Facility
Conducted and Radiated EMI Measurement Systems
- Medium voltage Common-Mode EMI test bed (300kVA, 1.2kV input)
- Line Stabilization Network, LI-3100C, (676V/480Vac, 10 kHz - 400 Mhz, 100 A, 5 uH)
- Custom-designed Medium Voltage Line Stabilization Network (1.5 kV, 40 MHz)
- Near Field Probe, Frequency Range: 30MHz to 3GHz; RF adapter kit
- Combilog antenna, AC 220 (2 GHz)
- Various radiated EMI testing devices
Reliability Analysis Systems
- LCR meters; Bode 100 vector network analyzer (LCR meter); Transient Limiter
- Hioki IM7581-01 LCR meter (100kHz-300Mhz)
- 150L Lab Companion Temperature & Humidity Chamber
- Agilent 1456b semiconductor parameter analyzer, high voltage supply, c/v curve tracer
Data Acquisition Systems
- NI Data acquisition system
- High voltage differential probes (up to 100 MHz and 7 kV)
- Wideband Pearson current monitor 6595 (20A~1000Am, 150 MHz, and 50 Ohm)
- Wideband Pearson current monitor 2877 (200 MHz)
- 1.5 GHz real-time spectrum analyzer with vector network analysis
Motor/Drive Power Converter Systems
- Power Electronics Building Blocks
- Multiphase motor prototypes; ultra-high-speed (half million RPM) electric machine prototypes
- SiC/GaN inverters
Power Supply and Loading Systems
- 800V, 36 kW bi-direction power supply to emulate various renewable energy and vehicle power train
- 6kV, 10 kW DC power supply (Magna)
- 2kV, 20 kW DC power supply (Magna)
- 500V, 10 kW DC power supply (Magna)
- Variable frequency and voltage AC power supply (0~300V) (Chroma)
- Digital load (2.4 kW and 500V)
- High power passive loads
- 3kW custom dynamo
Software
- Various power electronics, electric machine, and filter design, control, and simulation software
Hardware in loop simulation
- dSpace microbox