Rockwell Testing
Principal of the Rockwell Test
Principal of the Rockwell Test
The indenter moves down into position on the part surface
A minor load is applied and a zero reference position is established
The major load is applied for a specified time period (dwell time) beyond zero
The major load is released leaving the minor load applied
The resulting Rockwell number represents the difference in depth from the zero reference position as a result of the application of the major load.