TOC Analyzer
Total Organic Carbon (TOC) Analyzer
Lotix Combustion TOC Analyzer
Methods
Standard Method 5310B
EPA 415.1 and 9060A
ASTM D2579
ISO 8245
AOAC 973.47
EN 13639
Key Features
No costly syringe drives or 7-port valves!
Ability to run 0-20,000 ppm without dilution with a single 0.5 mL injection volume virtually eliminating the need for multiple calibration curves
Easy to use software requiring < 1 minute to set up a calibration curve
Simple design ensures virtually any component can be accessed in minutes, and with the furnace located in the front, combustion tube maintenance is a snap
Real-time viewing of analytical data and printing of completed sample reports while instrument is running
Easy scheduling of priority samples
Ability to export to CSV or PDF and import from CSV files
Average run time for triplicate TOC is 13-15 minutes (depending on concentration)
Uses a pressurized 10 L water reservoir to clean the sample pathway, loop and needle before and after each sample without using any positions on the autosampler
Torch TOC Combustion Analyzer
Methods
EPA 415.1, 415.3 and 9060A
Standard Method 5310B
EP 2.2.44, ISO 8245
EN 1484
USP 643 (Chapter 24)
ASTM D2579
prENV 13370
AOAC 973.47
Key Features
Built-in benchmark diagnostic check - including leak check
Ability to program and store furnace temperatures to accommodate various methods
Static Pressure Concentration Technology (patent pending)
Intellidilution feature automatically detects samples that have exceeded the selected calibration range and dilutes it to fall within the selected range
Multiple pre-set application ranges for analytical requirements
Auto-calibration eliminates the need for manual standard preparation
Detection Levels:
Carbon 50ppb to 30,000ppm
Easy access for maintenance of combustion tube
Improved catalyst
Built-in autosampler
Increased throughput with ASM Sparge
Auto-blanking
Mass Flow Controller
Optional vial mixing capabilities
Fusion TOC UV/Persulfate Analyzer
Methods
EPA 415.1- 415.3, 9060A
Standard Method 5310C, ASTM D4779 and D4839
prENV 13370
Cleaning Validation / USP TOC Method <643> / EP 2.2.44 / JP
Key Features
The Fusion Total Organic Carbon (TOC) Analyzer and TekLink™ Software offer solutions for increased sample throughput while improving the reliability of the analysis data. A few of the features that provide increased ease of use are:
Unattended auto-calibration monitoring
Automatic dilution capabilities from stock standards or samples
Intellidilution for automatically diluting a sample back into calibration range.
Automated self-diagnostic tools including leak check
21 CFR 11 functionality - Electronic Records and Electronic Signatures (ERES) including audit trails and user-account management
Exportable reports in user-definable formats including metadata and versioning
Turn-key method development and schedule builder
Mass Flow Controller (MFC) for reduced gas consumption and enhanced flow control