Hier findest du eine Übersicht über die gängisten Scripte. Sollte dein Zähler nicht dabei sein findest du weitere Scripte auf der Tasmota Seite
>D
scnt=0
res=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 3
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 20
res=sml(1 1 "063035300D0A")
case 23
res=sml(1 0 9600)
case 60
scnt=0
ends
>M 1
+1,3,o,16,9600,12EC3,1
1,1.8.0*00(@1,Verbrauch,kWh,E_in,2
1,1.8.1*00(@1), Verbrauch HT,kWh,E_inHT,2
1,1.8.2*00(@1), Verbrauch NT,kWh,E_inNT,2
1,2.8.0*00(@1,Einspeisung,kWh,E_out,2
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,APOX,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h-------
1,770701001f0700ff@1,Current L1,A,Curr_p1,3
1,77070100330700ff@1,Current L2,A,Curr_p2,3
1,77070100470700ff@1,Current L3,A,Curr_p3,3
1,=h-------
1,77070100200700ff@1,Voltage L1,V,Volt_p1,3
1,77070100340700ff@1,Voltage L2,V,Volt_p2,3
1,77070100480700ff@1,Voltage L3,V,Volt_p3,3
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,LEPUS,1
1,77070100010800ff@1000,Verbrauch,Kwh,E_in,3
1,77070100020800ff@1000,Einspeisung,Kwh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,power,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,Norax,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,77070100200700ff@1,Voltage L1,V,Volt_p1,1
1,77070100340700ff@1,Voltage L2,V,Volt_p2,1
1,77070100480700ff@1,Voltage L3,V,Volt_p3,1
1,770701001f0700ff@1,Amperage L1,A,Amperage_p1,1
1,77070100330700ff@1,Amperage L2,A,Amperage_p2,1
1,77070100470700ff@1,Amperage L3,A,Amperage_p3,1
1,77070100510704ff@1,Phaseangle I-L1/U-L1,deg,phase_angle_p1,1
1,7707010051070fff@1,Phaseangle I-L2/I-L2,deg,phase_angle_p2,1
1,7707010051071aff@1,Phaseangle I-L3/I-L3,deg,phase_angle_p3,1
1,770701000e0700ff@1,Frequency,Hz,frequency,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,PICUS,1
1,77070100010800ff@1000,Verbrauch,Kwh,E_in,3
1,77070100020800ff@1000,Einspeisung,Kwh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,power,0
#
>D
scnt=0
res=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 3
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 20
res=sml(1 1 "063035300D0A")
case 23
res=sml(1 0 9600)
case 60
scnt=0
ends
>M 1
+1,3,o,16,9600,Corax,1
1,0.9.1(@1),Time,,0_9_1,0
1,0.9.2(@1),Date,,0_9_1,0
1,1.7.0(@1),Inst Power,kWh,E_in,2
1,=h ---- Reactive Energy Import ----
1,3.8.0(@1,Total Energy,kvarh,nrg_reac_imp,3
1,3.8.1(@1,T1 Energy,kvarh,t1_reac_imp,3
1,3.8.2(@1,T2 Energy,kvarh,t2_reac_imp,3
1,3.8.3(@1,T3 Energy,kvarh,t3_reac_imp,3
1,3.8.4(@1,T4 Energy,kvarh,t4_reac_imp,3
1,3.2.0(@1,Commulative Energy,kvarh,comm_reac_imp,3
1,3.6.0(@1,Q+ Max Demand,kvarh,dem_reac_imp,3
1,=h ---- Reactive Energy Export ----
1,4.8.0(@1,Total Energy,kvarh,nrg_reac_exp,3
1,4.8.1(@1,T1 Energy,kvarh,t1_reac_exp,3
1,4.8.2(@1,T2 Energy,kvarh,t2_reac_exp,3
1,4.8.3(@1,T3 Energy,kvarh,t3_reac_exp,3
1,4.8.4(@1,T4 Energy,kvarh,t4_reac_exp,3
1,4.2.0(@1,Commulative Energy,kvarh,comm_reac_exp,3
1,4.6.0(@1,Q- Max Demand,kvarh,dem_reac_exp,3
1,=h ---- Active Energy ----
1,15.8.0*01(@1,Abs Energy,kWh,a_plus,2
1,15.8.1*01(@1,T1 Abs Energy,kWh,a1_plus,2
1,15.8.2*01(@1,T2 Abs Energy,kWh,a2_plus,2
1,15.8.3*01(@1,T3 Abs Energy,kWh,a3_plus,2
1,15.8.4*01(@1,T4 Abs Energy,kWh,a4_plus,2
1,15.6.0*01(@1, Abs Total,kWh,atot_plus,2
1,=h ----
1,32.7.0(@1,L1 Voltage,V,volts_l1,1
1,31.7.0(@1,L1 Current,A,amp_l1,1
1,52.7.0(@1,L2 Voltage,V,volts_l2,1
1,51.7.0(@1,L2 Voltage,A,amp_l2,1
1,72.7.0(@1,L3 Voltage,V,volts_l3,1
1,71.7.0(@1,L3 Current,A,amp_l3,1
#
>D
scnt=0
res=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 3
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 20
res=sml(1 1 "063035300D0A")
case 23
res=sml(1 0 9600)
case 60
scnt=0
ends
>M 1
+1,3,o,16,9600,BMX,1
1,1.8.0(@1,Verbrauch,kWh,E_in,3
1,2.8.0(@1,Einspeisung,kWh,E_out,3
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,GS303,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,7707010060320101@#,Service ID,,Meter_id,0
#
//Achtung im Zähler Menü auf dss umstellen
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,DZG,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,77070100600100ff@#,Meter Id,,MeterId,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,DWS7410,1
1,=so2,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,7707010060320101@#,SID,,meter_id,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,0,9600,M60,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,77070100240700ff@1,Watt_L1,W,power_L1,0
1,77070100380700ff@1,Watt_L2,W,power_L2,0
1,770701004c0700ff@1,Watt_L3,W,power_L3,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,Q3A,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,77070100240700ff@1,Leistung_L1,W,Watt_L1,0
1,77070100380700ff@1,Leistung_L2,W,Watt_L2,0
1,770701004c0700ff@1,Leistung_L3,W,Watt_L3,0
1,77070100200700ff@1,Spannung_L1,V,Volt_L1,1
1,77070100340700ff@1,Spannung_L2,V,Volt_L2,1
1,77070100480700ff@1,Spannung_L3,V,Volt_L3,1
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,Q3B,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100010801ff@1000,Verbrauch HT,kWh,E_inHT,3
1,77070100010802ff@1000,Verbrauch NT,kWh,E_inNT,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100010700ff@1,akt. Leistung,W,Power,0
1,77070100150700FF@1,Leistung_L1,W,Watt_L1,0
1,77070100290700FF@1,Leistung_L2,W,Watt_L2,0
1,770701003D0700FF@1,Leistung_L3,W,Watt_L3,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,Q3C,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100010801ff@1000,Verbrauch HT,kWh,E_inHT,3
1,77070100010802ff@1000,Verbrauch NT,kWh,E_inNT,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,77070100150700FF@1,Leistung_L1,W,Watt_L1,0
1,77070100290700FF@1,Leistung_L2,W,Watt_L2,0
1,770701003D0700FF@1,Leistung_L3,W,Watt_L3,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,o,16,9600,Q3D,1
1,1-0:1.7.0*255(@1,akt. Leistung,W,Power,0
1,1-0:1.8.0*255(@1,Verbrauch,kWh,E_in,3
1,1-0:2.8.0*255(@1,Einspeisung,kWh,E_out,3
1,1-0:21.7.0*255(@1,Leistung_L1,W,Watt_L1,0
1,1-0:41.7.0*255(@1,Leistung_L2,W,Watt_L2,0
1,1-0:61.7.0*255(@1,Leistung_L3,W,Watt_L3,0
1,0-0:96.1.255*255(@#),Seriennummer,,serial,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,Q1A,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,77070100240700ff@1,Leistung_L1,W,Watt_L1,0
1,77070100380700ff@1,Leistung_L2,W,Watt_L2,0
1,770701004c0700ff@1,Leistung_L3,W,Watt_L3,0
1,77070100200700ff@1,Spannung_L1,V,Volt_L1,1
1,77070100340700ff@1,Spannung_L2,V,Volt_L2,1
1,77070100480700ff@1,Spannung_L3,V,Volt_L3,1
#
>D
>B
=>sensor53 r
>M 1
+1,3,o,16,9600,eBZ,1
1,1-0:1.8.0*255(@1,Verbrauch,kWh,E_in,3
1,1-0:2.8.0*255(@1,Einspeisung,kWh,E_out,3
1,1-0:16.7.0*255(@1,akt. Leistung,W,Power,0
1,1-0:36.7.0*255(@1,Leistung L1,W,36_7_0,0
1,1-0:56.7.0*255(@1,Leistung L2,W,56_7_0,0
1,1-0:76.7.0*255(@1,Leistung L3,W,76_7_0,0
1,1-0:32.7.0*255(@1,Spannung L1,V,32_7_0,1
1,1-0:52.7.0*255(@1,Spannung L2,V,52_7_0,1
1,1-0:72.7.0*255(@1,Spannung L3,V,72_7_0,1
1,1-0:96.1.0*255(@#),Identifikation,,96_1_0,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,eBZ,1
1,77070100010800ff@1000,Verb.o.PIN,kWh,E_inoP,3
1,77070100020800ff@1000,Einsp.o.PIN,kWh,E_outoP,3
1,=h--------------
1,77070100010800ff@100000000,Verbrauch,kWh,E_in,3
1,77070100020800ff@100000000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100240700FF@1,Leistung L1,W,36_7_0,0
1,77070100380700FF@1,Leistung L2,W,56_7_0,0
1,770701004C0700FF@1,Leistung L3,W,76_7_0,0
1,77070100200700FF@1,Spannung L1,V,32_7_0,1
1,77070100340700FF@1,Spannung L2,V,52_7_0,1
1,77070100480700FF@1,Spannung L3,V,72_7_0,1
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,eBZ,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100240700ff@1,Power L1,W,P_L1,0
1,77070100380700ff@1,Power L2,W,P_L2,0
1,770701004C0700ff@1,Power L3,W,P_L3,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,eBZD,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,ED300L,1
1,=so1,00010800,63,5,63,5,000f0700
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,eHZ,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,770701000f0700ff@1,akt. Leistung2,W,Power2,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,EMH,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
#
>D
scnt=0
res=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 3
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 20
res=sml(1 1 "063035300D0A")
case 23
res=sml(1 0 9600)
case 60
scnt=0
ends
>M 1
+1,3,o,16,9600,AS1440,1
1,1.7.0(@0.001,Power In,W,power_in,0
1,1.8.1(@1,Total In,kWh,Total_in,3
1,2.7.0(@0.001,Power Out,W,power_out,0
1,2.8.1(@1,Total Out,kWh,Total_out,3
1,=h--
1,1-1:1.8.1(@1,Total In HT,kWh,E_inHT,3
1,1-1:1.8.2(@1,Total In NT,kWh,E_inNT,3
1,1-1:2.8.1(@1,Total Out HT,kWh,E_outHT,3
1,1-1:2.8.2(@1,Total Out NT,kWh,E_outNT,3
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,AS2020,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100600100ff@#,Server-ID,,Wert,0
#
>D
scnt=0
res=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 3
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 20
res=sml(1 1 "063035300D0A")
case 23
res=sml(1 0 9600)
case 60
scnt=0
ends
>M 1
+1,3,o,16,9600,AS3500,1
1,1-1:1.8.0(@1,Verbrauch,kWh,E_in,3
1,1-1:1.7.0(@0.001,akt. Leistung,W,Power,3
1,1-1:21.7.0(@0.001,Leistung L1,W,Power_L1,3
1,1-1:41.7.0(@0.001,Leistung L2,W,Power_L2,3
1,1-1:61.7.0(@0.001,Leistung L3,W,Power_L3,3
1,1-1:0.0.0(@1,SN,1,SN,0
#
>D
res=0
scnt=0
>B
->sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 50
scnt=0
ends
>M 1
+1,3,o,16,9600,T510,1
1,0.0.0(@1,Zählernummer,,Meter_number,0
1,1.8.0(@1,Zählerstand,kWh,Total_in,3
1,21.7.0(@0.001,Leistung Phase 1,W,Power_L1,0
1,41.7.0(@0.001,Leistung Phase 2,W,Power_L2,0
1,61.7.0(@0.001,Leistung Phase 3,W,Power_L3,0
1,=m 4+5+6 @1,Leistung,W,Power_total,0
1,31.7.0(@1,Strom Phase 1,A,Current_L1,2
1,51.7.0(@1,Strom Phase 2,A,Current_L2,2
1,71.7.0(@1,Strom Phase 3,A,Current_L3,2
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,SGM,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100010801ff@1000,VerbrauchHT,kWh,E_inHT,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100020801ff@1000,EinspeisungHT,kWh,E_outHT,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h----
1,77070100240700FF@1,Leistung L1,W,PL1,0
1,77070100380700FF@1,Leistung L2,W,PL2,0
1,770701004C0700FF@1,Leistung L3,W,PL3,0
1,77070100200700ff@1,Voltage L1,V,Voltage,1
1,77070100340700ff@1,Voltage L2,V,Voltage_L2,1
1,77070100480700ff@1,Voltage L3,V,Voltage_L3,1
1,770701001f0700ff@1,Current L1,A,Current,2
1,77070100330700ff@1,Current L2,A,Current_L2,2
1,77070100470700ff@1,Current L3,A,Current_L3,2
1,77070100510701ff@1,Phaseangle L2-L1,deg,phase_angle_L2_L1,0
1,77070100510702ff@1,Phaseangle L3-L1,deg,phase_angle_L3_L1,0
1,77070100510704ff@1,Phaseangle I/U L1,deg,phase_angle_L1,1
1,7707010051070fff@1,Phaseangle I/U L2,deg,phase_angle_L2,1
1,7707010051071aff@1,Phaseangle I/U L3,deg,phase_angle_L3,1
1,770701000e0700ff@1,Frequency,Hz,Freq,1
1,77070100600100ff@#,Server-ID,,ID,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,SGM,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h----
1,77070100600100ff@#,Server-ID,,ID,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,SGM,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h----
1,77070100600100ff@#,Server-ID,,ID,0
#
>D
>B
->sensor53 r
>M 1
+1,3,o,16,9600,EHZ161,1
1,1-0:0.0.0*255(@#),Meter Number,,meter_number,0
1,1-0:1.8.0*255(@1,Verbrauch,kWh,Pin,4
1,1-0:2.8.0*255(@1,Einspeisung,kWh,Pout,4
1,1-0:32.7.0*255(@1,Volt_L1,V,volt_l1,2
1,1-0:52.7.0*255(@1,Volt_L2,V,volt_l2,2
1,1-0:72.7.0*255(@1,Volt_L3,V,volt_l3,2
1,1-0:31.7.0*255(@1,Ampere_L1,A,volt_l1,2
1,1-0:51.7.0*255(@1,Ampere_L2,A,volt_l2,2
1,1-0:71.7.0*255(@1,Ampere_L3,A,volt_l3,2
1,1-0:21.7.0*255(@1,Watt_L1,W,watt_l1,0
1,1-0:41.7.0*255(@1,Watt_L2,W,watt_l2,0
1,1-0:61.7.0*255(@1,Watt_L3,W,watt_l3,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,EHZ363,1
1,=so1,00010800,65,5,65,5,000f0700
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,770701000f0700ff@1,akt. Leistung2,W,Power2,0
1,77070100200700ff@1,Voltage L1,V,Volt_p1,1
1,77070100340700ff@1,Voltage L2,V,Volt_p2,1
1,77070100480700ff@1,Voltage L3,V,Volt_p3,1
1,770701001f0700ff@1,Amperage L1,A,Amperage_p1,1
1,77070100330700ff@1,Amperage L2,A,Amperage_p2,1
1,77070100470700ff@1,Amperage L3,A,Amperage_p3,1
1,77070100510704ff@1,Phaseangle I-L1/U-L1,deg,phase_angle_p1,1
1,7707010051070fff@1,Phaseangle I-L27I-L2,deg,phase_angle_p2,1
1,7707010051071aff@1,Phaseangle I-L3/I-L3,deg,phase_angle_p3,1
1,770701000e0700ff@1,Frequency,Hz,frequency,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,Hausheld-HBZ,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100600100ff@#,Zählernummer,,Wert,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,DTZ,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100200700ff@1,Voltage L1,V,volt_p1,1
1,77070100340700ff@1,Voltage L2,V,volt_p2,1
1,77070100480700ff@1,Voltage L3,V,volt_p3,1
1,770701001f0700ff@1,Amperage L1,A,amp_p1,1
1,77070100330700ff@1,Amperage L2,A,amp_p2,1
1,77070100470700ff@1,Amperage L3,A,amp_p3,1
1,77070100510701ff@1,Phase angle U-L2/U-L1,deg,phase_angle_l2_l1,1
1,77070100510702ff@1,Phase angle U-L3/U-L1,deg,phase_angle_l3_l1,1
1,77070100510704ff@1,Phase angle I-L1/U-L1,deg,phase_angle_p1,1
1,7707010051070fff@1,Phase angle I-L2/U-L2,deg,phase_angle_p2,1
1,7707010051071aff@1,Phase angle I-L3/U-L3,deg,phase_angle_p3,1
1,770701000e0700ff@1,Frequency,Hz,freq,0
1,77070100600100ff@#,Server ID,,server_id,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,EHZ,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100600100ff@#,Server ID,,server_id,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,Itron,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100600100ff@#,Zählernummer,,Wert,0
#
>D
res=0
scnt=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 80
scnt=0
ends
>M 1
+1,3,o,0,9600,Zähler,1
1,1-0:1.8.0(@1,Bezug,kWh,1-8-0,2
1,1-0:2.8.0(@1,Einspeisung,kWh,2-8-0,2
#
>D
>B
->sensor53 r
>M 1
+1,3,o,0,300,MT174,1,100,2F3F210D0A
1,1-0:1.8.0*255(@1,Total Consumed,kWh,Total_in,3
1,1-0:2.8.0*255(@1,Total Delivered,kWh,Total_out,3
1,1-0:0.0.0*255(@#),Meter Number,,Meter_number,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,MT175,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100240700ff@1,L1,W,L1,0
1,77070100380700ff@1,L2,W,L2,0
1,770701004C0700ff@1,L3,W,L3,0
1,77070100000009ff@#,Server_ID,,Server_ID,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,MT175,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,1
1,77070100010801ff@1000,Verbrauch_HT,kWh,E_in_HT,1
1,77070100010802ff@1000,Verbrauch_NT,kWh,E_in_NT,1
1,77070100020800ff@1000,Einspeisung,kWh,E_out,1
1,77070100100700ff@1,akt. Leistung,W,Power,18
1,=h--
1,77070100240700ff@1,L1,W,L1,18
1,77070100380700ff@1,L2,W,L2,18
1,770701004C0700ff@1,L3,W,L3,18
1,77070100000009ff@#,Server_ID,,Server_ID,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,MT176,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100240700ff@1,L1,W,L1,0
1,77070100380700ff@1,L2,W,L2,0
1,770701004C0700ff@1,L3,W,L3,0
1,77070100000009ff@#,Server_ID,,Server_ID,0
#
>D
res=0
scnt=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 80
scnt=0
ends
>M 1
+1,3,o,16,9600,MT382,1
1,1-0:1.8.0(@1,Bezug,kWh,1-8-0,2
1,1-0:2.8.0(@1,Einspeisung,kWh,2-8-0,2
1,1-0:1.7.0(@0.001,akt. Leistung,W,Power,3
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,MT631,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,MT681,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100240700ff@1,Current Consumption P1,W,Power_p1,0
1,77070100380700ff@1,Current Consumption P2,W,Power_p2,0
1,770701004c0700ff@1,Current Consumption P3,W,Power_p3,0
1,77070100000009ff@#,Service ID,,Meter_id,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,MT691,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100000009ff@#,Service ID,,Meter_id,0
#
>D
res=0
scnt=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 80
scnt=0
ends
>M 1
+1,3,o,0,9600,ACE6000,1
1,1-0:1.8.0(@1,Bezug,kWh,1-8-0,2
1,1-0:1.8.1(@1,Bezug HT,kWh,1-8-1,2
1,1-0:2.8.0(@1,Einspeisung,kWh,2-8-0,2
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,KAIFA,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100600100ff@#,Server-ID,,Meter_Number,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,16,9600,E220,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100600100ff@#,Server-ID,,Meter_Number,0
#
>D
res=0
scnt=0
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063034300D0A")
res=sml(1 0 4800)
case 200
scnt=0
ends
>M 1
+1,3,o,0,4800,E650,1
1,1-1:1.8.0(@1,Verbrauch,kWh,1-8-0,3
1,1-1:1.8.1(@1,Verbrauch NT,kWh,1-8-1,3
1,1-1:1.8.2(@1,Verbrauch HT,kWh,1-8-2,3
1,1-1:2.8.0@1,Einspeisung,kWh,2-8-0,3
1,1-1:2.8.1(@1,Einspeisung HT,kWh,2-8-1,3
1,1-1:2.8.2(@1,Einspeisung NT,kWh,2-8-2,3
1,1-1:1.5.0(@1,power_IN,kW,1-5-0,3
1,1-1:2.5.0(@1,power_OUT,kW,1-5-0,3
1,1-1:21.5.0(@1,power_L1,kW,21-5-0,3
1,1-1:41.5.0(@1,power_L2,kW,41-5-0,3
1,1-1:61.5.0(@1,power_L3,kW,61-5-0,3
1,1-1:32.7.0(@1,voltage_L1,V,32-7-0,2
1,1-1:52.7.0(@1,voltage_L2,V,52-7-0,2
1,1-1:72.7.0(@1,voltage_L3,V,72-7-0,2
1,1-1:31.7.0(@1,current_L1,A,31-7-0,3
1,1-1:51.7.0(@1,current_L2,A,51-7-0,3
1,1-1:71.7.0(@1,current_L3,A,71-7-0,3
1,1-1:91.7.0(@1,current_N,A,91-7-0,3
#
>D
scnt=0
res=0
>B
->sensor53 r
>F
scnt=scnt+1
switch scnt
;start after 1.6 seconds (16 x 100ms)
case 16
;set transfer speed to 300 baud
res=sml(1 0 300)
;trigger meter by sending 40 times 'NUL'
res=sml(1 1 "0000000000000000000000000000000000000000")
res=sml(1 1 "0000000000000000000000000000000000000000")
;followed by '/?! CR LF'
res=sml(1 1 "2F3F210D0A")
case 24
res=sml(1 1 "063033300D0A")
;set transfer speed to 2400 baud
res=sml(1 0 2400)
;restart sequence after 10 minutes (6000 x 100 ms)
case 6000
scnt=0
ends
>M 1
+1,3,o,0,2400,T550,1
1,=so2,0
1,6.8(@1,Zählerstand,MWh,mwh_count,3
1,6.6(@1,Max. Heizleistung,kWh,kwh_max_heatperf,1
1,6.26(@1,Durchlauf,m³,m3_throughput,2
1,6.33(@1,Max. Durchlauf per h,m³h,m3h_max_throughput,3
1,9.4(@1,Max. Temp. V-/R-Lauf,°C,c_max_temp_fb,1
#
>D
scnt=0
res=0
>B
->sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 50
scnt=0
ends
>M 1
+1,3,o,16,9600,E350,1
1,1.8.0(@1,Total Consumed,kWh,Total_in,3
1,2.8.0(@1,Total Delivered,kWh,Total_out,3
1,16.7(@1,Current power,kW,Power_in,2
1,C.1.0(@1,Server-ID,,Meter_number,0
#
>D
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 50
scnt=0
ends
>M 1
+1,3,o,16,9600,E230,1
1,1.8.0(@1,Total Consumed,kWh,Total_in,3
1,2.8.0(@1,Total Delivered,kWh,Total_out,3
1,16.7.0(@1,Current power,kW,Power_in,2
1,C.1.0(@1,Server-ID,,Meter_number,0
#
>D
>B
->sensor53 r
>M 1
+1,3,s,0,9600,L30,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
#
>D
res=0
scnt=0
>B
=>sensor53 r
>F
scnt+=1
switch scnt
case 6
res=sml(1 0 300)
res=sml(1 1 "2F3F210D0A")
case 18
res=sml(1 1 "063035300D0A")
case 20
res=sml(1 0 9600)
case 200
scnt=0
ends
>M 1
+1,3,o,0,9600,LK13BD,1
1,1.8.0(@1,Zaehlerstand,KWh,Total_in,3
#
>D
>B
=>sensor53 r
>M 1
+1,3,o,16,9600,LK13BE,1
1,1-0:1.8.0*255(@1,Gesamtverbrauch,kWh,total,3
1,1-0:1.8.0*96(@1,Verbrauch 1 Tag,kWh,total_1d,3
1,1-0:1.8.0*97(@1,Verbrauch 7 Tage,kWh,total_7d,3
1,1-0:1.8.0*98(@1,Verbrauch 30 Tage,kWh,total_30d,3
1,1-0:1.8.0*99(@1,Verbrauch 365 Tage,kWh,total_365d,3
1,1-0:16.7.0*255(@1,Verbrauch aktuell,W,current,0
1,1-0:2.8.0*255(@1,Gesamteinspeisung,kWh,total_out,3
1,1-0:32.7.0*255(@1,Spannung L1,V,voltage_l1,1
1,1-0:52.7.0*255(@1,Spannung L2,V,voltage_l2,1
1,1-0:72.7.0*255(@1,Spannung L3,V,voltage_l3,1
1,1-0:31.7.0*255(@1,Strom L1,A, amperage_l1,1
1,1-0:51.7.0*255(@1,Strom L2,A, amperage_l2,1
1,1-0:71.7.0*255(@1,Strom L3,A, amperage_l3,1
1,1-0:81.7.1*255(@1,UL2 zu UL1,deg,angle_ul2_ul1,0
1,1-0:81.7.2*255(@1,UL3 zu UL1,deg,angle_ul3_ul1,0
1,1-0:81.7.4*255(@1,IL1 zu UL1,deg,angle_il1_ul1,0
1,1-0:81.7.15*255(@1,IL2 zu UL2,deg,angle_il2_ul2,0
1,1-0:81.7.26*255(@1,IL3 zu UL3,deg,angle_il2_ul3,0
1,1-0:14.7.0*255(@1,Frequenz,Hz,frequency,1
#
>D
>B
->sensor53 r
>M 1
+1,3,s,16,9600,LK13BE,1
1,77070100010800ff@1000,Verbrauch,kWh,E_in,3
1,77070100020800ff@1000,Einspeisung,kWh,E_out,3
1,77070100100700ff@1,akt. Leistung,W,Power,0
1,=h--
1,77070100240700ff@1,Power L1,W,Power_L1_curr,0
1,77070100380700ff@1,Power L2,W,Power_L2_curr,0
1,770701004C0700ff@1,Power L3,W,Power_L3_curr,0
1,77070100200700ff@1,Voltage L1,V,Volt_L1_curr,1
1,77070100340700ff@1,Voltage L2,V,Volt_L2_curr,1
1,77070100480700ff@1,Voltage L3,V,Volt_L3_curr,1
1,770701001f0700ff@1,Amperage L1,A,Amperage_L1_curr,2
1,77070100330700ff@1,Amperage L2,A,Amperage_L2_curr,2
1,77070100470700ff@1,Amperage L3,A,Amperage_L3_curr,2
1,770701000e0700ff@1,Frequency,Hz,HZ,2
1,77070100510704ff@1,Phaseangle I-L1/U-L1,deg,phase_angle_p1,1
1,7707010051070fff@1,Phaseangle I-L2/I-L2,deg,phase_angle_p2,1
1,7707010051071aff@1,Phaseangle I-L3/I-L3,deg,phase_angle_p3,1
1,77070100510701ff@1,Phase angle U-L2/U-L1,deg,phase_angle_l2_l1,1
1,77070100510702ff@1,Phase angle U-L3/U-L1,deg,phase_angle_l3_l1,1
#
>D
>B
=>sensor53 r
>M 1
+1,3,r,0,9600,Home,1
1,=so3,256
1,=so4,KEY
1,020909x14UUuuUUuu@1000,Zählerstand,kWh,Zaehlerstand,2
1,020909x34UUuuUUuu@1000,Bezug aktuell,kwh,Bezug,3
1,020909x24UUuuUUuu@1000,BL Bezug,kvarh,BL_Bezug,3
1,020909x19UUuuUUuu@1000,Einspeisung Gesamt,kWh,Einspeisung_ges,2
1,020909x39UUuuUUuu@1000,Einspeisung aktuell ,kW,Einspeisung_akt,3
1,020909x29UUuuUUuu@1000,BL Einspeisung,kvarh,BL_Einspeisung,3
1,020909x19UUuu@1,year,,year,0
1,020909x21ss@1,month,,month,0
1,020909x22ss@1,day,,day,0
1,020909x24ss@1,hh,,hh,0
1,020909x25ss@1,mm,,mm,0
1,020909x26ss@1,ss,,ss,0
1,020909x32UUuuUUuu@1000,+A,kWh,+A,3
1,020909x37UUuuUUuu@1000,-A,kWh,-A,3
1,020909x42UUuuUUuu@1000,+R,varh,+R,3
1,020909x47UUuuUUuu@1000,-R,varh,-R,3
1,020909x52UUuuUUuu@1,+P,W,+P,3
1,020909x57UUuuUUuu@1,-P,W,-P,3
1,020909x62UUuuUUuu@1,+Q,var,+Q,3
1,020909x67UUuuUUuu@1,-Q,var,-Q,3
#
>D
>B
->sensor53 r
>M 1
+1,3,o,0,300,STROM,1,600,2F3F210D0A
1,1.8.1(@1,Total Consumed,kWh,Total_in,3
1,2.8.1(@1,Total Delivered,kWh,Total_out,3
1,0.0.0(@#),Meter Number,,Meter_number,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,0,9600,Strom,1
1,77070100010800ff@1000,Bezug,kWh,Total_in,0
1,77070100020800ff@1000,Einspeisung,kWh,Total_out,0
#
>D
>B
=>sensor53 r
>M 1
+1,3,s,0,9600,SML,1
1,77070100010800ff@1000,Total Verbrauch,kWh,Total_in,3
1,77070100020800ff@1000,Total Einspeisung,kWh,Total_out,3
1,=h==================
1,77070100100700ff@1,Actual load,W,Power_curr,0
1,=h==================
1,=m 9+10+11 @1,Currents L1+L2+L3,A,Curr_summ,3
1,=m 12+13+14/#3 @1,Voltage L1+L2+L3/3,V,Volt_avg,3
1,=h==================
1,77070100240700ff@1,Consumption P1,W,Power_p1,2
1,77070100380700ff@1,Consumption P2,W,Power_p2,2
1,770701004c0700ff@1,Consumption P3,W,Power_p3,2
1,=h ----
1,770701001f0700ff@1,Current L1,A,Curr_p1,3
1,77070100330700ff@1,Current L2,A,Curr_p2,3
1,77070100470700ff@1,Current L3,A,Curr_p3,3
1,=h ----
1,77070100200700ff@1,Voltage L1,V,Volt_p1,3
1,77070100340700ff@1,Voltage L2,V,Volt_p2,3
1,77070100480700ff@1,Voltage L3,V,Volt_p3,3
1,=h==================
1,77070100510701ff@1,Phaseangle L2-L1,deg,phase_angle_L2_L1,0
1,77070100510702ff@1,Phaseangle L3-L1,deg,phase_angle_L3_L1,0
1,77070100510704ff@1,Phaseangle I/U L1,deg,phase_angle_L1,1
1,7707010051070fff@1,Phaseangle I/U L2,deg,phase_angle_L2,1
1,7707010051071aff@1,Phaseangle I/U L3,deg,phase_angle_L3,1
1,770701000e0700ff@1,Frequency,Hz,Freq,1
;1,=h=======UNBEKANNT===========
;1,77070100000009FF@#,unbekannt1,,Power_Use_Sum,3
;1,77070100000000FF@#,unbekannt2,,Power_Use_Sum,3
;1,7707010060320101@#,unbekannt3,,Meter_id,0
;1,77010b0a01445a47@#,unbekannt4,,Meter_id,0
;1,77070100600100ff@#,unbekannt5,,Meter_id,0
1,=h
#