F.10.2.1 The Floor or Bottom must be made from one of the three:
a. Steel 1.25 mm minimum thickness
b. Aluminum 3.2 mm minimum thickness
c. Equivalent Alternate / Composite materials ( F.4.1, F.4.3 )
F.10.2.2 Vertical Walls, Covers and Lids must be made from one of the three:
a. Steel 0.9 mm minimum thickness
b. Aluminum 2.3 mm minimum thickness
c. Equivalent Alternate / Composite materials ( F.4.1, F.4.3 )
F.10.2.3 The accepted methods of joining walls to walls and walls to floor are:
a. Welding
Welds may be continuous or interrupted
If interrupted, the weld/space ratio must be 1:1 or greater
All weld lengths must be greater than 25 mm
b. Fasteners
Combined strength of the fasteners must be Equivalent to the strength of the welded joint (F.10.2.3.a above)
c. Bonding
Bonding must meet F.5.5
Strength of the bonded joint must be Equivalent to the strength of the welded joint ( F.10.2.3.a above )
Bonds must run the entire length of the joint
F.10.2.4 Covers and Lids must be attached within amiimum of one fastener for each external vertical wall per section.
Explanation