Radio-Occultation

Storm 2015: 073-079

Model: NEDM

Instrument: Radio-Occultation

FoF2 maps

Top panel shows the critical frequency (FoF2) values obtained by the radio-occultation (RO) measurements of COSMIC-1.

Bottom panel shows the corresponding FoF2 values computed using NEDM model.

y-axis is related to the magnetic latitude of IGRF.

x-axis is related to the day of year.

Storm event main phase starts in the beginning of DOY 076.

Histogram of error and correlation

Left panel shows the histogram of error between NEDM and RO FoF2 measurements of COSMIC-1

y-axis is related to number of occurrences of a specific error value.

x-axis is the FoF2 error.

The mean error (µ) and standard deviation of the error (σ) are shown in the top-right side of the plot.

Right panel shows the correlation (r) of the FoF2 measurements and NEDM values.

hmF2 maps

Top panel shows the critical frequency (FoF2) values obtained by the radio-occultation (RO) measurements of COSMIC-1.

Bottom panel shows the corresponding FoF2 values computed using NEDM model.

y-axis is related to the magnetic latitude of IGRF.

x-axis is related to the day of year.

Storm event main phase starts in the beginning of DOY 076.

Histogram of error and correlation

Left panel shows the histogram of error between NEDM and RO FoF2 measurements of COSMIC-1

y-axis is related to number of occurrences of a specific error value.

x-axis is the FoF2 error.

The mean error (µ) and standard deviation of the error (σ) are shown in the top-right side of the plot.

Right panel shows the correlation (r) of the FoF2 measurements and NEDM values.

Electron density profiles - daytime

Left panel shows the predominant patterns of the electron density profiles measured by radio-occultation techniques using COSMIC-1 data.

Middle panel shows the same, but measured by NEDM.

Right panel shows the predominant pattern of the errors between NEDM and COSMIC-1 values.

y-axis is related to the altitude.

x-axis is related to the Ne values.

The color represents the normalized occurrence of a specific Ne value at a specific height. It can be understand as a normalized 2D histogram.

Electron density profiles - nighttime

Left panel shows the predominant patterns of the electron density profiles measured by radio-occultation techniques using COSMIC-1 data.

Middle panel shows the same, but measured by NEDM.

Right panel shows the predominant pattern of the errors between NEDM and COSMIC-1 values.

y-axis is related to the altitude.

x-axis is related to the Ne values.

The color represents the normalized occurrence of a specific Ne value at a specific height. It can be understand as a normalized 2D histogram.