Full-scale Completion Testing (FCT)
Full-Scale Completion Testing (FCT)
A concentric radial cell that accommodates a cylindrical sand control device at the center of the cell.
Injection in this facility follows a radial geometry which is expected for actual producer wells.
Two Triplex metering pumps for oil and brine injection (Max 21 lit/hr)
Stresses provided by Bellofram Diaphragm using air pressure
Pressure transducers at different radial distances
The test cell can rotate 180°, and tests can be conducted at different positions
Larger sand control device (SCD) area, larger fluid volumes, superior resemblance of reservoir conditions
Related Publications:
1. Haftani, M., Kotb, O., Nguyen, P.H., Wang, C., Salimi, M., Nouri, A. (2020). A Novel Sand Control Testing Facility to Evaluate the Impact of Radial Flow Regime on Screen Performance and its Verification. Journal of Petroleum Science and Engineering. 195: 107903.