SWS Detail: 7.0302.2 Fuel-Fired Storage Tank Water Heater
Work shall be completed by a licenced and RMGA certified HVAC professional where required
Inspect the water heater for the following: Water or fuel leaks, P&T valve ( piped within 6" of the floor), gas shutoff (should be able to turn by hand), venting issues, damaged wiring, corrosion, flame rollout, general condition of components.
Verify the inlet and outlet gas pressure(s) are within manufacture specs.
Make sure all soot and other obstructions are removed from the burner plate
Vacuum out the burner chamber removing any particles
Conduct a Worst Case draft test to verify Category I, II, and III appliances are venting safely before leaving home for the day.
Testing shall be recorded using the WAP Worst Case Draft Test form.
Fill out the Water heater safety checklist and place a copy on the client file.
Fill out and post a Green Sticker per the Good Practices guide