如何把MSM無線控制器 設定成 原廠初始值
Post date: Dec 28, 2011 3:13:45 AM
Using the Console (serial) port (MSM730/750/760):
- Power off the controller.
- Connect a serial cable to the controller console port.
- Configure a console client such has Tera Term Pro, PuTTy or Minicom as follows:
- Terminal VT-100 (ANSI)
- Speed 115200 for MSM730/750, 9600 for MSM760
- Data bits: 8
- Stop bits: 1
- Parity: none
- Flow control: none
- Open a terminal session.
- Power on the controller. One will see system boot messages on the console screen.
- Wait for the LILO prompt to appear. The prompt looks like this:
- LILO 22.1 boot:
- At the LILO prompt type command linux factory . The device will boot with default settings.
Via the CLI interface (MSM765zl only):
- Connect to the CLI of the switch hosting the controller.
- Give command: services <module> <ID> to access the CLI of the module.
- Example: services d 2
- Give command: enable
- Give command: configure
- Give command: factory settings
祝各位網路暢行無阻