Overview of Status of Analysis, Design, Fabrication, Tests, etc.
Heater machining successful
Accomplishments from Previous Week
Physical system
Heater machining successful
Electronics
Pump test successful (3550 RPM at no load)
Connectors for valves done
Goals for Next Week (list names after each item). Use specific and measurable objectives.
Purchase pressure sensors (May)
Install RTD (all)
Purchase LN2 (all)
Connect all parts (all)
Test Leakage of entire system (all)
Cycle system with CDA (all)
Sponsor Comments from Last Meeting and Actions Taken to Address these Comments (indicate date of comments and if via email or in person)
Pressure sensors with -40C should be OK (await final confirmation)
use T junction and copper coil to warm up gas before reaching sensor
LN2 Dewar has pressure relief valve for hose (ask for spec sheet from Airgas)
Control the heating plate to some reference temperature to achieve inlet gas temp of -150C
Instructor Comments from Last Meeting and Actions Taken to Address these Comments (indicate date of comments and if via email or in person)
Control heating plate temperature instead of gas temperature
More work on report
Comments from Other Students in the Class (indicate date of comments and if via email or in person)
None
Risks and Areas of Concern
Mounting RTD on heating plate
Somewhere not too close to heating rod
Current thought: instead of middle of plate, mount two at each end of plate and take average
Resources or Information Required but not Available
None
Schedule
Describe upcoming milestone
Update Gantt chart.
Budget (list amount spent and amount remaining)
Spent: $1,772.51
Remaining: $1,427.49
Progress on Report and Webpage