Acetone
Alcohol
Ammonia
Butane - 1.9% and 19,000 ppm
Gasoline - 1.4% and 14,000 ppm
Halon
Hydrogen
Jet Fuel
Ethylene Oxide
Methane - 5% and 5,000 ppm
Natural Gas - 2% and 2,000 ppm
Propane - 2.1% and 2,100 ppm
Refrigerants
Solvents
*Air fresheners and laundry detergents/softeners may effect Sensit readings. Double-check a positive 'click' in laundry rooms.*
Temperature Range
-4°F to 122°F (-20°C to 50°C)
Battery
Alkaline Battery
~30 Hour Run-Time
Weight and Dimensions
1.2 lbs (544 g)
11.5” x 3.0” x 2.2” (29.2 cm x 7.6 cm x 5.9 cm)
Sensor Specifications
Type Resolution Range Accuracy
LEL 0.1% to 2% 0-100% LEL ±10%
PPM 1 or 10 ppm 0-50,000 ppm ±10%
Gas Range Resolution
LEL 0-100% 1%
O₂ 0-30% 0.1%
CO 0-1999 ppm 1 ppm
H₂S 0-200 ppm 1 ppm
LEL
Alarms
LO 10%
HI 20%
CO
10%
12,500 ppm
NH₃ (Ammonia)
10%
1,500 ppm
Pentane
10%
1,500 ppm
H₂S (Hydrogen Sulfide)
10%
4,000 ppm
HCN (Hydrogen Cyanide)
10%
5,600 ppm
O₂
Alarms
LO <19.5%
HI >23.0%
20.9% - Safe/Normal
23% - High Fire Danger
19.5% - IDLH
CO
Alarms
LO 50 ppm
HI 100 ppm
SCBA >50 ppm
Ventilate >20 ppm
1-35 ppm - PEL/TLV (8 Hours a Day over 20 Years)
50-200 ppm - Ventilate (Elevated/High Risk for Occupancies)
400-500 ppm - Severe Exposure Symptoms
>1,200 ppm - IDLH
H₂S
1-5 ppm - Rotten Egg Smell/Headache and Airway Problems
10-20 ppm - Sweet Smell/Nausea, Dizziness, Severe Headache
50-100 ppm - Eye Irritation, Loss of Smell, Drowsiness, Dry Mouth
200-300 ppm - IDLH/Severe Respiratory Illness and Severe Headache
>500 ppm - Collapse, Unconsciousness, Death
Durability
25 ft. (7.5 m) Drop Protection
MIL-STD-810G Drop Protection
Certified IP68 Rating
Operating Temperature Range
-40°F to 140°F (-40°C to 60°C)
Relative Humidity
5% - 95% Intermittent
15% - 90% Non-Condensing
Battery
Rechargeable Li-Polymer Battery
20 Hour Run-Time
< 4 Hour Charge Time
Weight and Dimensions
4.4“ x 3.0” x 1.4” (11 cm x 7.6 cm x 3.5 cm)
8 oz (228 g)
Datalogging
> 50 hours (adjustable)
> 500 event logs
Energy Range (Gamma)
25 keV - 3 MeV
Gamma Spectrum
1024 channels; 3 MeV
Gamma Sensitivity (Cs-137, CsI)
2.1 cps/urem/h
Dose Rate/Accuracy (Cs-137)
≤100 nSv/h – 250 μSv/h (≤10μRem/h – 25 mRem/h); ±20%
Typical Resolution
≤7.5 % FWHM at 662 keV
Battery
Internal Single Cell Li-ion - ≥ 36 Hour Battery Life
Replaceable Back-Up CR-123A - ≥18 Hour Battery Life
Recharge Time ≤ 6 Hours
Startup Time is < 2 Minutes
Operating Temperature Range
-22°F to 122°F (-30°C to 50°C)
Weight and Dimensions
≤ 0.88 lb (0.4 kg)
5.7" x 2.2" x 1.9" (14.5 cm x 5.6 cm x 4.8 cm)
Temperature Measurement Range
-40°F to 1,022°F
Operating Temperature Range
32°F to 120°F
Battery
12 Hours Battery Life
Laser Distance to Size on Target Ratio
12:1
Response Time
500 mSec (95% of Reading)
CL (Chlorine)
290°F Becomes a Gas
Flammable at 300°F
NH₃ (Ammonia)
1,200°F Ignition Point
FP (Hydraulic Fluid)
300°F to 600°F
Auto Ignition at 500°F to 700°F
All Documents and Specifications per Manufactures.