Peak shape

J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “Peak dispersion in gradient elution: An insight from the plate model”. Journal of Chromatography A 1613, 460670 (2020).

R. Burgos-Gil, E. Peris-García, M.J. Ruiz-Ángel, J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “Protocol to compare column performance applied to hydrophilic interaction liquid chromatography”. Microchemical Journal 149, 103973 (2019).

T. Álvarez-Segura, E. Cabo-Calvet, J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “Study of the efficiency using gradient elution based on Van Deemter plots”. Journal of Chromatography 1584, 126–13413 (2019).

J.A. Navarro-Huerta, J.R. Torres-Lapasió, M.C. García-Álvarez-Coque, “Estimation of peak capacity based on peak simulation”. Journal of Chromatography A 1574, 101–113 (2018).

T. Álvarez-Segura, M.D. Peris-Díaz, M.C. García-Álvarez-Coque, J.J. Baeza-Baeza, ”New approaches to evaluate the dispersion parameters in liquid chromatography based on the information obtained from a set of compounds”. Current Chromatography 4, 156–166 (2017).

J.J. Baeza-Baeza, M.C. García-Álvarez-Coque,“Characterization of chromatographic peaks using the linearly modified Gaussian (LMG) model. Comparison with the bi-Gaussian and the Foley and Dorsey approaches". Journal of Chromatography  A 1515, 129–137 (2017).

S. Carda-Broch, M.C. García-Álvarez-Coque, M.J. Ruiz-Ángel, ”Extent of the influence of phosphate buffer and ionic liquids on the reduction of the silanol effect in a C18 stationary phase”. Journal of Chromatography A 1559, 112–117 (2018).

J.R. Torres-Lapasió, J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “Modeling of peak shape and asymmetry”. Chemometrics in Chromatography, Chromatographic Science Series (edited by Łukasz Komsta, Yvan Vander Heyden, Joseph Sherma), Vol. 111, Chapter 12 (pp. 217–238). Taylor and Francis, Boca Raton, FL (2018). ISBN: 978-1-4987-7253-2.

S. Calabuig-Hernández, M.C. García-Álvarez-Coque, M.J. Ruiz-Ángel, “Performance of amines as silanol suppressors in reversed-phase liquid chromatography”. Journal of Chromatography A 1465, 98–106 (2016).

J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “General solution of the extended plate model including diffusion, slow transfer kinetics and extra-column effects for isocratic chromatographic elution”. Separations (Open access) 3, 11, 1–24 (2016).

M.J. Ruiz-Ángel, S. Pous-Torres, S. Carda-Broch, M.C. García-Álvarez-Coque, “Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases”. Journal of Chromatography A 1344, 76–82 (2014).

E. Cabo-Calvet, C. Ortiz-Bolsico J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “Description of the retention and peak profile for Chromolith columns in isocratic and gradient elution using mobile phase composition and flow rate as factors”. Chromatography (Open access) 1, 194–210 (2014).

S. Pous-Torres, J.R. Torres-Lapasió, M.C. García-Álvarez-Coque, “Comparison of the performance of Chromolith Performance RP-18e, 1.8μm Zorbax Eclipse XDB-C18 and XTerra MS C18, based on modelling approaches”. Analytical and Bioanalytical Chemistry 405, 2219–2231 (2013).

J.J. Baeza-Baeza, M.J. Ruiz-Ángel, S. Carda-Broch, M.C. García-Álvarez-Coque, “Half-width plots, a simple tool to predict peak shape, reveal column kinetics and characterise chromatographic columns in liquid chromatography: State of the art and new results”. Journal of Chromatography A 1314, 142–153 (2013).

J.J. Baeza-Baeza, C. Ortiz-Bolsico, M.C. García-Álvarez-Coque, “New approaches based on modified Gaussian models for describing chromatographic peaks”. Analytica Chimica Acta 758, 36–44 (2013).

M.J. Ruiz-Ángel, S. Carda-Broch, M.C. García-Álvarez-Coque, “Chromatographic efficiency in micellar liquid chromatography: should it be still a topic of concern?”. Separation and Purification Reviews 42, 1–27 (2013).

J.J. Baeza-Baeza, C. Ortiz-Bolsico, J.R. Torres-Lapasió, M.C. García-Álvarez-Coque, “Approaches to model the retention and peak profile in linear gradient liquid chromatography”. Journal of Chromatography A 1284, 28–35 (2013).

J.J. Baez-Baeza, Y. Dávila, J.J. Fernández Navarro, M.C. García-Álvarez-Coque, “Measurement of the elution strength and peak shape enhancement at increasing modifier concentration and temperature in RPLC”. Analytical and Bioanalytical Chemistry 404, 2973–2984 (2012).

J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “A theoretical plate model accounting for slow kinetics in chromatographic elution”. Journal of Chromatography A 1218, 5166–5174 (2011).

J.J. Baeza-Baeza, J.R. Torres-Lapasió, M.C. García-Álvarez-Coque, “Approaches to estimate the time and height at the peak maximum in liquid chromatography based on a modified Gaussian model”. Journal of Chromatography A 1218, 1385–1392 (2011).

J.J. Baeza-Baeza, S. Pous-Torres, J.R. Torres-Lapasió, M.C. García-Álvarez-Coque, “Approaches to characterise chromatographic column performance based on global parameters accounting for peak broadening and skewness”. Journal of Chromatography A 1217, 2147–2157 (2010).

A. Cantó–Mirapeix, J.M. Herrero–Martínez, J.J. Baeza-Baeza, E.F. Simó-Alfonso, “Study of peak shape and efficiency in butyl acrylate-based monolithic columns for capillary electrochromatography”. Journal of Chromatography A 1216, 6831–6837 (2009).

S. Pous-Torres, J.J. Baeza-Baeza, J.R. Torres-Lapasió, M.C. García-Álvarez-Coque, “Peak capacity estimation in isocratic elution”. Journal of Chromatography A 1205, 78–89 (2008).

J.J. Baeza-Baeza, M.J. Ruiz-Ángel, M.C. García-Álvarez-Coque, “Prediction of peak shape in hydro‑organic and micellar-organic liquid chromatography as a function of mobile phase composition”. Journal of Chromatography A 1163, 119–127 (2007).

M.C. García-Álvarez-Coque, E.F. Simó-Alfonso, J.M. Sanchis-Mallols, J.J. Baeza-Baeza, “A new mathematical function for describing electrophoretic peaks”. Electrophoresis 26, 2076–2085 (2005).

G. Vivó-Truyols, J.R. Torres-Lapasió, A.M. van Nederkassel, Y. vander Heyden, D.L. Massart, “Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals. Part II: Peak model and deconvolution algorithms”. Journal of Chromatography A 1096, 146–155 (2005).

G. Vivó-Truyols, J.R. Torres-Lapasió, A.M. van Nederkassel, Y. vander Heyden, D.L. Massart, “Automatic program for peak detection and deconvolution of multi-overlapped chromatographic signals. Part I: Peak detection”. Journal of Chromatography A 1096, 133–145 (2005).

J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “Prediction of peak shape as a function of retention in reversed-phase liquid chromatography”. Journal of Chromatography A 1022, 17–24 (2004).

G. Vivó-Truyols, J.R. Torres-Lapasió, R.D. Caballero, M.C. García-Álvarez-Coque, “Peak deconvolution in one-dimensional chromatography using a two-way data approach”. Journal of Chromatography A 958, 35–49 (2002).

R.D. Caballero, M.C. García-Álvarez-Coque, J.J. Baeza-Baeza, “Parabolic-Lorentzian modified Gaussian model for describing and deconvolving chromatographic peaks”. Journal of Chromatography A 954, 59–76 (2002).

G. Vivó-Truyols, J.R. Torres-Lapasió, A. Garrido-Frenich, M.C. García-Álvarez-Coque, “A hybrid genetic algorithm with local search. II. Continuous variables: Multibatch peak deconvolution”. Chemometrics and Intelligent Laboratory Systems 59, 107–120 (2001).

J.R. Torres-Lapasió, J.J. Baeza-Baeza, M.C. García-Álvarez-Coque, “A model for the description, simulation and deconvolution of skewed chromatographic peaks”. Analytical Chemistry 69, 3822–3831 (1997).