Overview of Status of Analysis, Design, Fabrication, Tests, etc.
Testing: One last test to determine calibration coefficients to input in flow meter.
Fabrication: Final mounting devices sent to Greg to be 3D printed
Poster: Draft finished, awaiting comments.
Final Report: Revisions made based on peer edits.
Accomplishments from Previous Week
Tested out 2 different 3D printed mounting devices and adjusted for a final mounting device design.
Performed testing of 6 different pipes of varying diameters and thicknesses with the mounting devices.
Determined 0.5 inch diameter with 0.2 inch thickness was most accurate and ideal.
Goals for This Week (list names after each item). Use specific and measurable objectives.
Ascertain if current CMA housing will hold the new flow meters (Jun)
3D print and assemble the final mounting devices (Scott & Zeeshan)
Research digital filtering (Becky)
Sponsor Comments from Last Meeting and Actions Taken to Address these Comments
Focus on putting together a final prototype - in progress.
Hinge not necessary on mounting device - completely new mounting device designed.
Instructor Comments from Last Meeting and Actions Taken to Address these Comments
Helical inserts instead of screws - will purchase as soon as final mounting devices are printed and usable.
Digital filtering - Becky is researching and is in charge of filtering
Risks and Areas of Concern
Flow meter will not fit into current housing [310 mm (length) x 145 mm (width) x 165 mm (high)]
Resources or Information Required but not Available
n/a
Schedule
Week 10
Determine if flow meter will fit into current housing (Tues.)
Assemble final 3D printed mounting devices (Wed.)
Final calibration test on 0.5 in. diameter and 0.2 in. thickness stainless steel pipe with final mounting devices (Tues. & Wed.)
Presentation to sponsors (Thurs.)
Finals Week
Poster Presentation (Wed.)
Budget (list amount spent and amount remaining)
Spent: $60
Remaining: $940
Progress on Report and Webpage
Report revised as per comments from peer review. Waiting for final calibration data to determine slope and y-intercept coefficients.
Webpage all up to date.