Modeling anchors in TEKLA
BOLT COMMENT:
VIPER XTREM / drill Ø24 / depth 170mm / L=250mm
chemical glue / drilling diameter / drilling depth / length of anchor
mechanical anchor name / drilling diameter / drilling depth / length of anchor
BOLT COMMENT Alternative :
Bolt comment 1: HILTI HIT-HY 200-A + HIT-Z / L=250mm --> Bolt list / Anchor list / GA drawing
Bolt comment 2: drill Ø24 / depth 170mm --> GA drawing / Anchor plan
chemical glue / drilling diameter / drilling depth / length of anchor
mechanical anchor name / drilling diameter / drilling depth / length of anchor
anchor mold
holes in the anchor mold +4mm
For anchors M12 - M20 --> 30mm grouting
For anchors M24 - M30 --> 40mm grouting
For anchors M33 - ** --> 50mm grouting
etc.
The main purpose is to have ~15mm leveling tolerance.
Grouting - Height on NUT = 15mm
Bolts M10 to M24 --> +2mm
From M27 --> +3mm
Anchors --> +4mm
Bolt standard: 10642
head washer turned off
model
GA drawing
Bolt list
Use Treated rod and Bolt (draadstang)
In bolt comment give the correct specification of the anchor
Use @dds boutenlijst.txt to get the bolt comment on the bolt list
Drilling hole is the same diameter as the anchor diameter.
Drilling hole is 2mm larger than the anchor diameter.
For mechanical or chemical anchors always have leveling nut.
Leveling nut can be added bolted to the treated rod in order to avoid double holes on the base plate.
For hanging anchors and anchors to wall don't use leveling nut.