Running the static structural analysis of Pulley Support to assess the safety of the design. A pulley support made of cast alloy steel is fixed (bolted) at the flat surface through the three bolt holes located at the base of the support. The part is subjected to bearing force of 100 lbs applied to the inner surface of the larger cylinder in + X – direction. In addition to that a downward force of 20 lbs representing the weight of other part (not shown) is applied to the top face of cylinder.
The Pulley Support-pulley support is safe t use under the condition of constrain and load assigned to it because the factor of Safety equal to 4.636 which is greater than 1.
The steady state analysis of Heat sink with heat load of 50 watts and a constant convection coefficient of 100 W/m2 Degree C due to force convection of air flow in cooling the system.
Heat sink is made of Aluminum Alloy – 2014 Alloy