Output and Channel Setup
The timer setup was as per the setup for the Door Bell. While the Door Bell setup was closing a 230v circuit for a 230v transformer and completed on a MAXinBOX 16 Plus and in this case we were just closing the relay, the settings on the Output channel and Timer Parameter settings were almost identical in both cases. I set the 'On' duration to be 1s within the Timer and that worked fine.
A pre-existing range of Group Addresses were provided in a template from the integrator - shown in image below. I only needed to link the Group Object to a single Group Address as the plan was to use an IP interface to open the door from an application program. For testing purposes I added an additional control from a TMD button - which is also shown in the image below. However this was to be deleted once function was confirmed.