如何把MSM無線控制器 設定成 原廠初始值

Post date: Dec 28, 2011 3:13:45 AM

Using the Console (serial) port (MSM730/750/760):

    1. Power off the controller.
    2. Connect a serial cable to the controller console port.
    3. Configure a console client such has Tera Term Pro, PuTTy or Minicom as follows:
        • Terminal VT-100 (ANSI)
        • Speed 115200 for MSM730/750, 9600 for MSM760
        • Data bits: 8
        • Stop bits: 1
        • Parity: none
        • Flow control: none
    1. Open a terminal session.
    2. Power on the controller. One will see system boot messages on the console screen.
    3. Wait for the LILO prompt to appear. The prompt looks like this:
      1. LILO 22.1 boot:
    4. At the LILO prompt type command linux factory . The device will boot with default settings.

Via the CLI interface (MSM765zl only):

    1. Connect to the CLI of the switch hosting the controller.
    2. Give command: services <module> <ID> to access the CLI of the module.
      1. Example: services d 2
    3. Give command: enable
    4. Give command: configure
    5. Give command: factory settings

祝各位網路暢行無阻