Dryer Fuse and Hi Limit pictures and locations

Kenmore/ Whirlpool

     dryer fuse

    33001762

 Maytag fuse

thermal limit kit

    LA-1053

GE Hotpoint fuse

non-resettable limit

    WE4X800

   dryer duct fuse

   3390719

    more dryer fuses

Left to right:

Kenmore hi limit -279769 (as seen below)

Maytag hi limit -LA1053

Amana high limit - 490P3

Frigidaire fuse- 134120900

 

NOTE:

The kenmore fuse mounts on the dryer blower housing.On

a gas model this fuse when blown will allow the dryer to run

however on an electric model this fuse will kill the dryer.

 

The maytag fuse mounts on the right hand side of the heater.

Note: the 2 fuses that come in the kit are rated for gas or electric dryers.

When this fuse blows the dryer will be dead.

The GE fuse mounts in the rear on the heater element pan.

When this fuse blows the dryer will not run.

Dryer duct fuses are used on various brands of dryers as a back up

they sometimes come in pairs with one mounted on the heater and another near the blower.

Bonus info:

The Kenmore hi limit( small one on left below) will kill the heater element but not kill the machine,

it mounts on top of the heater housing. The bottom limit comes with it,

always replace them both when repairing the dryer. The small one is 300f the big un is

rated for 250 f so the little one goes out you need to replace the big un cause it didn't shutdown.

                FSP* 279769 limit kit for Whirlpool/Kenmore

The Amana fuse mounts on the heater assembly. It kills the heater but not the dryer.

The Frigidaire/Westinghouse/Gibson dryer fuse mounts on the upper right hand

corner of the rear wall. If it blows the whole dryer will not run.

* factory specified part number