Arinst VR 23-6200 Portable VNA vector network analyzer
Arinst VR 23-6200 Portable VNA vector network analyzer
VNA ARINST VR 23-6200 is made in a durable aluminum casing in the form of mobile autonomous instrument and is primarily intended to work directly on the object, as with low weight and compact dimensions has a low energy consumption. The analyzer will be especially useful to companies working in the field of telecommunications, engaged in the installation and maintenance of antennas, in the amplification of cellular communication, etc. With it, service centers and repair crews can carry out RF analysis cable and antenna when carrying out commissioning or repair work. In addition, the device is ideal for workshops, radio amateurs, educational institutions and laboratories.
The device has a 3.2" color resistive screen to display the measurement results and control the device.
For example, you can use the instrument to do the following:
To perform impedance matching using the Smith chart
To measure the standing wave ratio
To measure the attenuation in the cable
To measure the distance to fault or irregularity in the cable
Advantages of vector network analyzer ARINST VR 23-6200 MHz
color touch screen with a diagonal of 3.2 inches allows for quick configuration of the scan parameters and display of measurement results
wide operating frequency range: 23 to 6200 MHz
high scan rate of 1000 points/s
high precision of measurement: 0.25 dB and 1.5° over the entire frequency range
the ability to display up to four independent markers on all charts, allowing an accurate assessment of the measured parameter
display almost all possible interpretations of the reflection coefficient
the ability to measure the distance to fault and loss in the cable
small weight and dimensions: 400 grams with "pocket" dimensions 155×81×27 mm
built-in battery provides up to 2 hours of battery life
ability to power the device from a tablet or smartphone via USB OTG cable: not in time discharged battery will not stop the workflow
SPECIFICATIONS ARINST VR 23-6200 MHz
1 The measurement is performed after warming up the device for at least five minutes with a full (short, open, load) single-port calibration. The change in ambient temperature from the time of calibration to the time of measurement shall not exceed ±3 °C.
2 Where C is the speed of light m/s; VF is the speed factor (the ratio of the speed of propagation of the electromagnetic wave in the cable to the speed of propagation of the electromagnetic wave in vacuum), takes a value depending on the cable from 0.1 to 1; S is the scanning frequency range in the frequency task (Hz).
3 Depends on the amount of attenuation in the cable and is the limit of the display.
4 At ambient temperature plus 20±5°C after full charge.