sdj-10086

Significance of Width of Keratinized Mucosa on Peri-Implant Tissue Health: A Cross-Sectional Study

*Mohammed T. Fatih, **Faraedon M. Zardawi, **Sarhang S. Gul 

*Kurdistan Board for Medical Specialties, Iraq. 

**Kurdistan Board for Medical Specialties and Department of Periodontics, College of Dentistry, University of Sulaimani, Sulaimani, Iraq. 

Submitted: 02/03/2019; Accepted: 23/04/2019; Published 01/06/2019

DOI: https://doi.org/10.17656/sdj.10086

Abstract

Objective: Impact of the width of keratinized mucosa on peri-implant health is controversial. Thus, the aim of this study is to determine the impact of the width of keratinized mucosa on the health status of the peri-implant tissue.  

Methods: Thirty-nine patients with one hundred fifty-seven dental implants with loading time ranged between 1 to 9 years were recruited. Clinical examinations included plaque index (PI), bleeding on probing (BOP), probing pocket depth (PPD), the width of keratinized mucosa (WKM), buccal mucosal recession (MR) and radiographic bone loss (RBL). Statistical analysis was accomplished with bivariate Pearson correlation test and chi-square test. The result was considered statistically significant when the p-value was  ≤ 0.05. 

Results: The mean PI, BOP, MR and RBL were significantly higher for those dental implants with < 2 mm keratinized mucosa compared to those with more than 2 mm WKM. While there was no significant relation between PPD and WKM, statistically significant association between WKM and PI, BOP and MR were found, whereas, no significant relations were detected between WKM and PPD and RBL.

Conclusions: A significant association between WKM and peri-implant tissue health was found. Dental implants with a sufficient WKM >2mm facilitate better oral hygiene measures and better peri-implant health. The augmentation of mucosal tissue for those dental implants with insufficient WKM can provide better prognosis and may extend the life expectancy of the implant.

                                                                                                                                                                                                                                                                                                                                             

Keywords: Width of keratinized mucosa, Peri-implant health.                                                                                                                                                                                                                                                Full Article - PDF                                                                                                                                                                                                                                        

                                                                                                                                                                                                                                                                                                                                                

References:

1. Chiu YW, Lee SY, Lin YC, Lai YL. Significance of the width of keratinized mucosa on peri-implant health. J Chin Med Assoc. 2015;78(7):389-94. 

2. Karthik K, Sivakumar, Sivaraj, Thangaswamy V. Evaluation of implant success: A review of past and present concepts. J Pharm Bioallied Sci. 2013;5(Suppl 1):S117-9.

3.Ainamo J, Loe H. Anatomical characteristics of gingiva. A clinical and microscopic study of the free and attached gingiva. J Periodontol. 1966;37(1):5-13. 

4. Jansen JA, de Wijn JR, Wolters-Lutgerhorst JM, van Mullem PJ. Ultrastructural study of epithelial cell attachment to implant materials. J Dent Res. 1985;64(6):891-6. 

5. Adibrad M, Shahabuei M, Sahabi M. Significance of the width of keratinized mucosa on the health status of the supporting tissue around implants supporting overdentures. J Oral Implantol. 2009;35(5):232-7. 

6. Stetler KJ, Bissada NF. Significance of the width of keratinized gingiva on the periodontal status of teeth with submarginal restorations. J Periodontol. 1987;58(10):696-700. 

7. Chung DM, Oh TJ, Shotwell JL, Misch CE, Wang HL. Significance of keratinized mucosa in maintenance of dental implants with different surfaces. J Periodontol. 2006;77(8):1410-20. 

8. Lang NP, Loe H. The relationship between the width of keratinized gingiva and gingival health. J Periodontol. 1972;43(10):623-7. 

9. Lindhe J, Berglundh T. The interface between the mucosa and the implant. Periodontol 2000. 1998;17:47-54. 

10. Lindhe J, Berglundh T, Ericsson I, Liljenberg B, Marinello C. Experimental breakdown of periimplant and periodontal tissues. A study in the beagle dog. Clin Oral Implants Res. 1992;3(1):9-16. 

11. Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10(6):387-416. 

12. Wennstrom JL, Bengazi F, Lekholm U. The influence of the masticatory mucosa on the periimplant soft tissue condition. Clin Oral Implants Res. 1994;5(1):1-8. 

13. Boynuegri D, Nemli SK, Kasko YA. Significance of keratinized mucosa around dental implants: a prospective comparative study. Clin Oral Implants Res. 2013;24(8):928-33. 

14. Souza AB, Tormena M, Matarazzo F, Araujo MG. The influence of peri-implant keratinized mucosa on brushing discomfort and peri-implant tissue health. Clin Oral Implants Res. 2016;27(6):650-5. 

15. Pranskunas M, Poskevicius L, Juodzbalys G, Kubilius R, Jimbo R. Influence of Peri-Implant Soft Tissue Condition and Plaque Accumulation on Peri-Implantitis: a Systematic Review. J Oral Maxillofac Res. 2016;7(3):e2. 

16. Schrott AR, Jimenez M, Hwang JW, Fiorellini J, Weber HP. Five-year evaluation of the influence of keratinized mucosa on peri-implant soft-tissue health and stability around implants supporting fullarch mandibular fixed prostheses. Clin Oral Implants Res. 2009;20(10):1170-7. 

17. Mombelli A, van Oosten MA, Schurch E, Jr., Land NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol. 1987;2(4):145-51. 

18. Weber HP, Crohin CC, Fiorellini JP. A 5-year prospective clinical and radiographic study of nonsubmerged dental implants. Clin Oral Implants Res. 2000;11(2):144-53. 

19. Tenenbaum H. A clinical study comparing the width of attached gingiva and the prevalence of gingival recessions. J Clin Periodontol. 1982;9(1):86-92. 

20. Kim BS, Kim YK, Yun PY, Yi YJ, Lee HJ, Kim SG, et al. Evaluation of peri-implant tissue response according to the presence of keratinized mucosa. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;107(3):e24-8. 

21. Lin GH, Chan HL, Wang HL. The significance of keratinized mucosa on implant health: a systematic review. J Periodontol. 2013;84(12):1755-67. 

22. Bouri A, Jr., Bissada N, Al-Zahrani MS, Faddoul F, Nouneh I. Width of keratinized gingiva and the health status of the supporting tissues around dental implants. Int J Oral Maxillofac Implants. 2008;23(2):323-6. 

23.Perussolo J, Souza AB, Matarazzo F, Oliveira RP, Araujo MG. Influence of the keratinized mucosa on the stability of peri-implant tissues and brushing discomfort: A 4-year follow-up study. Clin Oral Implants Res. 2018;29(12):1177-85.

24. Krekeler G, Schilli W, Diemer J. Should the exit of the artificial abutment tooth be positioned in the region of the attached gingiva? Int J Oral Surg. 1985;14(6):504-8. 

25. Zigdon H, Machtei EE. The dimensions of keratinized mucosa around implants affect clinical and immunological parameters. Clin Oral Implants Res. 2008;19(4):387-92. 

26. Mericske-Stern R, Steinlin Schaffner T, Marti P, Geering AH. Peri-implant mucosal aspects of ITI implants supporting overdentures. A five-year longitudinal study. Clin Oral Implants Res. 1994;5(1):9-18. 

27. Gobbato L, Avila-Ortiz G, Sohrabi K, Wang CW, Karimbux N. The effect of keratinized mucosa width on peri-implant health: a systematic review. Int J Oral Maxillofac Implants. 2013;28(6):1536-45. 

28. Bengazi F, Wennstrom JL, Lekholm U. Recession of the soft tissue margin at oral implants. A 2-year longitudinal prospective study. Clin Oral Implants Res. 1996;7(4):303-10. 29. Small PN, Tarnow DP. Gingival recession around implants: a 1-year longitudinal prospective study. Int J Oral Maxillofac Implants. 2000;15(4):527-32. 

30. Cardaropoli G, Lekholm U, Wennstrom JL. Tissue alterations at implant-supported single-tooth replacements: a 1-year prospective clinical study. Clin Oral Implants Res. 2006;17(2):165-71. 

31. Nisapakultorn K, Suphanantachat S, Silkosessak O, Rattanamongkolgul S. Factors affecting soft tissue level around anterior maxillary single-tooth implants. Clin Oral Implants Res. 2010;21(6):66-270. 

32. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986;1(1):11-25. 

33. Block MS, Kent JN. Factors associated with soft- and hard-tissue compromise of endosseous implants. J Oral Maxillofac Surg. 1990;48(11):1153-60. 

34. Roos-Jansaker AM, Renvert H, Lindahl C, Renvert S. Nine- to fourteen-year follow-up of implant treatment. Part III: factors associated with periimplant lesions. J Clin Periodontol. 2006;33(4):296-301. 

35. Monje A, Blasi G. Significance of keratinized mucosa/gingiva on peri-implant and adjacent periodontal conditions in erratic maintenance compliers. J Periodontol. 2018. 

36. Romanos G, Grizas E, Nentwig GH. Association of Keratinized Mucosa and Periimplant Soft Tissue Stability Around Implants With Platform Switching. Implant Dent. 2015;24(4):422-6. 

 

 

 © The Authors, published by University of Sulaimani, College of Dentistry

This work is licensed under a Creative Commons Attribution 4.0 International License.