APU Fire Bottle
APU Fire Bottle
AMM Ref: 26-22-41
Consumables: As per AMM
1) LST , CFC & Rag pieces
2) Locking wire (thick/thin)
Tools:
1) Shunt # Qty-01
2) Apex bit # No.10
3) Torque wrench# 200 in-lbs
4) Adjustable wrench 18" or Monkey plier
5) Speed handle
6) Socket # 9/16
7) Spanner # 3/8
8) Common tools
Support Equipments:
1) APU Trestle
Precautions/Tricks: As per AMM
1) For opening cartridge assembly from fire bottle, turn the big nut clock-wise.
2) During opening of access panel of APU Fire Ex. bottle, ensure no anchors are missing/damage, if yes then immediate call Structure Technician for replacing same.
Warning: Always use updated AMM/IPC,Task card, etc. for performing any work on aircraft .