock
Extra gowns & gloves