Gecko Spa Packs for Hydropool Hot Tubs must be configured to the proper low level (LL) setting after replacing the spa pack. To find the correct LL setting for your tub, see the below table.
Gecko Spa Packs for Hydropool Hot Tubs must be configured to the proper low level (LL) setting after replacing the spa pack. To find the correct LL setting for your tub, see the below table.
Self-Cleaning One Pump – LL4 (Sometimes LL34 if problems persist)
(395 gold, 495 gold, 570 gold, 670 gold)
Self-Cleaning Two Pump – LL2 (Sometimes LL32 if problems persist)
(670 platinum, 720/770 platinum)
Serenity One Pump – LL9 (LL5 in YE3)
(4000, 5000, 220V SE5L, 4500, 5900)
Serenity Two Pump – LL11 (LL7 in YE3)
(6000, 7000, 6800)
AquaSport Swimspa - LL19 (YE5)
Turn on breaker
Check keypad immediately
Use temperature key to choose ‘LL __’ setting
Use light button to select
Tub will do a self check of systems
Press sprocket to get to menu
Select electrical configuration
Hold confirm
Then adjust low level config with proper LL
Accept the number by selecting low level config again
Hold down P1 for 30 seconds and just with arrow up/down and accept with hitting the filter key twice.
To configure press and hold jet button for 45 seconds,
Use temperature keys to select LL _
Press light button to accept new LL setting.