AC Wiring Procedure
Revised 2020-01-13 by Rohan Tuli to include ANSI wiring standard.
Follow this procedure when using an AC powered device which requires a custom power cable with exposed contacts, such as the 48V Power Supply or Control Box Lower Board.
Note: Always have someone double check your wiring. It’s better for it to take longer than for you to become part of the circuit.
Obtain a power distribution unit (PDU) with an easily accessible shut off switch. This can be the power strip with the locking power switch.
Plug the PDU into a wall outlet and ensure that it is in the OFF position.
Connected the exposed ends of the power cable to the AC device being used. The ISO wiring standard is:
BROWN - Live
BLUE - Neutral
GREEN - Earth
The ANSI wiring standard is:
BLACK - Live
WHITE - Neutral
GREEN - Earth
Warning: Do not attempt to connect to bullet crimps to a screw terminal designed for spade/ring crimps. Do not attempt to insert spade/ring crimps into a terminal block designed for bare wire or bullet crimps.
Install a safety cover over the connection between the AC device and power cable to prevent accidental contact. Some devices have a flip-down plastic cover. Other devices may require electrical tape.
Ensuring that the PDU is still in the OFF position, plug the non-device end of the power cable into the PDU.
Turn the PDU ON. Ensure that the OFF button on the PDU is within reach while using the AC device.