A.T.U. CG3000
ALCUNI ANNI OR SONO VENNI IN POSSESSO DI QUESTO "BUON" ACCORDATORE MA.....DA RIPARARE.
LA CASA MADRE DICE CHE TALE A.T.U. PUO' SOPPORTARE 200 WATTS KEY DOWN MASSIMI.
L'ULTIMO PROPRIETARIO ERRONEAMENTE GLI AVEVA APPLICATO BEN 300 WATTS E UNA
DELLE CAPACITA' POSTA IN ACCORDO SULL' USCITA ERA "PARTITA".
PROSEGUENDO LA LETTURA VEDREMO ALCUNE RIPARAZIONI E MODIFICHE DI QUESTO A.T.U.
IL CG3000 EFFETTUA CORRETTAMENTE RAPIDI ACCORDI SE SI RISPETTANO ALCUNE AVVERTENZE:
-UTILIZZARE ANTENNE (FILARI/VERTICALI...) CHE NON RISUONINO A 1/2 ONDA ALLA FREQ. IN USO.
-USARE UN BUON SISTEMA DI CONTRAPPESO (TERRA) COSTITUITO DA PIU' PICCHETTI DISTANZIATI.
-IN FASE DI ACCORDO NON UTILIZZAR E PIU' DI 10/15 WATTS OUT.
QUESTO A.T.U. E' DOTATO DELLA POSSIBILITA' DI MEMORIZZARE BEN 200 FREQUENZE.
E PUO' ACCORDARE "AEREI" DA 1,6 A 30 MHZ A SECONDA DELLA LORO LUNGHEZZA MINIMA.
ALIMENTANDOLO A 13,8 Vcc IL SUO CONSUMO RISULTA < DI 0.8 Amp.
E' INOLTRE DOTATO DI UNA "UNITA' DI CONTROLLO" OPT. CHE SERVE UNICAMENTE A VISIONARE
L'AVVENUTO ACCORDO E PER CANCELLARE I 200 CAMPI DI MEMORIA.
INFO "UNIT CONTROL" ---->
VISTO IL SUO COSTO ECCESSIVO SUL MERCATO....L'AUTOCOSTRUZIONE ( UNIT CONTROL ) CONVIENE
ANCHE IN QUESTO CASO.
ECCO ALCUNI LINK A RIGUARDO : LINK 1 LINK 2 LINK 3
SE IL CG 3000 SI HA INTENZIONE DI UTILIZZARLO ALL' ESTERNO, SENZA ULTERIORI PROTEZIONI SE
NON CON IL SUO CONTENITORE STAGNO (???),SI PUO' ANDARE INCONTRO AD INFILTRAZIONI DI
ACQUA AL SUO INTERNO. TALE PROBLEMATICA E' SPESSO RICORRENTE DOPO LUNGA ESPOSIZIONE
DELL'A.T.U. AGLI U.V.A. (RAGGI ULTRAVIOLETTI). VEDI ---->
IO HO SCELTO DI TOGLIERE LA SCHEDA DEL CG 3000 DAL SUO CONTENITORE E INSERIRLO IN UNO A
MIO DIRE MOLTO PIU' ADATTO PER ESPOSIZIONE ALL'ESTERNO.
IN OGNI CASO AL CONTENITORE SCELTO, E' SEMPRE MEGLIO DARGLI UNA PROTEZIONE ULTERIORE E
PRATICARE UN PICCOLO FORO (2.5 mm) NELLA PARTE INFERIORE DEL BOX,PER FAR DEFLUIRE LA
EVENTUALE CONDENSA CHE SI PUO' CREARE AL SUO INTERNO.
PER ADATTARE L'ACCORDATORE AL NUOVO CONTENITORE HO DOVUTO EFFETTUARE ALCUNE MOD's
PER MEGLIO INSERIRLO AL SUO INTERNO.
NUOVO CONTENITORE STAGNO PER CG 3000
IL MORSETTO CHE SI VEDE POSTERIORMENTE ALLA SCATOLA E' STATO FISSATO TRAMITE COLLANTE
ADATTO PER METALLO/PLASTICA.
I SIGILLANTI SONO DEL TIPO ADATTO AI PIU' VARI MATERIALI PLASTICI.
I PERNI (INOX DA 6 mm) ANTENNA( SUP.) E TERRA(INF.) SONO PASSANTI IN MORSETTI PASSA-CAVO.
HO DOVUTO "SMUSSARE" GLI ANGOLI DELLA SCHEDA PER MEGLIO ADATTARLA AL NUOVO BOX.
ALL'INTERNO DELL'A.T.U. VERSO L' RTX E' STATO INSERITO UN R.F. CHOKE AVVOLTO SU FT 140 -43.
COME PRECEDENTEMENTE DICEVO...SE SI OLTREPASSA LA MAX PWR APPLICABILE ALL' A.T.U. PUO'
SICURAMENTE ACCADERE LA ROTTURA DELLE CAPACITA' IN USCITA DI ACCORDO. IN FASE DI SOSTI-
TUZIONE E' MEGLIO SCEGLIERE IL COMPONENTE DI PARI CAPACITA' MA CON TENSIONE MAGGIORE.
IO HO SOSTITUITO LA CAPACITA' INTERESSATA CON UNA DA 6 Kv.
CON IL PASSARE DEL TEMPO LE CONTINUE COMMUTAZIONI E IL PASSAGGIO DI R.F. TROPPO ELEVATO
IN FASE DI ACCORDO, SI CONSIGLIA ACCORDARE CON 10/15 WATTS MAX, INCIDONO SULLA DURATA
DEI RELE' SPECIE QUELLI POSTI IN USCITA.
IL LORO GUASTO E' PRINCIPALMENTE MECCANICO...ED E' EVIDENZIATO DA PROBLEMI IN ACCORDO E
SPESSO CON EVIDENTI SCARICHE R.F. SUL CIRCUITO STAMPATO E INTERNAMENTE AL CONTENITORE.
I RELE' ORIGINALI SIGLATI IKE HRM3-S SONO INTERSCAMBIABILI CON I HF-36F OPPURE JZC-36F
PIU' FACILMENTE RINTRACCIABILI IN INTERNET A COSTI CONTENUTI.
LE LORO CARATTERISTICHE ELETTRICHE SONO :
TENSIONE & CORRENTE MAX DEL CONTATTO----> 250Vac/30Vdc 10 AMPERE
ALIMENTAZIONE E VALORE IN OHM DELLA BOBINA BOBINA AGGANCIO----> 12Vcc // 530 ohm
ESISTONO ANCHE MODELLI DI RELE' I QUALI CONTATTI SOPPORTANO PIU' INTENSITA' DI CORRENTE:
HF 36F https://www.hongfa.com/Product/Item/380 ( 10 amp.)
HF36F-W https://www.hongfa.com/Product/Item/551 ( 16 amp.)
HF36F-20 https://www.hongfa.com/Product/Item/775 ( 20 amp.)
SI SCONSIGLIA DI UTILIZZARE ALTRE TIPOLOGIE DI RELE' PER NON CREARE INVASIVE MODIFICHE
AL CIRCUITO STAMPATO DEL CG3000.
LINKs PER ORDINARE I RELE':
https://it.aliexpress.com/item/32776462555.html
https://it.aliexpress.com/item/32854873317.html
IN OGNI CASO SI PRESENTI UN GUASTO ANCHE AD UN SINGOLO RELE' E' CONVENIENTE,VISTO IL BASSO COSTO,SOSTITUIRE TUTTA LA SERIE DEI RELE' DELLA SERIE HRM3-S ( SERIE GRANDE ).
RELE' INTERSCAMBIABILE CON IKE HRM3-S
SIGLE DEL RELE' IN FOTOGRAFIA ( made in china ) :
O12-HS = TENSIONE ALIMENTAZIONE BOBINA RELE'
10A 250VAC/30VDC = MAX CORRENTE & MAX TENSIONE DEL CONTATTO INT. DEL RELE'
TV-5 = SIGLA RICONOSCIMENTO DEL RELE' (NORMALMENTE IN USO SUI CIRCUITI TELEVISIVI (TV))
A SEGUIRE UN LINK A RIGUARDO E FOTO ILLUSTRATIVE SUL PROBLEMA DEI RELE'
LINK ----->
SI NOTA LA "SFIAMMATA" R.F. NEL BOX RELE' IN FASE DI SOSTITUZIONE
ULTERIORE SOSTITUZIONE RELE' AL CG3000 (AGOSTO 2020)
ALTRI GUASTI DI QUESTO A.T.U. IN CUI SONO INCAPPATO RIGUARDANO LA COMPONENTISTICA DI DIODI E CAPACITA'.
DIFFICILMENTE RIGUARDANO I VARI I.C. E MEMORIE PRESENTI NEL CIRCUITO.
PRESUMO CHE TALE INCONVENIENTE POSSA ESSERE CAUSATO DA UN INGRESSO DI R.F. TROPPO ELEVATO IN FASE DI
ACCORDO (+- 100WATTS) E TROPPO PROLUNGATO COME TEMPO IN PRESENZA DI R.O.S.
L'INCONVENIENTE CHE SI PRESENTA E' CHE NESSUN ACCORDO E' PIU' POSSIBILE....NESSUN RELE' SI ECCITA TRANNE
QUELLO DI ALIMENTAZIONE AL MOMENTO DELL'ACCENSIONE DELL'A.T.U.
ECOO ALCUNE IMMAGINI DEI POSSIBILI GUASTI A RIGUARDO:
CAPACITA' SMD (10 NF 50 VL) E DIODO (1N4148) POSTO AL DI SOTTO DA SOSTITUIRE.
INOLTRE PISTA DA C (10 NF) E R (12.K) DA RIPRISTINARE.
RIPARAZIONE EFFETTUATA SENZA SMONTARE IL CIRCUITO DALLO CHASSIS. (AGOSTO 2020)
ESISTENDO DIFFERENTI MODELLI DI CG3000...HO ANCHE RISCONTRATO CHE PIU' DIODI FOSSERO IN "CORTO".
I DIODI INTERESSATI SONO QUASI SEMPRE QUELLI POSTI IN PROSSIMITA' DEL TRASFORMATORE TOROIDALE E LE
RESISTENZE DA 50 OHM.
OLTRE ALL A CAPACITA' C53 (10 NF/ 50VL) E' STATO NECESSARIO SOSTITUIRE I DIODI
D5/D6/D7 NORMALISSIMI 1N4148 RISULTATI IN "CORTO".
C53 RISULTA COLLEGATO:
UN CAPO TRA R54 E IL CATODO DI D6 ...E L'ALTO CAPO VERSO MASSA.
AVVERTENZA:
D8 E D9 RISULTANO COLLEGATI IN MODO "CLIPPER" EFFETTUANDO EVENTUALI MISURE CON UN MULTIMETRO RISULTEREBBERO IN "CORTO".
SPERO DI ESSERE STATO ESAUSTIVO SU QUESTE SEMPLICI PROBLEMATICHE (RISOLVIBILI) CHE PUO' AVERE L' A.T.U. CG 3000.
LE RIPARAZIONI E MODIFICHE QUI DESCRITTE SONO DI FACILE REALIZZAZIONE.
MA IN OGNI CASO DECLINO QUALSIASI MIA RESPONSABILITA' PER EVENTUALI DANNI A COSE E/O A PERSONE
PER INTERVENTI EFFETTUATI DA PERSONALE TECNICO NON QUALIFICATO.
VY 73 de ARMANDO