DPX -Disposable Pipette Extraction
The DPX option enables the automation of dispersive solid phase extraction immediately before injection using the MultiPurposeSampler MPS. Using the DPX option, you can enrich and purify analytes from a sample. A full, automated solid phase extraction on a miniaturized scale in a single-use pipette tip can be performed using only small quantities of sample. The system is controlled using the MAESTRO software. Within the software itself, all sample preparation steps can be prepped ahead to save time.
Quickmix
The QuickMix option allows a rapid vertical shaker to be integrated as part of the automatic sample preparation process using the MultiPurposeSampler MPS. Using the QuickMix option, you can even mix poorly miscible 2-phase mixtures, such as water and oil. The system is controlled using the MAESTRO software. Within the software itself, all preparation steps can be prepped ahead to save time.
mVap
The mVAP option allows up to 6 samples to be evaporated in parallel using the MultiPurposeSampler MPS. Evaporation is accelerated by lowering the pressure down to a vacuum and by heating and shaking the samples. These parameters can be adjusted in line with your analytical requirements. The system is controlled using the MAESTRO software. Within the software itself, all preparation steps can be prepped ahead to save time.
Filtration
Complete automation of filtration process using sample preparation functions controlled by GERSTEL MAESTRO software.
Compatible with 4 mm syringe filters or 4 mm – 27 mm disk filters
Can be used as a stand-alone WorkStation or in conjunction with a GC/MS or LC/MS system for injection of the cleaned up sample.
Can be used with other GERSTEL modules such as vortexing, centrifugation or SPE.
Twister SBSE
The Stir Bar Sorptive Extraction
Enables analytes from liquid or gaseous samples to be enriched solvent-free.
Due to the large phase volume, the Twister is very sensitive and is therefore especially suitable when performing trace analytics.
You can simply use the Twister and reuse it many times. The back extraction of the analytes is also possible.
Agitators
The orbital shaker can heat and shake up to 4 samples at the same time. The shaking step is a fixed component of a headspace or SPME run. You can also use the shaking step as part of the automated sample preparation process, however. The system is controlled using the MAESTRO software. Within the software itself, all preparation steps can be prepped ahead to save time.
SPE-Solid Phase Extraction
The SPE 2 option enables the automation of the conventional solid phase extraction using the MultiPurposeSampler MPS. Using the SPE 2 option, you can enrich and purify analytes from a sample.
All steps that form part of the solid phase extraction process can be put together individually, enabling you to adapt the process to your analytical requirements.
The system is controlled using the MAESTRO software. Within the software itself, all sample preparation steps can be prepped ahead to save time.