Symptom: No heating
Procedure:
Check demand - Room stat
Check taps - dripping
Check thermistors
Check safety / low pressure
Check diverter valve
Check electrics
Check pump
Check rads
Symptom: No hot water (Heating ok)
Procedure:
Turn tap on (water ok) try other taps too
Flow sensor (check)
Check preheat (if it has one)
PCB faulty Pre-lim checks
Gas rate/Burner pressure
Check diverter valve (check microswitch)
Pump should be ok
Fan should be ok
Burner should be ok
Check heat sensing thermistor (resistance)
High flame comes on (modureg) - visual
Symptom: Neither heating nor hot water
Procedure:
Any power to boiler (Powercut/fuse)
Any gas to boiler (supply to meter)
Does boiler fire up?
Potentiometer fault (no call for demand)
Flow switch faulty
Diverter valve faulty (microswitch not working)
Pump faulty (not running)
Overheat stat tripped (reset)
Pump, heat exchanger blocked/ faulty thermistor
Fan (not running - air pressure switch)
Faulty PCB
Flame rectification / spark electrodes
Faulty gas valve (solenoid not opening to allow gas through)
Symptom: User unhappy with system poor performance
Procedure:
Check performance (Flow cup/Heat Rise)
Check inlet gas pressure
Burner pressure/Gas rate
Check thermostats, potentiometers, thermistors
Fan speed (modulating boilers only)
Pump failure
Scaled up heat exchanger & plate heat exchanger
Faulty gas valve
Faulty modulating solenoid on valve
Possible controls/PCB fault