Components of a Basic Hydraulic System

Components of a Basic Hydraulic System

·

Figure 1: Basic Hydraulic System

A basic hydraulic system will have a pump, a pressure control valve, one or more control valves, one or more pistons or hydraulic motors that transfer the hydraulic power into motion and a return system that collects the low-pressure hydraulic fluid and feeds it back to the pump for re-use. See an illustration of this system in Figure 1. This article focuses on the hydraulic control valve illustrated in Figure 1.

Basic Hydraulic Valve

·

Figure 2: Basic Hydraulic Valve

Hydraulic valves are often called spool valves because the moving part of the valve is reminiscent of a spool of thread. The design of a hydraulic valve allows it to control both the supply and return lines on the equipment being operated. This way it is able to operate equipment in both directions by reversing the high pressure and low pressure connections. The spool is attached to levers or a solenoid that position it to operate the equipment.

Operating the Hydraulic Valve

·

Figure 3: Operating the hydraulic valve

When the operator wants to raise his truck he moves the operating lever so that the illustrated valve spool moves to the right. This connects the high pressure to the bottom of the cylinder, lifting the dump on the truck. It also connects the top of the cylinder to the return line so that hydraulic fluid can be pushed out and return to the tank. This is illustrated in Figure 3.

Reversing the Hydraulic Valve

·

Figure 4: Reversing the Hydraulic Valve

After the load has been dumped, the operator moves the spool in the opposite direction as shown in Figure 4. This connects the high pressure hydraulic fluid to the top of the cylinder, pushing it down, and allows the oil at the bottom of the cylinder to return to the tank

How Do Hydraulic Valves Work?

Basics

1. Hydraulic valves are valves used to move hydraulic fluid where needed in hydraulic equipment. They are similar to general valves in how they work. The valves control the flow and pressure of the fluid so that the equipment can work properly. Valve types for hydraulic equipment can be as simple as an on off type to those that control flow to a precise degree.

Parts

2. All the valves have basic components. There is the main casing, a bonnet, a seat and a disc. Some valves will have multiples of these components, while others might have only one. The main casing is the outer shell of the valve. The seat is where the valve is connected. The bonnet is the part of the outside casing that can be removed to do repairs on the valve. The disc is the seal that keeps the valve from leaking at the point of connection to the hose.

Inside

3. The inside parts of hydraulic valves can range from a tapered cylinder that can regulate the amount and pressure of the fluid passing through to port type valves that can do little more than turn on and off. Some valves have a split and can send fluid in more than one direction at once or alternate flow. These are directional valves. Many hydraulic valves will have a backflow preventer to keep fluid from moving back up the wrong direction.

On and Off

4. Hydraulic valves can be turned on and off by hand or some other type of machine control. In some cases a hydraulic control turns the valve on and off. In the case of a float valve, the float is the control. A switch is set off by the float. When the fluid moves up to a set point the float in the valve is forced up to hit a trigger that allows fluid to flow. When the fluid moves through, the floats starts back down. When it reaches a certain low point the valve turns back off.

How Do Hydraulic Spool Valves Work?

Hydraulic Spool Valve Basics

1. A hydraulic spool valve is a switching device used to control hydraulic devices. Spool valves are used in everything from automotive power-steering systems to cranes. A spool valve can turn the flow of hydraulic fluid from a hydraulic pump to an actuator on and off by blocking off the route the fluid takes.

Hydraulic Spool Valve Structure

2. A hydraulic spool valve is a cylinder inside a sealed case. It usually has valves leading to the pump and the tank on one side, and valves leading to one or more hydraulic devices on the other side. Pressure can flow into the valve from the pump into the hydraulic devices, or drain out of them back into a hydraulic storage tank. A controller moves the valve back and forth in its case to slide the spools into different positions. The position of the rotor will only allow the hydraulic fluid to flow in one direction to perform a specific task.

Moving a Hydraulic Piston

3. Hydraulic spool valves can be used in many different ways to perform many different functions. One of the most common uses is to drive a pressurized hydraulic piston. The piston is sealed in a cylinder with a valve on either end, both leading to the the spool valve. When the spool valve is set in the "push" position, fluid flows from the pump into the bottom of the cylinder while the fluid in the top of the cylinder is allowed to flow out into the hydraulic tank. This pushes the piston out. When the valve is set in the "pull" position, fluid flows into the top of the cylinder and out of the bottom, causing the piston to pull back into cylinder. Check out the link below to see a spool valve moving a piston.

Proportional and servovalves

Infinitely variable directional control valves

The directional control valves discussed so far in this series have all been configured to either pass full flow or completely block flow. The only way to decrease flow through these valves is by adding flow controls or by mechanically limiting movement of an internal part.

The first infinitely variable valve available was the servovalve. Internal flow-modifying parts could be moved to any position at any rate, so output from any port could be varied at will. (Some call these valves infinitely variable 4-way flow controls.) The main problem with servovalves was (and still is) that they require very clean fluid to keep them operating effectively. Fluid from a standard well-maintained hydraulic circuit contains enough contamination to cause most servovalves to fail in a matter of minutes or only last a few hours at best. This meant that the original servovalves were tried and removed from many machines that needed precise control but not at the perceived cost of cleaning up the hydraulic oil.

Why use infinitely variable valves?

Some actuators must move at a precise speed, stop at a close-tolerance position, or produce a very accurate force to perform the work for which they were designed. With the proper input signals and feedback devices, proportional or servovalves can make an actuator perform any or all these functions flawlessly.

Rolling mills turn out sheet consistently to a tolerance of ±0.0005 in. at sheet speeds of 2000 to 5000 feet per minute. Hydraulic cylinders controlled by servovalves maintain the proper force and position the rolls precisely from feedback signals sent by sensors that measure metal thickness, cylinder force, and position. Airline pilots train in simulators moved by hydraulic cylinders so precisely that the pilots get the feel of landing gear raising and locking in position. Even entertainment rides use servovalves to make passengers think they are in 20-ft waves when they are actually in an enclosed articulated room in a shopping mall.

For less precise movement, there are proportional valves that mimic the output of servovalves but respond more slowly. They are less expensive than servovalves and more contamination tolerant, so they have replaced cam valves and other mechanical devices used to get smooth motions.

Hydraulic proportional directional control valves

The symbol and cutaway view in Figure 12-1 represent a direct-acting proportional valve that handles flows as high as 10 to 30 gpm in D03- or D05-size valve interfaces. Proportional valves use the same interface standards as NFPA and ISO directional valves so they can be installed in a circuit without having to change the piping.

Fig. 12-1. Direct-acting proportional valve


Physically, proportional valves appear the same as their on/off solenoid counterparts. The big difference is in the way their solenoid coils perform. Proportional coils operate on DC current and produce varying force with varying voltage. The symbol shows the solenoid slash in the operator box with a sloping arrow through the slash. This indicates the solenoid has variable force that moves the spool more or less as voltage increases and falls. The other indication on the symbol that shows the spool is infinitely variable is the parallel lines down both sides of the boxes. Proportional valves operate similarly to manual valves, but they use electronics instead of hand power.

To eliminate flow lag from spool overlap, most manufacturers cut vee notches or use some similar method that allows some flow to pass as soon as the spool moves. Vee notches also give smooth flow buildup until the spool moves through the land overlap.

Proportional valves only have two center configurations (as shown by the symbols in Figure 12-1). This means that pressure-compensated pumps with accumulators normally power circuits with proportional valves. The circuits are pressurized at all times to produce fast response from an actuator when motion is called for. (A pressure-compensated circuit also wastes the least amount of energy when throttling flow.)

The valve in Figure 12-1 depends on a certain voltage to move the spool a certain distance to pass a certain flow. This works reasonably well, but is not accurate over a broad range of pressures, flows, and temperatures. Most valves of this design are used to smoothly accelerate and/or decelerate an actuator. The spool is electronically controlled to shift over a period of time to increase flow at a controlled rate. Spool-shift speed can be controlled electronically as it opens and closes to give smooth acceleration and deceleration. Spool-shift distance can also be limited electronically to set a maximum speed when required.

Fig. 12-2. Direct-acting proportional directional control valve with spool-position feedback transducer


To give better spool control, a linear variable-displacement transducer (LVDT) is added to the basic valve. The cutaway view and symbol in Figure 12-2 represent a direct-acting valve with an LVDT. Feedback from the LVDT tells the electronic controller the spool’s position and makes sure it goes to the same place when it receives the same signal. With this arrangement, the spool always shifts to an exact location and opens the same size orifice so it can pass the same flow when pressure drop and viscosity stay the same. Control of flow is more accurate with an LVDT but pressure drop does not stay constant and viscosity often changes throughout the day so speed variations are still apparent. Such flow variations caused by system pressure fluctuation can almost be eliminated by the addition of a hydrostat module in port P as shown in Figure 12-3.

Fig. 12-3. Direct-acting proportional directional control valve with LVDT and pressure-compensating hydrostat module


A hydrostat is simply a pressure-reducing valve set to hold downstream pressure in a 100- to 150-psi range. However, a hydrostat has a pilot line from a shuttle valve that reads downstream pressure at ports A and B, then feeds it back to the bias-spring end of the spool that controls the 100 to 150 psi. The function of a hydrostat is to maintain a constant pressure drop across the spool orifice so flow stays constant regardless of changes in system pressure. (For a thorough understanding of how pressure compensation works, see the pressure-compensated flow control valve section in Chapter 13.)

With the addition of a hydrostat, actuator speed is controlled as accurately as possible without a closed-loop electronic circuit that reads speed and modifies spool position. Closed-loop electronic circuits are used with proportional valve systems, but they only give nominal control. When accurate control is required, use servo valves with closed-loop electronics.

The symbol and cutaway view in Figure 12-4 is for a proportional valve that only controls flow. Such valves are commonly called throttle valves because they are not pressure compensated unless a hydrostat module is added.

Fig. 12-4. Direct-acting proportional throttle valve with spool-position feedback transducer


Basic operation is identical to the proportional control valves just discussed. The only difference is they have a single solenoid and may be piped with dual flow (as shown). Dual-flow piping allows a given size valve to pass twice the volume at the same pressure drop. It can be used with any 4-way directional control valve with one precaution: the valve must be capable of handling maximum system pressure in its tank port. Many wet-armature valves will not operate at full rated pressure at their tank port. Check the supplier’s catalog to see what maximum tank line pressure is allowed. Air-gap solenoid valves and solenoid pilot-operated valves with external drains normally allow full rated pressure in the tank port.

The circuit in Figure 12-5 shows a possible use for a proportional throttle valve. The vertical-down acting cylinder with a platen needs speed, acceleration, and deceleration control. This could be done with a 4-way proportional valve, but the circuit uses an inline or screw-in cartridge valve that is not directly replaceable. Adding a proportional throttle valve to the tank line of the present 4-way circuit can give the required control without extensive piping changes. The circuit is shown using a single flow path for low volume. A dual flow path setup (like the one in Figure 12-4) would allow as much as twice the flow. As stated earlier, make sure the 4-way directional control valve can accept tank-line backpressure without damaging it or causing a malfunction.

Fig. 12-5. Typical circuit using a direct-acting proportional throttle valve with spool-position feedback transducers


If the cylinder had a resistive load, the proportional throttle valve could be placed in the pump line of the 4-way as a meter-in flow-control circuit. A meter-in circuit would not damage the directional control valve or cause it to malfunction. The circuit in Figure 12-5 could have a counterbalance valve in the rod-end line to make it resistive. (See Chapter 14 for counterbalance valve operation and applications.)

The platen would start to move at a controlled rate when the 4-way valve shifts and the proportional throttle valve is signaled to open slowly. The shift time for the throttle valve determines the acceleration time, while shift travel distance determines maximum cylinder speed. Cylinder speed would be infinitely variable to match any production need.

Near the end of the stroke, a slowdown limit switch would signal the proportional throttle valve to start shifting back to its closed position. The proportional throttle valve would close at a controlled rate and flow from the cylinder would be retarded smoothly. When the cylinder slows sufficiently, it contacts the end-of-stroke limit switch and the 4-way directional control valve shifts to center to stop it.

The circuit in Figure 12-5 would only hold position if some retract signal was applied when stopped. This is due to internal leakage by the spool of the 4-way directional control valve and the proportional throttle valve. Another option would be to use a float-center directional control valve and a counterbalance valve.

Proportional valves for flows higher than 25-to-30 gpm use solenoid pilot-operation similar to conventional directional control valves. A small pilot-operated valve receives a signal and then sends hydraulic oil to proportionally move a larger control spool that controls actuator movement.

The cutaway view and symbol in Figure 12-6 depict a typical solenoid-pilot valve arrangement. A reducing valve module, between the pilot operator and the pilot-operated valve, keeps maximum pilot pressure below 200 psi. A proportional Input to one of the coils on the pilot operator directs flow to the spool of the pilot-operated valve and shifts it against a spring. As pressure against the spool increases, it shifts farther and sends more flow to the actuator. Feedback signals from both spools tell the electronic controls that the command has been carried out. A vee-notched spool allows flow to increase at a smooth rate so actuator speed is consistent throughout the speed range.

Fig. 12-6. Solenoid pilot-operated proportional directional control valve with spool-position feedback transducers


Ports for internal or external pilot X or drain Y provide options for these control lines to meet a particular requirement.

The complete symbol is shown in Figure 12-6. (For the simplified symbol, see Chapter 4.)

Flows up to 200 gpm are common for a D10-size proportional valve. For higher flows, use slip-in cartridge valves (discussed in Chapter 11) with proportional operators.

Hydraulic servo directional control valves

Proportional control valves are infinitely variable but they are neither highly responsive nor capable of handling minute flow changes rapidly and accurately. On the other hand, servovalves easily meet both of these requirements . . . but at a cost. They are more expensive than proportional valves, they require super-clean fluid, and they need extra electronics to exploit their full capabilities.

The three common servovalve types are flapper, jet pipe, and mechanical. Each design has advantages as far as operation accuracy, leakage, contamination tolerance, and price. They range in flow capacity from less than 1 gpm to more than 1000 gpm. Most manufacturers make valves that operate at 3000 psi, but some offer valves at 5000 psi.

The main difference between proportional and servovalve circuit design is that servo systems have a method of feedback that assures that the actuator is doing what the controller tells it to do. A super-simple form of servo control would be a backhoe operator moving manual valves to cause a bucket to move toward him at a given rate. Feedback from the operator’s eyes would tell his hands when and how far to move the levers to give more or less flow to maintain the action he wants. Other familiar mechanical feedback examples are hydraulic driven power steering and hydraulic power brakes on a vehicle.

The circuit in Figure 12-7 is an example of a working circuit with mechanical feedback that controls a hydraulic press. The operator needs to have a feel for the motion of a platen as it cuts through some tubing. Originally this was done with an arbor press, but it was hard for the operator to keep up with production due to the physical exertion. Now all the operator has to do physically is overcome the spring force of the manually controlled mobile directional valve to make the platen move. As the platen moves, the directional valve body also moves, so the operator has to keep moving the lever to advance or retract the platen. Notice the mechanical link between the valve body and the cylinder rod that moves the valve body at the same rate the cylinder rod moves. The operator now has a hydraulic force multiplier that gives some feel to what he is doing.

Fig. 12-7. Simple mechanical servo system for force multiplication


The reason for using a mobile-type valve is because those valves have less spool overlap and the spool has notches cut in it. The notches pass a small flow almost immediately when the spool moves. That flow increases in proportion to spool movement.

Most industrial applications use feedback from electronic linear, rotary, or force transducers. A transducer is a device that produces an electrical signal in direct relation to a position, force, or speed.

Linear potentiometers work for short strokes (12 in. or less). Longer strokes require a device such as a Temposonics transducer. In either case, these devices feed a precise position or speed indication back to an electronic controller.

For rotary motion, an encoder or similar device that produces multiple pulses per revolution sends a signal about rpm or angle of rotation to the controller.

When information about force is required, a load cell sends the data to the controller.

With these very accurate feedback devices and a fast-response servovalve, an actuator’s position, speed, and/or force can be repeatedly established within an extremely close range. Electronics provides the accuracy while hydraulics provides the force via a super-responsive servovalve.

The cutaway view and symbol in Figure 12-8 show a less-responsive but more contamination-tolerant servovalve. There are other mechanical ways of driving the spool. The valve in Figure 12-9 uses a rotary drive and an eccentric to move the spool left or right to an infinite number of positions. Because the drive is quite strong and there are no orifices to clog, this valve can operate with fluid that meets ISO Code 4406 20/16/13.

Fig. 12-8. Rotary-drive servovalve


Notice the difference in design between spools in proportional valves and servovalves. Most proportional valves use spools with overlap and some sort of notches that pass flow while moving out of overlap. A servovalve has no overlap or underlap of the spool lands to the body lands. (One manufacturer calls it “Critical lap” because all points blocking fluid cannot move without passing flow.) This spool design makes the valve very responsive (as well as very expensive and prone to above average bypass). Servovalve spools and bodies always come in matched sets because of their close fit and four points of land-to-land match.

The rotary-drive eccentric valve pictured in Figure 12-8 has fast, controllable spool movement from a rotary drive that incorporates a feedback loop. When the drive receives a signal to move the spool to pass a certain flow, a position feedback output sends a signal back to the controller when the motion is complete. There is still feedback from the actuator that what was commanded is happening, so spool position can be changed via the electronic feedback and controller as necessary.

Several factors determine when a given input will not produce the desired actuator output. The main factor is actuator load. As load changes, input force must change -- by allowing more or less fluid into the circuit. Fluid viscosity also has an effect, so the flow path must be reduced as viscosity lowers and enlarged as viscosity rises. Then there is system pressure. As pressure fluctuates, flow across the spool orifice changes. The higher the pressure drop, the greater the flow. Because a servovalve circuit has feedback from the actuator, it can adjust flow or pressure to match system changes continuously.

Figure 12-9 shows another mechanically driven servovalve. This setup works for cylinders and hydraulic motors, but must be directly attached to the actuator (as shown) or driven by it with a toothed belt and pulleys. This is a very contamination-tolerant valve arrangement because the stepper motor is quite strong and there are no small orifices to clog. The spool has no overlap or underlap so any movement immediately initiates fluid flow to and from the cylinder. The piston and rod cannot rotate so the feedback screw turns as the piston extends or retracts.

Fig. 12-9. Stepper-motor-driven servovalve with mechanical feedback


As the stepper motor turns, a threaded rod inside the threaded spool moves the spool to direct fluid to extend or retract the piston. When the cylinder piston moves, the feedback screw turns the spool back on the threaded rod to counteract the stepper motor shift. When the stepper motor turns, the piston moves at a speed proportional to the stepper motor’s rpm. When the stepper motor stops, the piston catches up and stops also. Manufacturers claim a tolerance of ±0.001 in. repeatability. If an external force tries to push or pull the piston out of place, the feedback screw shifts the spool and fluid starts resisting movement.

From the foregoing explanation, it is easy to see how this valve – when attached to a hydraulic motor -- would give an exact number of turns and repeatedly cause the motor to stop at exactly the same place. This will happens even if the hydraulic motor has internal leakage. The only time the actuator gets out of place is when it cannot overcome the load and stalls. The stepper motor continues to receive pulses, but it also stalls when the spool shifts all the way. The stepper motor received a signal that should have placed the actuator at a certain distance but the actuator did not get there because of insufficient force. When the valve reverses, it starts its motion from the wrong point and will overshoot home position as it returns. A limit switch at the home position can alert the controller that there is a problem when the actuator overshoots -- and prevent the machine from producing scrap.

The jet-pipe servovalve pictured in Figure 12-10 also tolerates contamination due to a control orifice that is large enough to pass large particles. Pilot oil is tapped off the system fluid inlet, sent through a coarse filter, and on to the jet pipe that terminates in an orifice. The orifice outlet is centered over the inlet of two passages that terminate at each end of a critical-lap spool. Flow into these passages puts equal pressure on both ends of the spool as the feedback wire holds it centered. Current signals to the coils cause the armature to rotate and shift more of the output of the jet pipe to one passageway than the other. Pressure increases on one end of the spool and decreases on the other end. As the spool shifts, it starts to pass flow to the actuator at a rate set by the input electrical signal.

Fig. 12-10. Jet-pipe servovalve


When the jet pipe shifts to the left, the spool moves to the right. At the same time, the feedback wire also moves to the right, pulling the jet pipe nozzle back to center and stopping spool movement. A given input to the coils electromechanically shifts the armature that moves the jet pipe. This moves the spool hydraulically and forces the jet pipe back to center mechanically through the feedback wire.

A measured electrical input to a servovalve produces a fixed flow output, similar to a proportional valve. This control alone does not give much better control than a proportional circuit even though the valve is more responsive. There is still no compensation for viscosity or pressure changes that can cause the actuator’s speed to fluctuate. To overcome this problem, some sort of electronic feedback from the actuator is necessary. The feedback signal through an electronic circuit board modifies the signal to the servovalve to make the actuator perform as planned. Actually, the electronics do the work as long as the valve can respond quickly enough to keep everything working at the correct rate. This means the spool must be free enough to move easily without excessive bypass. Anytime the spool moves, it should pass flow to and from the actuator.

The valve in Figure 12-10 is considered a 2-stage valve. The first stage is electronic and receives an electronic input signal, while the second stage is fluid powered by a hydraulic signal.

The jet-pipe servovalve depends on clean oil for long trouble-free operation -- not as clean as the requirement for the flapper-valve design discussed next, but clean enough to prevent the jet-pipe nozzle from clogging. It is obvious that once nozzle flow is retarded enough or stops, the valve loses all ability to control flow to the actuator.

The most responsive and accurate servovalve design is the flapper valve, shown in Figure 12-11. This design is the least tolerant of contamination because it depends on very small orifices for fast response with minimal wasted energy. It is called a flapper valve because the element that holds equal pressure on both ends of the spool at rest reminds one of a flapping device. It is a 2-stage valve with an electronically controlled torque motor as the first stage and a pilot-operated spool as the second stage. As in all servovalves, the spool has no overlap or underlap that would make it sluggish or bypass a lot of fluid unnecessarily.

Fig. 12-11. Flapper-design servovalve


Fluid from the pump inlet is tapped off through rather-coarse filter elements, passes through orifices past both ends of the spool, goes on to nozzles, and out to the return line. The orifice diameters are slightly larger than the nozzle diameters, so there is a pressure buildup at both ends of the spool. A feedback wire attached to the flapper terminates in a ball end that sits in a very close-fit slot in the spool. A sleeve around the spool can be moved left or right by a null adjustment to align the spool and body lands perfectly when the valve is first installed. (Usually null adjustment is only required at startup of the valve.)

The null adjustment usually is a hexagonal wrench fitting attached to an eccentric pin located in the sleeve slot. With the null adjustment centered, turning it one round moves the sleeve from center to full right, back to center to full left, and back to center. If the valve cannot be nulled within one rotation of the null adjustment, replace it and send it in for repair. This usually indicates a clogged orifice or nozzle controlling one end of the spool.

Unplug the electrical supply to the valve before setting null. Start the pump and watch for actuator movement. If the actuator moves, loosen the null lock screw and carefully turn it. Observe whether the actuator slows or picks up speed. A nulled valve stops actuator movement because the forces on both sides are equal. High-flow 3-stage valves cannot be nulled to the point of stopping an actuator due to the piloted spool slipping by the stop-flow position as the pilot operator is adjusted. When null is set, lock the null screw and reattach the electrical plug.

Turning the null screw with the electric plug detached is one way of moving an actuator manually. This might be done to prove the valve is working properly and the problem is electrical.

When the torque-motor coils receive a current signal, the armature rotates clockwise or counter-clockwise and pushes the flapper closer to one nozzle and farther away from the opposite one. This allows pressure to increase at one end of the spool and decrease at the other. The spool then starts to move away from the higher pressure. If the armature turns clockwise, pressure builds on the left end of the spool and it moves to the right, as shown in the left cutaway view of Figure 12-12.

Fig. 12-12. Flapper-type servovalve shifting from an electrical input signal


As the spool moves to the right, it also drives the feedback wire to the right. The feedback wire is strong enough to overcome armature force and pull the flapper back to center. After the flapper centers, pressure is equal on both ends of the spool and it stops. More current to the coils causes more rotation and additional spool shift until the feedback wire again centers the flapper.

From the foregoing explanation, it is obvious why this valve needs clean oil. If an orifice or nozzle clogs, the spool shifts all the way to one end and the actuator moves until it runs into a resistance it can’t overcome. Also, the spool must start shifting at a very low pressure drop across it to keep response high. Contaminated fluid can cause sticking and require high differential shifting pressure that makes spool movement erratic.

For flows above 60 to 80 gpm, a 3-stage servovalve is required. It consists of a small 2-stage pilot operating a large pilot-operated spool, as depicted in Figure 12-13. The 2-stage valve operates as just explained, but its output goes to move a pilot-operated spool in the third stage to a precise position to control high flow to large actuators.

Fig. 12-13. Three-stage flapper-type servovalve


An LVDT signals the electronic control circuit that the pilot-operated spool is where it was signaled to go. After receiving that position signal, the 2-stage valve shifts to no flow or whatever flow it takes to keep the pilot-operated spool in place.

A 3-stage valve also depends on feedback signals from the actuator to modify the input signal when the action is not in compliance with the command. This makes 3-stage valves very accurate controllers of large cylinders.

Pneumatic proportional and servo directional control valves

Since the late ‘80s, several companies have been controlling air cylinders with open- and closed-loop proportional or servovalve circuits. The difference between the air valves in these circuits is how fast they respond. Most proportional valves have a sealed spool that controls direction and flow so the valves tend to hang up and jump. Pneumatic servovalves often have spools with metal-to-metal fits that float on bypass air.

The valve shown in Figure 12-8 is sold as a proportional or servo directional control valve for hydraulic or air circuits. Controlling the amount of air and which direction it goes is not a problem but the compressibility of air creates some giant hurdles to overcome.

Proportional valves usually control only acceleration, deceleration and/or speed because these circuits do not include feedback transducers. It is very easy to get smooth acceleration and deceleration with high speed in between without other controls or shock absorbers to stop the load mechanically.

Adding feedback transducers to a proportional air circuit can provide servo-like control for light loads -- such as those found in pick-and-place applications. However, a proportional valve is usually not responsive enough for exacting part placement or speed control. For very accurate control, a servovalve with feedback transducers can give close-tolerance positioning (with light loads), repeatable velocity control, and very accurate holding force.

Pneumatic proportional and servovalves are not a replacement for electromechanical or servo hydraulics, but they have price advantages over both systems. When the loads are light and cost is a factor, they are worth a look.

General information for hydraulic infinitely variable valves

· The symbol for proportional and servovalves shows a 4-way, 3-position function and the valve can move to each of the positions. However, the parallel lines along the sides of the symbol indicate the valve does not have to shift all the way all at once. These valves can shift into straight or crossed arrows in any proportion from 0 to 100%. They are infinitely variable and can pass any flow desired.

· servovalves are always 3-position, all-ports-blocked center condition, as shown by the symbols in Figures 12-8 through 12-11.

· always size proportional or servovalves for high pressure drop. Proportional valves should have 200- to 500-psi pressure drop at full flow. Most servovalve manufacturers rate their valves at 1000-psi pressure drop at full flow. This means the valve may look physically small for a given flow in relation to conventional valves. It also means most servo and proportional valve circuits require a heat exchanger to deal with excess wasted energy.

· always mount the valve as close as possible to the actuator ports. Any piping between the valve and the actuator holds extra fluid that can make the system softer and less responsive. This is especially important on air-powered circuits.

· never use hose between the valve and the actuator. If isolation is necessary, mount the valve on the moving part and use flexible lines for supply and return.

· use in-line pressure filters at the supply to each servovalve or bank of valves to protect the valve from contamination in the pump and piping.

Specific Information for pneumatic infinitely variable valves

· use air at the highest pressure possible that does not exceed component or plumbing limits. This is usually as high as 250 psi.

· size the valve to flow just enough to produce the maximum desired actuator speed. Oversize valves produce erratic control because a small spool movement gives more flow than required.

· use an actuator with the largest area practicable so the load moves with a low pressure difference. Note: the larger the cylinder, the more air it consumes so operating cost escalates.

· pneumatic servo circuits do not work well when outside forces push against the actuator. The actuator tries to resist, but force buildup is slow in comparison to electromechanical or electrohydraulic systems.

Typical servo circuits

Figure 12-14 shows schematic drawings of three typical servo circuits. In the figure, each type circuit controls a different actuator, but any actuator could have more than one type of control.

Fig. 12-14. Servovalve and closed-loop electronic circuit for accurate position, force, and speed control


The typical power unit for a servo system is a pressure-compensated pump with an accumulator or accumulators. A servovalve must always have a ready supply of fluid because no matter how fast it reacts, without an immediate supply of fluid the system will be sluggish. The pressure-compensated pump may be at full pressure when no actuators are moving, but its flow is zero. Adding accumulators assures that there is no wait for the pump to come on stroke before the actuator receives flow. (A full discussion of how accumulators work and how they are applied is in Chapter 16.)

Again, pressure filters in the lines to the servovalves make sure they receive clean oil. One filter could be sufficient for multiple valves when the valves are close to each other. The reason for pressure filters in the valve lines is the pump constantly produces contamination particles that will shut down flapper-type servovalves.

Cylinder 1 is in a position loop. It can be placed at a precise location repeatedly within ±0.0005 in. A programmable logic controller (PLC) sends a signal to the summing amplifier’s control card. The signal passes on to the valve-driver card and then to the valve coils. This signal shifts the servovalve to start cylinder movement at a set rate. The linear potentiometer sends position feedback to the summing amplifier and modifies valve position to find and maintain a certain position. Often, position control is paired with speed control to accelerate the actuator to a certain speed, then decelerate and stop it at the desired position.

Cylinder 2 is in a force loop. A certain size cylinder operating at a given pressure produces a given force. This force can be calculated by multiplying area times pressure, but the result is not exact. Friction from seals and between external machine members can reduce this force by a few pounds or more on an operating machine. When an exact force calculation is required, a servovalve-controlled cylinder that has a load cell for feedback can keep forces within 1/2% with ease. The summing amplifier sends a signal from the PLC and feedback from the load cell modifies the valve position to exactly match the input signal to generate the desired force.

The hydraulic motor is in a speed loop that maintains the motor’s rpm when the fluid viscosity, pressure, or load changes. A rotary device called an encoder constantly sends rpm information back to the summing amplifier to open or close the servovalve as needed. Just as a cylinder does, a hydraulic motor will slow when the load increases, when fluid gets thinner due to temperature increases, or when system pressure fluctuates as other actuators move. If the encoder sends a reduced-rpm signal back, the servovalve opens to let more fluid in. If the hydraulic motor tries to speed up, the servovalve closes enough to maintain the set speed.

Other infinitely variable valve applications

Proportional and servovalves can be applied to variable-volume pump controls to accurately set flow from the pump in relation to feedback from an actuator. Most pressure-compensated pumps available today have this feature as an option.

An example might be a closed-loop hydrostatic pump and motor that must stay at a constant speed. Feedback from an encoder signals the pump to increase or decrease flow as the motor overspeeds or underspeeds.

Proportional coils make excellent infinitely variable flow controls that can be controlled electrically. They can act as simple throttle valves or perform as full-blown pressure-compensated types that adjust to pressure fluctuations.

Common circuits for proportional flow controls include feed-speed changes to deal with load fluctuations; hydraulic motor rpm changes to control product backup; or maintaining constant speed as loads vary. (Pressure-compensated proportional flow control valves are covered in Chapter 13.)

Proportional coils also make excellent infinitely variable pressure-control valves. Pressure settings from remote locations or a PLC at anytime from minimum to maximum almost instantaneously. Most of these pressure controls are for relief and reducing functions but could be used on any of the pressure controls. (Proportional pressure-relief valves were covered in Chapter 9.)

Bang-bang is the term often used to describe basic directional-control valves. It refers to how the valves shift - from fully open to fully closed. This usually occurs in an instant, causing fluid to rapidly accelerate and decelerate. Under certain conditions, this can cause fluid hammer, which sounds like a hammer striking the hydraulic system from inside. Hence, shifting the valve from one position to another can produce a bang-bang sound.

A less informal term to describe these components is discrete valves. This term refers to how the valves operate: they shift from one discrete position to another, such as extend, retract, and neutral. Proportional valves, on the other hand, control direction and speed. In addition to shifting into discrete positions, they can shift into intermediate positions to control actuator direction, speed, acceleration, and deceleration.

Even more basic than the discrete directional-control valve is the digital valve. As in digital electronics, digital valves operate either on or off. Whereas discrete valves generally use a spool to achieve two, three, or more positions, discrete valves use a plunger, poppet, or ball that seals against a seat. The advantage to this type of operation is that it provides a positive seal to prevent cross-port leakage.

Perhaps the simplest of all directional-control valves is the check valve, a specific type of digital valve. Basic check valves allow fluid to flow in one direction, but prevent fluid from flowing in the opposite direction. As with all fluid power components, directional-control valves can be represented by standard symbols published in ISO 1219. Figure 1 shows a cross-section of a spring-loaded check valve and its ISO 1219 representation.

Fig. 1. Basic check valve allows fluid to flow in one direction, in this case from bottom to top. Shown are ISO symbol and cross-sectional photo of spring-loaded check valve. The spring keeps fluid from flowing unless downstream pressure acting on the poppet overcomes spring force.

Ports and positions

The two primary characteristics for selecting a directional-control valve are the number of fluid ports and the number of directional states, or positions, the valve can achieve. Valve ports provide a passageway for fluid (air or hydraulic fluid) to flow to or from other components. The number of positions refers to the number of distinct flow paths a valve can provide.

A 4-port, 3-position spool valve serves as a convenient illustration, Figure 2. One port receives pressurized fluid from the pump, and one routes fluid back to the reservoir (or to the atmosphere or exhaust muffler in a pneumatic systems). The other two ports are generally referred to as work ports and route fluid to or from the actuator. In this case, one work port routes fluid to or from the rod end of the cylinder, the other routes fluid to or from the cap end.

Fig. 2. Schematic shows simple circuit to control cylinder extension and retraction using a 4-port, 3-position spool valve.

The valve represented in Figure 2 can be shifted to any of three discrete positions. As shown, in the neutral position, all ports are blocked, so no fluid will flow. Shifting the valve to the right routes fluid from the pump to the rod end of the cylinder, causing its piston rod to retract. As the piston rod retracts, fluid from the cylinder's cap end flows to the reservoir. Shifting the valve to the left routes fluid from the pump to the cap end of the cylinder, causing the piston rod to extend. As this occurs, fluid from the rod end of the cylinder flows to the reservoir. Returning the valve spool to the center position again blocks all flow. (In reality, a relief valve would be provided between the pump and directional valve. It is omitted here for simplicity.)

Spool-type valves are widely used because they can be shifted to two, three, or more positions for routing fluid between different combinations of inlet and outlet ports. They are used extensively for directional control of actuators because a single valve can produce extension, retraction, and neutral. However, these same functions can be accomplished with digital valves. Figure 3 shows four normally closed (NC) digital valves grouped into a hydraulic integrated circuit to provide the same functionality as the spool valve represented in Figure 2. With all valves in the neutral condition, as shown, fluid flow to and from the pump, reservoir, and actuator is blocked. Energizing valve A routes pressurized fluid to the cap end of the cylinder, causing the rod to extend. Simultaneously energizing valve D routes fluid from the cylinder's rod end to the reservoir. In similar manner, energizing only valves B and C causes the rod to retract and routes fluid from the cylinder's cap end to the reservoir.

Fig. 3. Arranging digital valves into a hydraulic integrated circuit allows them to accomplish the same functions as discrete spool-type valves while retaining the advantages of digital valves.

The valves in Figure 3 are arranged to match the closed-center spool condition of the valve in Figure 2. An open-center condition, Figure 4, could be achieved simply by making all the digital valves normally open (NO) instead of normally closed. Likewise, tandem- and float-center configurations can be accomplished by using NO and NC digital valves.

Fig. 4. Above are common center-spool arrangements for matching neutral-position fluid routes to the application.

These and other common center-position configurations can be quite specialized, depending on the application of the valve. Most manufacturers offer a variety of center-position configurations as standard, off-the shelf items. Although the vast majority of directional-control valves for industrial applications are 2- and 3-position, many valves used in mobile equipment come in 4-position configurations to accommodate special needs.

When specifying the specific type of valve needed for an application, it has become common practice in North America to refer to the number of ports on a valve as the way, such as 2-way, 3-way, or 4-way. However, international standards use the word ports. Thus, what is known as 2-way, 2-position directional valve in the U.S. is called a 2-port, 2-position valve internationally and can be abbreviated 2/2. The number before the slash identifies the number of ports, and the second number refers to the number of positions.

Spool valves

The most common sliding-action valve is the spool-type valve, Figure 5. Fluid is routed to or from the work ports as the spool slides between passages to open and close flow paths, depending on spool position. Spool valves readily adapt to many different spool-shifting schemes, which broadens their use over a wide variety of applications.

Many mobile applications require metering or throttling to enable the operator to slowly or gently accelerate or decelerate a load. In these instances, the spool may be modified with V notches, for example, so that a small displacement of the spool gradually permits increasing or decreasing fluid flow to gradually speed or slow actuator and load movement. This technique is also used in valves for industrial equipment. A beveled or notched edge on the spool is commonly referred to as a soft-shifting feature.

A variation of the single- or multiple-spool valve is the stack valve, Figure 5, in which a number of spool and envelope sections are bolted together between an inlet and outlet section to provide control of multiple flow paths. In addition to providing a central valve location for the machine operator, the valve grouping reduces the number of fluid connections involved and increases ease of sealing. The number of valves that can be stacked in this manner varies from one manufacturer to another.

Fig. 5. This cutaway view of a multiple-spool stack valve shows main directional spools, internal flow passages, and auxiliary valves.

Mounting configurations

Traditional valves are built in a configuration for inline mounting. But this arrangement is labor intensive, requires assembly of multiple components, and is prone to leakage. These factors add to installation cost and can have an even greater impact on maintenance costs. Therefore, most designers choose subbase or manifold mounting to avoid these problems.

In the subbase mounting system, all conducting lines are connected to the subbase and the valve attaches onto the base face with matching port pattern, Figure 6. The static subbase does not wear out, so it does not have to be removed. The valve can be lifted off the subbase after loosening a few screws without disturbing the plumbing. Hydraulic integrated circuits extend the subbase concept even further by mounting several valves onto and into a common manifold, Figure 7.

Removing and replacing pneumatic valves is even easier; many are held securely in place by a latch that can be locked or unlocked in seconds. When centralized control is needed, smart valve manifolds incorporating connections for fieldbus networks and integral programmable logic controllers are available, Figure 8.

Directional valve operators

Valve operators are the parts that apply force to shift a valve's flow-directing elements, such as spools, poppets, and plungers. The sequence, timing, and frequency of valve shifting is a key factor in fluid power system performance. As long as the operator produces enough force to shift the valve, the system designer can select any appropriate operator for the conditions and type of control under which the system will operate.

Operators for directional-control valves are either mechanical, pilot, electrical and electronic, or a combination of these. Different types ofactuators can all be installed on the same basic valve design. A common directional valve often is used that makes provision for mounting a variety of different operators on its body.

With a mechanical operator, a machine element or person applies force on the valve's flow-directing element to move or shift it to another position. Manual operators include levers, palm buttons, push buttons, and pedals. Purely mechanical operators include cams, rollers, levers, springs, stems, and screws. Springs are used in most directional valves to hold the flow-directing element in a neutral position. In 2-position valves, for example, springs hold the non-actuated valve in one position until an actuating force great enough to compress the spring shifts the valve. When the actuating force is removed, the spring returns the valve to its original position. In 3-position valves, two springs hold the non-actuated valve in its center position until an actuating force shifts it. When the actuating force is removed, the springs re-center the valve, leading to the common identification, spring-centered valve. Detents are locks that hold a valve in its last position after the actuating force is removed " until a stronger force is applied to shift the valve to another position. The detents may then hold this new position after the actuating force again is removed.

Mechanical operation is probably the most positive way to control industrial fluid power equipment. If a valve must shift only when a machine element is in a certain position, the equipment can be designed so that the machine element physically shifts the valve through a mechanical operator when the element reaches the correct position. This arrangement virtually eliminates any possibility of false or phantom signals from shifting the valve at the wrong time.

However, mounting mechanically operated valves on a machine requires some special cautions. The valve and actuator may be exposed to a wet or dirty environment that requires special sealing. The actuator will probably be subjected to impact loads, which must be limited to avoid physical damage. Valve alignment with the operating element also is important, so the valve must be mounted accurately and securely for long service life.

Pilot-actuated valves are shifted by pressurized fluid (air or oil) that applies force to a piston that shifts the valve's flow-directing elements. An important advantage of pilot operation is that large shifting forces can be developed without the impact and wear that affects mechanically actuated valves. Pilot-operated valves can be mounted in any convenient or remote location to which pressure fluid can be piped. The absence of sparks and heat buildup makes pilot-actuated valves attractive for applications in flammable or explosive environments.

Electrical or electronic valve operation involves energizing a solenoid. The force generated at the solenoid plunger then shifts the valve's flow-directing element. Solenoid-actuated valves are particularly popular for industrial machines because of the ready availability of electric power in industrial plants. However, mobile equipment makes extensive use of solenoid-operated valves as well. The selection of AC or DC solenoids depends on the form of electrical power available. At one time DC solenoids offered longer service life, but improvements in AC solenoid designs have eliminated that advantage.

There is a practical limit to the force that solenoids can generate. This means they cannot directly shift valves requiring high shifting forces. Furthermore, valves using large solenoids also consume substantial electrical power when valves must remain actuated for long intervals. Heat buildup can also pose problems in these situations. The solution is to use small, low-power solenoids in combination with pilot pressure. The solenoid starts and stops pilot flow, and pilot pressure provides the high force to shift the valve's flow-directing mechanism.

Many valves have combinations of these operators so that the valve can be shifted in response to more than one type of signal. For instance, the solenoid of a 4/3 valve can shift the valve spool in one direction, and a spring would shift it back to the neutral position when the electric signal ceases. Because many valves use more than one type of operator, it is important to determine the role of each. For example, a pilot-solenoid valve may require pilot flow and electrical power to operate. Or it may use either one: solenoid power if an electrical source is available, or pilot operation is the environment must be explosion proof.

Fig. 6. Subbase-mounted valves simplify mounting and replacement of valves because they can be removed and replaced without disturbing system plumbing.

Fig.7. Hydraulic integrated circuits have become popular for both industrial and mobile hydraulic systems because they simplify installation and maintenance, reduce leakage, and can drastically reduce the amount of hose and tubing otherwise needed for inline-mounted valves. They can incorporate screw-in and slip-in cartridge valves, subbase-mounted valves, and other components in a centralized location.

Fig. 8. Smart pneumatic manifold provides centralized electropneumatic control. The self-contained package includes modular valves, PLC, and connectors for DeviceNet or proprietary fieldbus protocols.

Hydraulic spool valve:

In the Operator's Seat

In the previous two sections, you learned how the hydraulics and other pieces of equipment on the hydraulic truck crane work. All of this equipment is controlled by the operator inside the cab, which is located on top of the deck. Crane operators use several control mechanisms to raise and lower the boom, rotate the cab and boom, wind and unwind the winch and control other peripheral equipment.


The crane is operated by hydraulic joysticks and foot pedals.

The 70-ton Link-Belt hydraulic truck crane has two basic types of controls for maneuvering a load:

· Joysticks - There are two joysticks in the cab. One controls left-to-right movement of the boom, and the other controls forward and aft movement.

· Foot pedals - These pedals are responsible for retracting and extending the telescoping sections of the boom. They also control the amount of pressure being generated by the pump.

Joy sticks and foot pedals are connected to hydraulic hoses that connect various hydraulic rams to spool valves. The spool valve is connected to the hydraulic pump via a third hose that is placed between the two hoses that run from the spool valve to the hydraulic ram. When a joystick is pushed in one direction, it causes the valve to shut off one of the hydraulic hoses leading to the ram and open the other. Which way the joystick is pushed determines whether the piston in the hydraulic ram slides in or out.

Your browser does not support JavaScript or it is disabled.

The spool-valve system lets the crane operator control

the hydraulic pistons.

Prior to any lift, the operator enters data into a computer inside the cab, including the weight of the object to be lifted and the height to which it is to be lifted. This computer serves as the operator's backup, warning the operator if the crane is being pushed beyond its capability. Using a binder of charts in the cab, the operator also determines the angle of lift and the radius of the boom. Once all of this is entered, the computer can track the progress of the lift and warn the driver if the crane is nearing its limitations. If the boom is lifted too high for the load amount, a series of lights just above the inside of the front window will begin to light up. These lights are the warning lights for the Load Moment Indicator (LMI).


If the operator tries to lift a load too high, the Load Moment Indicator will light up.

There are at least two other people needed to perform a lift properly, including the oiler and the signalman. The oiler is responsible for making sure that all of the crane's parts are in place and secured prior to any lift. He or she also acts as a spotter during a lift to ensure that the lift is being performed properly. The signalman, as the name suggests, gives hand signals to the operator during the lift to make sure the load is being maneuvered correctly. Click here to see some of the hand signals used during a lift.

Hydraulic truck cranes provide brute strength to move objects, machines and even large animals that would otherwise be very difficult to budge. Using a very simple principle of hydraulics, these machines move thousands of pounds with relative ease, making them an essential component of most construction projects and a great example of the power of basic physics.