See blueprint page 104 for electrical layout
See blueprint page 106 for cabinet layout for centering and measurements
Image 1
Outlets in master bath area must be outside the mirror area (65" from door way wall)
Image 2
Guest bath must be installed on the door way wall
Image 3
Light switches must be installed in a way that will not be blocked by door swing at final
Image 4
Soffit for floodlight must be installed on corner of porch closest to the parking area
Image 5
A, B, C plan breaker location is in the laundry room. G plan is in the garage. F plan confirm with Superintendent and Project Manager
Image 6
Smoke detector must be installed 3' from any HVAC supply and return vents and fan blade edge
Image 7
Meter base is installed at 5'6" to meter location from final grade
Image 8
Meter base height to center of meter must be 5'6" to center of meter
Image 9
All electrical penetrations through exterior walls must be fully sealed with silicone
Image 10
5" nail guard plates are installed for all HVAC/electrical/plumbing lines within 5" of the edge of the top or bottom plates
Image 11
Electrical outlet for washer on left and outlet for dryer on right
Image 12
Light fixture in crawlspace must be placed in a non intrusive area and within sight of water heater
Image 13
Front porch flood light location: stair side, far cornerĀ
Image 14
Front porch overhead light locations
Image 15
Front porch door light locations
Image 16
Door bell speaker location
Image 17
Microwave outlet location is 42 1/2" from deck side wall
Image 18
Microwave outlet location is 26 1/2" from top plate
Image 19
Kitchen layout light location
Image 20
Pantry light location
Image 21
Under cabinet LED
Image 22
Stairwell light switch location
Image 23
C plan stairwell light above landing is a shallow can light
Image 24
Fire blocking must be done on all floor and exterior wall transitions including stairs
Image 25
Distance measurement from doorway wall for master bath vanity
Image 26
Distance measurement from ceiling for master bathroom vanity lights
Image 27
Half bath outlet location and light measurement C Plan
Image 28
Half bath light location distance from ceiling
Image 29
Outlet for laundry washer is installed
Image 30
Outlet specific to laundry dryer electrical connector must be installedĀ
Image 31
Outlet specific to oven/range electrical connector must be installed