(a) The general dimensional requirements for each zone district are set forth in Tables 5-10 A, B, C, and D below. Each table addresses a different set of zone districts:
Table A: Rural Zone Districts
Table B: Urban / Suburban Residential Zone Districts
Table C: Affordable Housing Zone Districts
Table D. Business and Special Purpose Zone Districts
(b) Throughout this Land Use Code, references to “Table 5-1” shall be a reference to all of the information contained in the four sub-tables 5-1.A, B, C, and D.
(c) Where two rows in these tables are separated by a dashed line, rather than a solid line, the two rows represent alternative measures of that dimension, the most restrictive of which shall apply.
(d) Each of the four sub-tables 5-1.A, B, C and D contain footnotes that immediately follow each sub-table and should be reviewed in conjunction with the sub-table.
(e) Dimensional requirements for the PUB, I, U and AC/REC-2 zone districts are set foth in Sec. 3-80.
(f) Dimensional requirements for the CD-PUD zone district are set forth in Section 3-70-40.
Code repealed and reenacted (all sections) by Ord. 014-D-2006, 07-05-08; § 5-10-10 – Table 5-1.A (part) amended Ord. 30-06, 10-11-06; Ord. 012-2008, 04-09-08; Ord. 023-07, 08-28-07; Ord. 024-08, 07-23-08; Ord. 019-09, 06-24-09; Ord. 011-11, 08-10-11; Ord. 005-14, 03-12-14); Ord. 037-18, 08-22-18
(Code repealed and reenacted (all sections) by Ord. 014-D-2006, 07-05-06; § 5-10-10 Table-5-1.B (part) amended Ord. 026-06, 09-13-06; Ord. 012-08, 04-09-08; Ord. 024-08, 07-23-08; Ord. 019-09, 06-24-09; Ord. 011-11, 08-10-11; Ord. 029-12, 10-24-12; Ord. 033-12, 11-14-12; Ord. 005-14, 03-12-14)
(Code repealed and reenacted (all sections) by Ord. 014-D-2006, 07-05-08; § 5-10-10 Table-5-1.B (part) amended Ord. 026-06, 09-13-06; Ord. 012-08, 04-09-08; Ord. 024-08, 07-23-08; Ord. 001AB-11, 01-12-11; Ord. 011-11, 08-10-1; Ord.002-13, 01-23-2013; Ord. 005-14, 03-12-14)
(Code repealed and reenacted (all sections) Ord. 014-D-2006, 07-05-08; § 5-10-10 Table-5-1.C (part) amended Ord. 012-08, 04-09-08; Ord. 024-08, 07-23-08; Ord. 005-14, 03-12-14)
NOTES TO TABLE 5-1.C: Dimensional Requirements for Affordable Housing Zone DistrictsABBREVIATIONSDUP = Duplex; MF/S = Multi-Family Studio; MF/1 = Multi-family 1 Bedroom; MF/2 = Multi-family 2 Bedroom; MF/3 = Multi-family 3 Bedroom; MFU = Multi-family with more than 3 Bedrooms; SFD = Single Family DwellingNOTE 1: For lands previously zoned AH2/PUD, AH3/PUD, and AHP-PUD, review and approval of AHP-PUD applications shall be based upon the criteria in Sec. 3-50-80 including but not limited to neighborhood compatibility and adjacent zone district regulations. NOTE 2: As a general guideline, development density may be double that of the underlying zone district. Additional density may be approved in specific cases where it is consistent with the Pitkin County Comprehensive Plan and the development has been designed to avoid or mitigate adverse impacts on surrounding properties. NOTE 3: An additional setback may be required or a lesser setback may be allowed pursuant to Sec. 7-20-80.NOTE 4: The FARs shall be applied to the proposed fathering parcel. Floor area allocations on newly proposed subdivided lots shall be determined as part of the PUD review, but in no case shall they cumulatively exceed the provisions in this Table. Sites may be developed up to eighty-five percent (85%) of the allowed floor area. Up to one hundred percent (100%) of the floor area may be permitted by special review, pursuant to Sec. 2-40-20. NOTE 5: (1) Free market dwelling units = 5,000 square feet; (2) Resident Occupied dwelling units = Maximum allowed by the employee housing guidelines in effect at the time of building permit issuance; (3) Category dwelling units = Must comply with minimum net livable square footage required by housing guidelines -- maximum 250 square foot garage for MF/S and 1-BR units; maximum 500 square foot garage for Other MF units with 2 or more bedrooms; (4) Floor area for the development shall not exceed two times the maximum floor area allowed in the applicable zone district prior to the rezoning.NOTE 6: Development of a micro hydroelectric energy system may be allowed in a setback pursuant to Section 7-20-80(c) and 4-30-50(m).NOTE 7: Stream restoration projects may encroach into this setback pursuant to Sections 7-20-40 and 7-20-80.NOTE 8: All areas mapped within the WOMP Overlay Zone District shall be subject to Section 3-70-50.(Code repealed and reenacted (all sections) Ord. 014-D-2006, 07-05-08; § 5-10-10 Table-5-1.c (part) amended Ord. 012-08; 04-09-08; Ord. 024-08, 07-23-08; Ord. 001 AB-11, 01-12-11; Ord. 005-14, 03-12-14)
Code repealed and reenacted (all sections) by Ord. 014-D-2006, 07-05-08; § 5-10-10 Table-5-1.D (part) amended Ord. 024-08, 07-23-08; Ord. 011-11, 08-10-11; Ord. 005-14, 03-12-14)
NOTES TO TABLE 5-1.D: Dimensional Requirements for Commercial Zone DistrictsABBREVIATIONSM = As approved in Master Plan for P-I zone district; DRM = Dormitory (6-8 persons); DUP = Duplex; HML = Hotel/Motel/Lodge; MF/1L= Multi-family 1 Bedroom Unlimited; MF/ST = Multi-family Studio; MF/1 = Multi-family 1 Bedroom; MF/3 = Multi-family 3 Bedroom; MF/UL = Multi-family with more than 3 bedrooms; OTH = Other; SFD = Single Family DwellingNOTESNOTE 1: 5,000 sq. ft., which shall include any land areas within the Redstone A Lots (as defined in this Land Use Code)NOTE 2: Off-street parking, signs, and lights shall meet the setback requirements for outside uses. Access roads, highway regulatory and directional signs, safety lighting, and safety features shall be allowed between the right-of-way and the setbacks listed. Off street parking and lights don’t need to meet the setback required on collector streets.NOTE 3: An additional setback may be required or a lesser setback may be allowed pursuant to Sec. 7-20-80.NOTE 4: Maximum height principal structures: Twenty-four (24) feet to the top of ridge; Sixteen (16) feet to the top of eave. (dormers excluded). See also Sec. 5-20-60(i) for Building Height calculation methodology.NOTE 5: Maximum height accessory structures: Twenty-one (21) feet to the top of ridge; Twelve (12) feet to the top of eave. (dormers excluded). Accessory structure height is measured from existing grade. See also Sec. 5-20-60(i) for Building height calculation methodology. NOTE 6: (1) Lot with 50-74 ft. frontage = 2,200 square feet; (2) Lot with 75-99 ft. frontage = 2,500 square feet; (3) Lot with 100 ft or larger frontage = 2,800 square feet; (4) A hotel/motel/ lodge/tourist accommodation may apply by special review for a floor area ratio of up to .53. See also Sec. 5-20-70 for Floor Area calculation methodology.NOTE 7: For properties located outside of an urban growth boundary, and zoned T prior to the 5th of July, 2006 future, non-residential structures constructed after the 5th of July, 2006 shall be limited to 15,000 square feet of floor area. Final maximum floor area for residential structures shall be limited to 5,750 sq.ft. of gross floor area.NOTE 8: Development of a micro hydroelectric energy system may be allowed in a setback pursuant to Section 7-20-80(c) and 4-30-50(m).NOTE 9: Stream restoration projects may encroach into this setback pursuant to Sections 7-20-40 and 7-20-80.NOTE: 10: All areas mapped within the WOMP Overlay Zone District Shall be subject to Section 3-70-50.(Code repealed and reenacted (all sections) by Ord. 014-D-2006; § 5-10-10 Table-5-1.D (part) amended Ord. 012-08, 04-09-08; Ord. 024-08, 07-23-08; Ord. 005-14, 03-12-14)
The permitted density of development on lands with steep slopes shall be as follows:
(a) There shall be a reduction in density from that which is allowable in the zone district whenever more than thirty (30) percent of the total land area of a project is encumbered by slopes of forty-five (45) percent and greater. The gross allowable density of the project shall be reduced by one (1) percent for each one (1) percent exceeding thirty (30) percent of land area having slopes of forty-five (45) percent and greater.
(b) The calculation of the formula in subdivision A is as follows: Assuming a three thousand one hundred (3,100) acre parcel of land on which fifty (50) percent of the total land area has slopes greater than forty-five (45) percent, the gross allowable zoned density is three thousand one hundred (3,100) acres divided by thirty (30) (one unit per thirty (30) acres) = one hundred three (103) units allowed. The density reduction is calculated as follows:
(c) An example of the application of the formula to a three thousand one hundred (3,100) acre parcel in RS-30 where the gross zoned density is one hundred three (103) units is given below, assuming different amounts of land with slopes greater than forty-five (45) percent.
TABLE 5-2: Density Reductions for Steep Slopes
Land Area in Excess of 45% Density Reduction Units Substracted Net Units
0-30% 0% 0 103
45 15 15 88
50 20 21 82
60 30 31 72
75 45 46 57
85 55 57 46
95 65 67 36
(d) In order to determine the amount of land area having slopes of forty-five (45) percent and greater, the applicant shall submit a slope analysis using ten (10) foot contoured topography obtained from the Pitkin County Geographic Information Systems (GIS) Department. In the event that ten (10) foot contours do not provide enough detail to adequately determine slope, a certified survey delineating two (2) foot contours may be required at the County Planner’s discretion.
(Code repealed and reenacted (all sections) by Ord. 014-D-2006, 07-05-06; § 5-10-20 (part) amended Ord. 023-07, 08-28-07)