Small Sample SHIELD-on Protocol

Reagents / Equipment Required

Overview

For smaller PFA-fixed samples, the SHIELD protocol deviates from the standard protocol.  In the standard protocol, samples are incubated in SHIELD-OFF Solution to allow diffusion of epoxy into the sample before it is transferred to SHIELD-ON to crosslink the epoxy.  When small samples are transferred to SHIELD-ON, the epoxy can potentially diffuse out of the sample before it is cross-linked (due to their size). 

In this protocol, we start with a mixture of the SHIELD-ON buffer and the epoxy to prevent diffusion when the sample is transferred to pure SHIELD-ON. 

[Note] If you store the SHIELD-Epoxy in the freezer, you will need to take it out before performing SHIELD to thaw. Alternatively you can aliquot some in advance and store it at 4°C  as a shorter term storage option.

Protocol

Before proceeding, please check the Expiration Date on the SHIELD-Epoxy bottle. If the solution is used after the expiration date the mechanical stability of the sample can be compromised. Also, once you begin the next step, you should not stop the process until SHIELD fixation is completed, so make sure to plan ahead. 

SHIELD OFF

[Note] The following SHIELD-ON steps should ONLY be used for any sample with its smallest dimension 500 um - 1.5 mm or smaller. 

SHIELD ON

SHIELD post-fixation is now complete. The sample can be stored in 1X PBS with 0.02% sodium azide at 4°C for several months without significant loss of fluorescence signal and structural integrity. 

You may now proceed to the delipidation section of the protocol.